Literature DB >> 2597069

Variability of depth measurements of the optic nerve head and peripapillary retina with computerized image analysis.

L Dandona1, H A Quigley, H D Jampel.   

Abstract

Computerized topographic mapping of 10 repeated fundus images of one eye each in 10 healthy subjects and in 10 subjects with elevated intraocular pressures (IOPs) was performed with the Humphrey Retinal Analyzer. The variability of depth measurements at 400 to 650 individual locations in the optic nerve head and peripapillary retina was evaluated. The average size of the 95% confidence intervals for individual depth measurements for healthy subjects and those with elevated IOPs were 166 and 232 microns in the optic nerve head and 205 and 261 microns in the peripapillary retina, respectively. Variability was significantly less for healthy subjects than for those with elevated IOPs. Variability was significantly greater for depth measurements in the peripapillary retina than for measurements in the optic head. Knowledge about variability of individual depth measurements is useful for proper interpretation of computerized topographic mapping to detect retinal nerve fiber damage.

Entities:  

Mesh:

Year:  1989        PMID: 2597069     DOI: 10.1001/archopht.1989.01070020868029

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  7 in total

1.  Comparison between laser scanning tomography and computerised image analysis of the optic disc.

Authors:  A Azuara-Blanco; G L Spaeth; J Nicholl; I M Lanzl; J J Augsburger
Journal:  Br J Ophthalmol       Date:  1999-03       Impact factor: 4.638

2.  Topographic changes in the optic disc in eyes with cotton-wool spots and primary open-angle glaucoma.

Authors:  E Chihara; Y Honda
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

3.  Reproducibility of topographic measures of the glaucomatous optic nerve head.

Authors:  O Geyer; A Michaeli-Cohen; D M Silver; D Versano; M Neudorfer; R Dzhanov; M Lazar
Journal:  Br J Ophthalmol       Date:  1998-01       Impact factor: 4.638

4.  Optic disc measurement: a comparison of indirect ophthalmoscopic methods.

Authors:  A F Spencer; S A Vernon
Journal:  Br J Ophthalmol       Date:  1995-10       Impact factor: 4.638

5.  Performance of two films for densitometry of retinal photographs.

Authors:  R Eikelboom; R Cooper; C Barry
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1993-09       Impact factor: 3.117

6.  Optic disc measurement with the Zeiss four mirror contact lens.

Authors:  A F Spencer; S A Vernon
Journal:  Br J Ophthalmol       Date:  1994-10       Impact factor: 4.638

7.  Clinical results of implantation of the Chirila keratoprosthesis in rabbits.

Authors:  C R Hicks; T V Chirila; A B Clayton; J H Fitton; S Vijayasekaran; P D Dalton; X Lou; S Platten; B Ziegelaar; Y Hong; G J Crawford; I J Constable
Journal:  Br J Ophthalmol       Date:  1998-01       Impact factor: 4.638

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.