Literature DB >> 27729276

Rapid simultaneous high-resolution mapping of myelin water fraction and relaxation times in human brain using BMC-mcDESPOT.

Mustapha Bouhrara1, Richard G Spencer2.   

Abstract

A number of central nervous system (CNS) diseases exhibit changes in myelin content and magnetic resonance longitudinal, T1, and transverse, T2, relaxation times, which therefore represent important biomarkers of CNS pathology. Among the methods applied for measurement of myelin water fraction (MWF) and relaxation times, the multicomponent driven equilibrium single pulse observation of T1 and T2 (mcDESPOT) approach is of particular interest. mcDESPOT permits whole brain mapping of multicomponent T1 and T2, with data acquisition accomplished within a clinically realistic acquisition time. Unfortunately, previous studies have indicated the limited performance of mcDESPOT in the setting of the modest signal-to-noise range of high-resolution mapping, required for the depiction of small structures and to reduce partial volume effects. Recently, we showed that a new Bayesian Monte Carlo (BMC) analysis substantially improved determination of MWF from mcDESPOT imaging data. However, our previous study was limited in that it did not discuss determination of relaxation times. Here, we extend the BMC analysis to the simultaneous determination of whole-brain MWF and relaxation times using the two-component mcDESPOT signal model. Simulation analyses and in-vivo human brain studies indicate the overall greater performance of this approach compared to the stochastic region contraction (SRC) algorithm, conventionally used to derive parameter estimates from mcDESPOT data. SRC estimates of the transverse relaxation time of the long T2 fraction, T2,l, and the longitudinal relaxation time of the short T1 fraction, T1,s, clustered towards the lower and upper parameter search space limits, respectively, indicating failure of the fitting procedure. We demonstrate that this effect is absent in the BMC analysis. Our results also showed improved parameter estimation for BMC as compared to SRC for high-resolution mapping. Overall we find that the combination of BMC analysis and mcDESPOT, BMC-mcDESPOT, shows excellent performance for accurate high-resolution whole-brain mapping of MWF and bi-component transverse and longitudinal relaxation times within a clinically realistic acquisition time. Published by Elsevier Inc.

Entities:  

Keywords:  Brain; High-resolution mapping; MRI; Myelin water fraction; Relaxation times

Mesh:

Year:  2016        PMID: 27729276      PMCID: PMC5303643          DOI: 10.1016/j.neuroimage.2016.09.064

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  99 in total

1.  In vivo multi-slice mapping of myelin water content using T2* decay.

Authors:  Dosik Hwang; Dong-Hyun Kim; Yiping P Du
Journal:  Neuroimage       Date:  2010-04-14       Impact factor: 6.556

2.  Comparison of myelin water fraction from multiecho T2 decay curve and steady-state methods.

Authors:  Jing Zhang; Shannon H Kolind; Cornelia Laule; Alex L MacKay
Journal:  Magn Reson Med       Date:  2014-02-11       Impact factor: 4.668

3.  Compensation of diffusion effects in T2 measurements.

Authors:  R Deichmann; H Adolf; E Kuchenbrod; U Nöth; C Schwarzbauer; A Haase
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

4.  Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology.

Authors:  C Laule; E Leung; D K B Lis; A L Traboulsee; D W Paty; A L MacKay; G R W Moore
Journal:  Mult Scler       Date:  2006-12       Impact factor: 6.312

5.  Assessment of magnetization transfer effects in myocardial tissue using balanced steady-state free precession (bSSFP) cine MRI.

Authors:  Oliver M Weber; Peter Speier; Klaus Scheffler; Oliver Bieri
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

6.  One component? Two components? Three? The effect of including a nonexchanging "free" water component in multicomponent driven equilibrium single pulse observation of T1 and T2.

Authors:  Sean C L Deoni; Lucy Matthews; Shannon H Kolind
Journal:  Magn Reson Med       Date:  2012-08-22       Impact factor: 4.668

7.  Estimating the age of healthy infants from quantitative myelin water fraction maps.

Authors:  Douglas C Dean; Jonathan O'Muircheartaigh; Holly Dirks; Nicole Waskiewicz; Katie Lehman; Lindsay Walker; Irene Piryatinsky; Sean C L Deoni
Journal:  Hum Brain Mapp       Date:  2015-01-30       Impact factor: 5.038

8.  Multi-compartment T2 relaxometry using a spatially constrained multi-Gaussian model.

Authors:  Ashish Raj; Sneha Pandya; Xiaobo Shen; Eve LoCastro; Thanh D Nguyen; Susan A Gauthier
Journal:  PLoS One       Date:  2014-06-04       Impact factor: 3.240

9.  Whole brain myelin mapping using T1- and T2-weighted MR imaging data.

Authors:  Marco Ganzetti; Nicole Wenderoth; Dante Mantini
Journal:  Front Hum Neurosci       Date:  2014-09-02       Impact factor: 3.169

10.  Brain and cord myelin water imaging: a progressive multiple sclerosis biomarker.

Authors:  Shannon Kolind; Arshia Seddigh; Anna Combes; Bretta Russell-Schulz; Roger Tam; Vignan Yogendrakumar; Sean Deoni; Naomi A Sibtain; Anthony Traboulsee; Steven C R Williams; Gareth J Barker; Peter A Brex
Journal:  Neuroimage Clin       Date:  2015-10-03       Impact factor: 4.881

View more
  30 in total

1.  Rapid B1 field mapping at 3 T using the 180° signal null method with extended flip angle.

Authors:  Abinand C Rejimon; Diana Y Lee; Christopher M Bergeron; You Zhuo; Wenshu Qian; Richard G Spencer; Mustapha Bouhrara
Journal:  Magn Reson Imaging       Date:  2018-06-26       Impact factor: 2.546

Review 2.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

3.  A simple and fast adaptive nonlocal multispectral filtering algorithm for efficient noise reduction in magnetic resonance imaging.

Authors:  Mustapha Bouhrara; Michael C Maring; Richard G Spencer
Journal:  Magn Reson Imaging       Date:  2018-08-24       Impact factor: 2.546

4.  Spatially adaptive unsupervised multispectral nonlocal filtering for improved cerebral blood flow mapping using arterial spin labeling magnetic resonance imaging.

Authors:  Mustapha Bouhrara; Diana Y Lee; Abinand C Rejimon; Christopher M Bergeron; Richard G Spencer
Journal:  J Neurosci Methods       Date:  2018-08-18       Impact factor: 2.390

5.  Evidence of demyelination in mild cognitive impairment and dementia using a direct and specific magnetic resonance imaging measure of myelin content.

Authors:  Mustapha Bouhrara; David A Reiter; Christopher M Bergeron; Linda M Zukley; Luigi Ferrucci; Susan M Resnick; Richard G Spencer
Journal:  Alzheimers Dement       Date:  2018-04-19       Impact factor: 21.566

6.  Fisher information and Cramér-Rao lower bound for experimental design in parallel imaging.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2017-11-01       Impact factor: 4.668

7.  Steady-state double-angle method for rapid B1 mapping.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2019-03-03       Impact factor: 4.668

8.  Adult brain aging investigated using BMC-mcDESPOT-based myelin water fraction imaging.

Authors:  Mustapha Bouhrara; Abinand C Rejimon; Luis E Cortina; Nikkita Khattar; Christopher M Bergeron; Luigi Ferrucci; Susan M Resnick; Richard G Spencer
Journal:  Neurobiol Aging       Date:  2019-10-14       Impact factor: 4.673

9.  Volumetric imaging of myelin in vivo using 3D inversion recovery-prepared ultrashort echo time cones magnetic resonance imaging.

Authors:  Ya-Jun Ma; Adam C Searleman; Hyungseok Jang; Shu-Juan Fan; Jonathan Wong; Yanping Xue; Zhenyu Cai; Eric Y Chang; Jody Corey-Bloom; Jiang Du
Journal:  NMR Biomed       Date:  2020-07-20       Impact factor: 4.044

10.  Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE) MRI Sequence in Multiple Sclerosis.

Authors:  Ya-Jun Ma; Hyungseok Jang; Zhao Wei; Zhenyu Cai; Yanping Xue; Roland R Lee; Eric Y Chang; Graeme M Bydder; Jody Corey-Bloom; Jiang Du
Journal:  Radiology       Date:  2020-08-11       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.