Literature DB >> 25984796

A geometrical model for the Monte Carlo simulation of the TrueBeam linac.

M Rodriguez1, J Sempau, A Fogliata, L Cozzi, W Sauerwein, L Brualla.   

Abstract

Monte Carlo simulation of linear accelerators (linacs) depends on the accurate geometrical description of the linac head. The geometry of the Varian TrueBeam linac is not available to researchers. Instead, the company distributes phase-space files of the flattening-filter-free (FFF) beams tallied at a plane located just upstream of the jaws. Yet, Monte Carlo simulations based on third-party tallied phase spaces are subject to limitations. In this work, an experimentally based geometry developed for the simulation of the FFF beams of the Varian TrueBeam linac is presented. The Monte Carlo geometrical model of the TrueBeam linac uses information provided by Varian that reveals large similarities between the TrueBeam machine and the Clinac 2100 downstream of the jaws. Thus, the upper part of the TrueBeam linac was modeled by introducing modifications to the Varian Clinac 2100 linac geometry. The most important of these modifications is the replacement of the standard flattening filters by ad hoc thin filters. These filters were modeled by comparing dose measurements and simulations. The experimental dose profiles for the 6 MV and 10 MV FFF beams were obtained from the Varian Golden Data Set and from in-house measurements performed with a diode detector for radiation fields ranging from 3  ×  3 to 40  ×  40 cm(2) at depths of maximum dose of 5 and 10 cm. Indicators of agreement between the experimental data and the simulation results obtained with the proposed geometrical model were the dose differences, the root-mean-square error and the gamma index. The same comparisons were performed for dose profiles obtained from Monte Carlo simulations using the phase-space files distributed by Varian for the TrueBeam linac as the sources of particles. Results of comparisons show a good agreement of the dose for the ansatz geometry similar to that obtained for the simulations with the TrueBeam phase-space files for all fields and depths considered, except for the 40  ×  40 cm(2) field where the ansatz geometry was able to reproduce the measured dose more accurately. Our approach overcomes some of the limitations of using the Varian phase-space files. It makes it possible to: (i) adapt the initial beam parameters to match measured dose profiles; (ii) reduce the statistical uncertainty to arbitrarily low values; and (iii) assess systematic uncertainties (type B) by using different Monte Carlo codes. One limitation of using phase-space files that is retained in our model is the impossibility of performing accurate absolute dosimetry simulations because the geometrical description of the TrueBeam ionization chamber remains unknown.

Mesh:

Year:  2015        PMID: 25984796     DOI: 10.1088/0031-9155/60/11/N219

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

Review 1.  Monte Carlo systems used for treatment planning and dose verification.

Authors:  Lorenzo Brualla; Miguel Rodriguez; Antonio M Lallena
Journal:  Strahlenther Onkol       Date:  2016-11-25       Impact factor: 3.621

2.  X-ray-induced acoustic computed tomography for guiding prone stereotactic partial breast irradiation: a simulation study.

Authors:  Yue Zheng; Pratik Samant; Jack Merill; Yong Chen; Salahuddin Ahmad; Dengwang Li; Liangzhong Xiang
Journal:  Med Phys       Date:  2020-06-15       Impact factor: 4.071

3.  Monte Carlo evaluation of target dose coverage in lung stereotactic body radiation therapy with flattening filter-free beams.

Authors:  Oleg N Vassiliev; Christine B Peterson; Joe Y Chang; Radhe Mohan
Journal:  J Radiother Pract       Date:  2020-10-16

4.  A Monte Carlo Study of Photon Beam Characteristics on Various Linear Accelerator Filters.

Authors:  Pawiro S A; Azzi A; Soejoko D S
Journal:  J Biomed Phys Eng       Date:  2020-10-01

5.  Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode.

Authors:  Zhongsu Feng; Haizhen Yue; Yibao Zhang; Hao Wu; Jinsheng Cheng; Xu Su
Journal:  Radiat Oncol       Date:  2016-02-27       Impact factor: 3.481

6.  Validation of PRIMO Monte Carlo Model of Clinac®iX 6MV Photon Beam.

Authors:  B Sarin; B Bindhu; B Saju; Raguram K Nair
Journal:  J Med Phys       Date:  2020-03-13

7.  Comparison of Air-Gaps Effect in a Small Cavity on Dose Calculation for 6 MV Linac.

Authors:  A Azzi; D Ryangga; S A Pawiro
Journal:  J Biomed Phys Eng       Date:  2021-02-01

8.  PRIMO Monte Carlo software benchmarked against a reference dosimetry dataset for 6 MV photon beams from Varian linacs.

Authors:  Marcelino Hermida-López; David Sánchez-Artuñedo; Juan Francisco Calvo-Ortega
Journal:  Radiat Oncol       Date:  2018-08-07       Impact factor: 3.481

9.  Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.

Authors:  Boram Lee; Seonghoon Jeong; Kwangzoo Chung; Myonggeun Yoon; Hee Chul Park; Youngyih Han; Sang Hoon Jung
Journal:  J Appl Clin Med Phys       Date:  2019-09-23       Impact factor: 2.102

10.  MLC parameters from static fields to VMAT plans: an evaluation in a RT-dedicated MC environment (PRIMO).

Authors:  Lucia Paganini; Giacomo Reggiori; Antonella Stravato; Valentina Palumbo; Pietro Mancosu; Francesca Lobefalo; Anna Gaudino; Antonella Fogliata; Marta Scorsetti; Stefano Tomatis
Journal:  Radiat Oncol       Date:  2019-12-02       Impact factor: 3.481

View more