Literature DB >> 25983838

Screw loosening and Migration after Dynesys Implantation.

Min Jae Cho1, Chun Kee Chung1, Chi Heon Kim1.   

Abstract

Due to the problems associated with rigid fixation, the concept of dynamic stabilization was introduced. Dynesys is one of the pedicle screw-based dynamic stabilization systems. In spite of the dynamic nature of Dynesys, there are concerns about the rigidity of the Dynesys system. We present a case of vertebral body split fracture after Dynesys implantation in a 74-year-old woman. She had undergone L2-L5 laminectomy and Dynesys implantation for spinal stenosis 15 months ago. She was discharged with improvement in lower back pain and claudication. Follow-up X-ray images were taken at 1, 3 and 6 months and there was no evidence of screw migration. During the follow-up period, she received selective root block due to persistent leg pain. Eight months after the operation, she visited our hospital due to severe lower back pain. Magnetic resonance imaging showed the features of lumbar spondylitis from L2 to L5. Plain X-ray and computed tomography images showed the presence of a superiorly migrated screw at L5. The screws migrated superiorly into the intervertebral disc space creating a bony defect resembling a sagittal migrated fracture. The Dynesys system was removed and lumbar spondylitis was treated with antibiotics. The aim of the present case was to demonstrate the problems caused due to rigidity of the Dynesys system, when postoperative infection occurs after Dynesys implantation.

Entities:  

Keywords:  Dynesys; Infection; Screw loosening & migration

Year:  2012        PMID: 25983838      PMCID: PMC4431025          DOI: 10.14245/kjs.2012.9.3.300

Source DB:  PubMed          Journal:  Korean J Spine        ISSN: 1738-2262


  15 in total

1.  Influence of Dynesys system screw profile on adjacent segment and screw.

Authors:  Chien-Lin Liu; Zheng-Cheng Zhong; Shih-Liang Shih; Chinghua Hung; Yong-Eng Lee; Chen-Sheng Chen
Journal:  J Spinal Disord Tech       Date:  2010-08

2.  Preclinical evaluation of the Dynesys posterior spinal stabilization system: a nonhuman primate model.

Authors:  Bryan W Cunningham; John M Dawson; Nianbin Hu; Seok Woo Kim; Paul C McAfee; Steven L Griffith
Journal:  Spine J       Date:  2010-05-21       Impact factor: 4.166

3.  Dynesys fixation for lumbar spine degeneration.

Authors:  Matthias Bothmann; Erich Kast; Gerald Jens Boldt; Joachim Oberle
Journal:  Neurosurg Rev       Date:  2007-09-29       Impact factor: 3.042

Review 4.  Screw loosening after posterior dynamic stabilization--review of the literature.

Authors:  T Kocak; B Cakir; H Reichel; T Mattes
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2010-04       Impact factor: 0.531

5.  The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system.

Authors:  Thomas M Stoll; Gilles Dubois; Othmar Schwarzenbach
Journal:  Eur Spine J       Date:  2002-09-10       Impact factor: 3.134

6.  Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years.

Authors:  Dieter Grob; Arnoldo Benini; Astrid Junge; Anne F Mannion
Journal:  Spine (Phila Pa 1976)       Date:  2005-02-01       Impact factor: 3.468

7.  Dynamic stabilization for degenerative lumbar scoliosis in elderly patients.

Authors:  Mario Di Silvestre; Francesco Lolli; Georgios Bakaloudis; Patrizio Parisini
Journal:  Spine (Phila Pa 1976)       Date:  2010-01-15       Impact factor: 3.468

Review 8.  Diagnosis and treatment of osteoporosis.

Authors:  Mary Gayle Sweet; Jon M Sweet; Michael P Jeremiah; Sim S Galazka
Journal:  Am Fam Physician       Date:  2009-02-01       Impact factor: 3.292

9.  Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization.

Authors:  Stefan Schaeren; Ivan Broger; Bernhard Jeanneret
Journal:  Spine (Phila Pa 1976)       Date:  2008-08-15       Impact factor: 3.468

10.  Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis.

Authors:  Klaus John Schnake; Stefan Schaeren; Bernard Jeanneret
Journal:  Spine (Phila Pa 1976)       Date:  2006-02-15       Impact factor: 3.468

View more
  2 in total

1.  Lateral Lumbar Interbody Fusion and in Situ Screw Fixation for Rostral Adjacent Segment Stenosis of the Lumbar Spine.

Authors:  Young Hoon Choi; Shin Won Kwon; Jung Hyeon Moon; Chi Heon Kim; Chun Kee Chung; Sung Bae Park; Won Heo
Journal:  J Korean Neurosurg Soc       Date:  2017-10-25

2.  Efficacy of Antibiotic-Loaded Cement Augmentation for Correcting Low Grade Pedicle Screw Loosening.

Authors:  Chi Ho Kim; Chang Il Ju; Sung Myung Lee; Seok Won Kim
Journal:  Korean J Neurotrauma       Date:  2021-03-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.