Effects of Sigh on Regional Lung Strain and Ventilation Heterogeneity in Acute Respiratory Failure Patients Undergoing Assisted Mechanical Ventilation.

Tommaso Mauri1, Nilde Eronia, Chiara Abbruzzese, Roberto Marcolin, Andrea Coppadoro, Savino Spadaro, Nicolo' Patroniti, Giacomo Bellani, Antonio Pesenti.   

Abstract

OBJECTIVE: In acute respiratory failure patients undergoing pressure support ventilation, a short cyclic recruitment maneuver (Sigh) might induce reaeration of collapsed lung regions, possibly decreasing regional lung strain and improving the homogeneity of ventilation distribution. We aimed to describe the regional effects of different Sigh rates on reaeration, strain, and ventilation heterogeneity, as measured by thoracic electrical impedance tomography.
DESIGN: Prospective, randomized, cross-over study.
SETTING: General ICU of a single university-affiliated hospital. PATIENTS: We enrolled 20 critically ill patients intubated and mechanically ventilated with PaO2/FIO2 up to 300 mm Hg and positive end-expiratory pressure at least 5 cm H2O (15 with acute respiratory distress syndrome), undergoing pressure support ventilation as per clinical decision.
INTERVENTIONS: Sigh was added to pressure support ventilation as a 35 cm H2O continuous positive airway pressure period lasting 3-4 seconds at different rates (no-Sigh vs 0.5, 1, and 2 Sigh(s)/min). All study phases were randomly performed and lasted 20 minutes.
MEASUREMENTS AND MAIN RESULTS: In the last minutes of each phase, we measured arterial blood gases, changes in end-expiratory lung volume of nondependent and dependent regions, tidal volume reaching nondependent and dependent lung (Vtnondep and Vtdep), dynamic intratidal ventilation heterogeneity, defined as the average ratio of Vt reaching nondependent/Vt reaching dependent lung regions along inspiration (VtHit). With Sigh, oxygenation improved (p < 0.001 vs no-Sigh), end-expiratory lung volume of nondependent and dependent regions increased (p < 0.01 vs no-Sigh), Vtnondep showed a trend to reduction, and Vtdep significantly decreased (p = 0.11 and p < 0.01 vs no-Sigh, respectively). VtHit decreased only when Sigh was delivered at 0.5/min (p < 0.05 vs no-Sigh), while it did not vary during the other two phases.
CONCLUSIONS: Sigh decreases regional lung strain and intratidal ventilation heterogeneity. Our study generates the hypothesis that in ventilated acute respiratory failure patients, Sigh may enhance regional lung protection.

Entities:  

Mesh:

Year:  2015        PMID: 25985386     DOI: 10.1097/CCM.0000000000001083

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  21 in total

1.  What's new in electrical impedance tomography.

Authors:  Tommaso Mauri; Alain Mercat; Giacomo Grasselli
Journal:  Intensive Care Med       Date:  2018-10-04       Impact factor: 17.440

2.  Sigh maneuver protects healthy lungs during mechanical ventilation in adult Wistar rats.

Authors:  Andréa Cristiane Lopes da Silva; Natália Alves de Matos; Ana Beatriz Farias de Souza; Thalles de Freitas Castro; Leandro da Silva Cândido; Michel Angelo das Graças Silva Oliveira; Guilherme de Paula Costa; André Talvani; Sílvia Dantas Cangussú; Frank Silva Bezerra
Journal:  Exp Biol Med (Maywood)       Date:  2020-07-08

Review 3.  Spontaneous breathing: a double-edged sword to handle with care.

Authors:  Tommaso Mauri; Barbara Cambiaghi; Elena Spinelli; Thomas Langer; Giacomo Grasselli
Journal:  Ann Transl Med       Date:  2017-07

Review 4.  Ventilator-induced Lung Injury.

Authors:  Jeremy R Beitler; Atul Malhotra; B Taylor Thompson
Journal:  Clin Chest Med       Date:  2016-10-14       Impact factor: 2.878

5.  Using injury cost functions from a predictive single-compartment model to assess the severity of mechanical ventilator-induced lung injuries.

Authors:  Michelle M Mellenthin; Siyeon A Seong; Gregory S Roy; Elizabeth Bartolák-Suki; Katharine L Hamlington; Jason H T Bates; Bradford J Smith
Journal:  J Appl Physiol (1985)       Date:  2019-05-02

6.  Quantifying unintended exposure to high tidal volumes from breath stacking dyssynchrony in ARDS: the BREATHE criteria.

Authors:  Jeremy R Beitler; Scott A Sands; Stephen H Loring; Robert L Owens; Atul Malhotra; Roger G Spragg; Michael A Matthay; B Taylor Thompson; Daniel Talmor
Journal:  Intensive Care Med       Date:  2016-06-24       Impact factor: 17.440

7.  The Association Between Ventilator Dyssynchrony, Delivered Tidal Volume, and Sedation Using a Novel Automated Ventilator Dyssynchrony Detection Algorithm.

Authors:  Peter D Sottile; David Albers; Carrie Higgins; Jeffery Mckeehan; Marc M Moss
Journal:  Crit Care Med       Date:  2018-02       Impact factor: 7.598

8.  From Big Data to Artificial Intelligence: Harnessing Data Routinely Collected in the Process of Care.

Authors:  Barret Rush; David J Stone; Leo Anthony Celi
Journal:  Crit Care Med       Date:  2018-02       Impact factor: 7.598

9.  Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography.

Authors:  Tommaso Mauri; Nilde Eronia; Cecilia Turrini; Marta Battistini; Giacomo Grasselli; Roberto Rona; Carlo Alberto Volta; Giacomo Bellani; Antonio Pesenti
Journal:  Intensive Care Med       Date:  2016-08-12       Impact factor: 17.440

10.  Optimum support by high-flow nasal cannula in acute hypoxemic respiratory failure: effects of increasing flow rates.

Authors:  Tommaso Mauri; Laura Alban; Cecilia Turrini; Barbara Cambiaghi; Eleonora Carlesso; Paolo Taccone; Nicola Bottino; Alfredo Lissoni; Savino Spadaro; Carlo Alberto Volta; Luciano Gattinoni; Antonio Pesenti; Giacomo Grasselli
Journal:  Intensive Care Med       Date:  2017-07-31       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.