Literature DB >> 19780160

SSFP signal with finite RF pulses.

Oliver Bieri1, Klaus Scheffler.   

Abstract

The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP signal description for use with finite RF pulses. In this paper, finite RF pulse effects on balanced SSFP signal formation are analyzed as a function of the RF time, the pulse repetition time, the flip angle (alpha) and relaxation times (T(1,2)). The observed signal modulations from finite RF pulses (compared to infinitesimal ones) can range from only a few percent (for RF time/pulse repetition time << 1, alpha << 90 degrees, T(2)/T(1) approximately 1) to over 10% (for RF time/pulse repetition time << 1, alpha approximately 90 degrees, T(2)/T(1) << 1) and may even exceed 100% in the limit of RF time/pulse repetition time --> 1 (for alpha approximately 90 degrees, T(2)/T(1) << 1). As a result, a revision of SSFP signal theory is indicated not only for reasons of completeness but also seems advisable, e.g., for all quantitative SSFP methods. A simple modification for the common balanced SSFP equation is derived that provides an accurate framework for SSFP signal description over a wide variety of practical and physiologic parameters. (c) 2009 Wiley-Liss, Inc.

Mesh:

Year:  2009        PMID: 19780160     DOI: 10.1002/mrm.22116

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Incorporation of nonzero echo times in the SPGR and bSSFP signal models used in mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-09-26       Impact factor: 4.668

2.  Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit.

Authors:  Neville D Gai; John A Butman
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

3.  Strategies for improved 3D small-tip fast recovery imaging.

Authors:  Hao Sun; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2013-10-11       Impact factor: 4.668

4.  Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

Authors:  Dan Ma; Simone Coppo; Yong Chen; Debra F McGivney; Yun Jiang; Shivani Pahwa; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2017-01-11       Impact factor: 4.668

5.  Balanced SSFP-like steady-state imaging using small-tip fast recovery with a spectral prewinding pulse.

Authors:  Hao Sun; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2015-03-29       Impact factor: 4.668

6.  Optimizing MR Scan Design for Model-Based ${T}_{1}$ , ${T}_{2}$ Estimation From Steady-State Sequences.

Authors:  Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2016-10-04       Impact factor: 10.048

7.  Spectrally selective three-dimensional dynamic balanced steady-state free precession for hyperpolarized C-13 metabolic imaging with spectrally selective radiofrequency pulses.

Authors:  Hong Shang; Subramaniam Sukumar; Cornelius von Morze; Robert A Bok; Irene Marco-Rius; Adam Kerr; Galen D Reed; Eugene Milshteyn; Michael A Ohliger; John Kurhanewicz; Peder E Z Larson; John M Pauly; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2016-10-21       Impact factor: 4.668

8.  Modified Look-Locker T1 evaluation using Bloch simulations: human and phantom validation.

Authors:  Neville D Gai; Christian Stehning; Marcelo Nacif; David A Bluemke
Journal:  Magn Reson Med       Date:  2012-03-27       Impact factor: 4.668

9.  Radial fast interrupted steady-state (FISS) magnetic resonance imaging.

Authors:  Ioannis Koktzoglou; Robert R Edelman
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

10.  Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

Authors:  Sydney N Williams; Jon-Fredrik Nielsen; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2017-07-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.