Literature DB >> 25959974

Rapid multicomponent relaxometry in steady state with correction of magnetization transfer effects.

Fang Liu1, Walter F Block1, Richard Kijowski2, Alexey Samsonov1,2.   

Abstract

PURPOSE: To study the effects of magnetization transfer (MT) on multicomponent T2 parameters obtained using mcDESPOT in macromolecule-rich tissues and to propose a new method called mcRISE to correct MT-induced biases.
METHODS: The two-pool mcDESPOT model was modified by the addition of an exchanging macromolecule proton pool to model the MT effect in cartilage. The mcRISE acquisition scheme was developed to provide sensitivity to all pools. An incremental fitting was applied to estimate MT and relaxometry parameters with minimized coupling. The interaction between MT and relaxometry parameters, efficacy of MT correction, and feasibility of mcRISE in vivo were investigated in simulations and in healthy volunteers.
RESULTS: The MT effect caused significant errors in multicomponent T1/T2 values and in fast-relaxing water fraction fF , which is consistent with previous experimental observations. fF increased significantly with macromolecule content if MT was ignored. mcRISE resulted in a multifold reduction of MT biases and yielded decoupled multicomponent T1/T2 relaxometry and quantitative MT parameters.
CONCLUSION: mcRISE is an efficient approach for correcting MT biases in multicomponent relaxometry based on steady state sequences. Improved specificity of mcRISE may help to elucidate the sources of the previously described high sensitivity of noncorrected mcDESPOT parameters to disease-related changes in cartilage and the brain.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  cartilage imaging; magnetization transfer; multicomponent relaxometry; steady-state sequences

Mesh:

Year:  2015        PMID: 25959974      PMCID: PMC4637271          DOI: 10.1002/mrm.25672

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  50 in total

1.  T1, T2 relaxation and magnetization transfer in tissue at 3T.

Authors:  Greg J Stanisz; Ewa E Odrobina; Joseph Pun; Michael Escaravage; Simon J Graham; Michael J Bronskill; R Mark Henkelman
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

2.  On the origin of apparent low tissue signals in balanced SSFP.

Authors:  O Bieri; K Scheffler
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

3.  High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI).

Authors:  Sean C L Deoni
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

4.  MT effects and T1 quantification in single-slice spoiled gradient echo imaging.

Authors:  Xiawei Ou; Daniel Frank Gochberg
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

5.  Quantitative magnetization transfer imaging using balanced SSFP.

Authors:  M Gloor; K Scheffler; O Bieri
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

6.  Transverse relaxation time (T2) mapping in the brain with off-resonance correction using phase-cycled steady-state free precession imaging.

Authors:  Sean C L Deoni
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

7.  SSFP signal with finite RF pulses.

Authors:  Oliver Bieri; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2009-11       Impact factor: 4.668

8.  In vivo measurement of T2 distributions and water contents in normal human brain.

Authors:  K P Whittall; A L MacKay; D A Graeb; R A Nugent; D K Li; D W Paty
Journal:  Magn Reson Med       Date:  1997-01       Impact factor: 4.668

9.  Multicomponent T2 relaxation analysis in cartilage.

Authors:  David A Reiter; Ping-Chang Lin; Kenneth W Fishbein; Richard G Spencer
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

10.  Gleaning multicomponent T1 and T2 information from steady-state imaging data.

Authors:  Sean C L Deoni; Brian K Rutt; Tarunya Arun; Carlo Pierpaoli; Derek K Jones
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more
  19 in total

1.  Analysis of White Matter Damage in Patients with Multiple Sclerosis via a Novel In Vivo MR Method for Measuring Myelin, Axons, and G-Ratio.

Authors:  A Hagiwara; M Hori; K Yokoyama; M Nakazawa; R Ueda; M Horita; C Andica; O Abe; S Aoki
Journal:  AJNR Am J Neuroradiol       Date:  2017-08-03       Impact factor: 3.825

2.  Incorporation of nonzero echo times in the SPGR and bSSFP signal models used in mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-09-26       Impact factor: 4.668

3.  Multicomponent T2 analysis of articular cartilage with synovial fluid partial volume correction.

Authors:  Fang Liu; Rajeev Chaudhary; Walter F Block; Alexey Samsonov; Richard Kijowski
Journal:  J Magn Reson Imaging       Date:  2015-10-05       Impact factor: 4.813

4.  Rapid simultaneous high-resolution mapping of myelin water fraction and relaxation times in human brain using BMC-mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Neuroimage       Date:  2016-10-08       Impact factor: 6.556

5.  Clinical high-resolution mapping of the proteoglycan-bound water fraction in articular cartilage of the human knee joint.

Authors:  Mustapha Bouhrara; David A Reiter; Kyle W Sexton; Christopher M Bergeron; Linda M Zukley; Richard G Spencer
Journal:  Magn Reson Imaging       Date:  2017-06-20       Impact factor: 2.546

6.  Biexponential T2 relaxation estimation of human knee cartilage in vivo at 3T.

Authors:  Azadeh Sharafi; Gregory Chang; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2017-05-31       Impact factor: 4.813

7.  Simultaneous multi-angular relaxometry of tissue with MRI (SMART MRI): Theoretical background and proof of concept.

Authors:  Alexander L Sukstanskii; Jie Wen; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2016-03-15       Impact factor: 4.668

8.  Deep learning-based fully automatic segmentation of wrist cartilage in MR images.

Authors:  Ekaterina Brui; Aleksandr Y Efimtcev; Vladimir A Fokin; Remi Fernandez; Anatoliy G Levchuk; Augustin C Ogier; Alexey A Samsonov; Jean P Mattei; Irina V Melchakova; David Bendahan; Anna Andreychenko
Journal:  NMR Biomed       Date:  2020-05-11       Impact factor: 4.044

9.  Improved determination of the myelin water fraction in human brain using magnetic resonance imaging through Bayesian analysis of mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Neuroimage       Date:  2015-10-22       Impact factor: 6.556

10.  Phase-based T2 mapping with gradient echo imaging.

Authors:  Xiaoke Wang; Diego Hernando; Scott B Reeder
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.