Literature DB >> 12384741

The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system.

Thomas M Stoll1, Gilles Dubois, Othmar Schwarzenbach.   

Abstract

Various forms of lumbar instability require a surgical stabilization. As an alternative to fusion, a mobile, dynamic stabilization restricting segmental motion would be advantageous in various indications, allowing greater physiological function and reducing the inherent disadvantages of rigid instrumentation and fusion. The dynamic neutralization system for the spine (Dynesys) is a pedicle screw system for mobile stabilization, consisting of titanium alloy screws connected by an elastic synthetic compound, controlling motion in any plane (non-fusion system). This prospective, multi-center study evaluated the safety and efficacy of Dynesys in the treatment of lumbar instability conditions, evaluating pre- and post-operative pain, function, and radiological data on a consecutive series of 83 patients. Indications consisted of unstable segmental conditions, mainly combined with spinal stenosis (60.2%) and with degenerative discopathy (24.1%), in some cases with disc herniation (8.4%), and with revision surgery (6.0%). Thirty-nine patients additionally had degenerative spondylolisthesis, and 30 patients had undergone previous lumbar surgery. In 56 patients instrumentation was combined with direct decompression. The mean age at operation was 58.2 (range 26.8-85.3) years; the mean follow-up time was 38.1 months (range 11.2-79.1 months). There were nine complications unrelated to the implant, and one due to a screw malplacement. Four of them required an early surgical reintervention. Additional lumbar surgery in the follow-up period included: implant removal and conversion into spinal fusion with rigid instrumentation for persisting pain in three cases, laminectomy of an index segment in one case and screw removal due to loosening in one case. In seven cases, radiological signs of screw loosening were observed. In seven cases, adjacent segment degeneration necessitated further surgery. Mean pain and function scores improved significantly from baseline to follow-up, as follows: back pain scale from 7.4 to 3.1, leg pain scale from 6.9 to 2.4, and Oswestry Disability Index from 55.4% to 22.9%. These study results compare well with those obtained by conventional procedures; in addition to which, mobile stabilization is less invasive than fusion. Long-term screw fixation is dependent on correct screw dimension and proper screw positioning. The natural course of polysegmental disease in some cases necessitates further surgery as the disease progresses. Dynamic neutralization proved to be a safe and effective alternative in the treatment of unstable lumbar conditions.

Entities:  

Mesh:

Year:  2002        PMID: 12384741      PMCID: PMC3611570          DOI: 10.1007/s00586-002-0438-2

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  93 in total

1.  Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spine.

Authors:  Antonius Rohlmann; Thomas Zander; Georg Bergmann; Hadi N Boustani
Journal:  Eur Spine J       Date:  2011-10-20       Impact factor: 3.134

2.  Dynamic stabilization adjacent to single-level fusion: part I. Biomechanical effects on lumbar spinal motion.

Authors:  Patrick Strube; Stephan Tohtz; Eike Hoff; Christian Gross; Carsten Perka; Michael Putzier
Journal:  Eur Spine J       Date:  2010-08-04       Impact factor: 3.134

3.  [Long-term results of the Dynesys implant].

Authors:  C Klöckner
Journal:  Orthopade       Date:  2010-06       Impact factor: 1.087

4.  Posterior dynamic stabilization of the lumbar spine with the Accuflex rod system as a stand-alone device: experience in 20 patients with 2-year follow-up.

Authors:  Alejandro Reyes-Sánchez; Barón Zárate-Kalfópulos; Isabel Ramírez-Mora; Luis Miguel Rosales-Olivarez; Armando Alpizar-Aguirre; Guadalupe Sánchez-Bringas
Journal:  Eur Spine J       Date:  2010-05-22       Impact factor: 3.134

5.  The effect of design parameters of dynamic pedicle screw systems on kinematics and load bearing: an in vitro study.

Authors:  C Schilling; S Krüger; T M Grupp; G N Duda; W Blömer; A Rohlmann
Journal:  Eur Spine J       Date:  2010-11-26       Impact factor: 3.134

6.  [Dynamic posterior stabilization with the pedicle screw system DYNESYS®].

Authors:  Othmar Schwarzenbach; Ulrich Berlemann
Journal:  Oper Orthop Traumatol       Date:  2010-11       Impact factor: 1.154

7.  Survivorship analysis of 150 consecutive patients with DIAM™ implantation for surgery of lumbar spinal stenosis and disc herniation.

Authors:  Yoo-Joon Sur; Chae-Gwan Kong; Jong-Beom Park
Journal:  Eur Spine J       Date:  2010-10-17       Impact factor: 3.134

8.  Hybrid Surgery Combined with Dynamic Stabilization System and Fusion for the Multilevel Degenerative Disease of the Lumbosacral Spine.

Authors:  Soo Eon Lee; Tae-Ahn Jahng; Hyun Jib Kim
Journal:  Int J Spine Surg       Date:  2015-08-28

9.  Short-term effects of a dynamic neutralization system (Dynesys) for multi-segmental lumbar disc herniation.

Authors:  Qi Wang; Jun Liu; Ying Shi; Yu Chen; Hailong Yu; Junxiong Ma; Weijian Ren; Huifeng Yang; Hongwei Wang; Liangbi Xiang
Journal:  Eur Spine J       Date:  2015-11-17       Impact factor: 3.134

10.  A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1-year results.

Authors:  J F Zucherman; K Y Hsu; C A Hartjen; T F Mehalic; D A Implicito; M J Martin; D R Johnson; G A Skidmore; P P Vessa; J W Dwyer; S Puccio; J C Cauthen; R M Ozuna
Journal:  Eur Spine J       Date:  2003-12-19       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.