Literature DB >> 25955869

Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.

Iscander M Maissan1, Perjan J A C Dirven1, Iain K Haitsma2, Sanne E Hoeks1, Diederik Gommers3, Robert Jan Stolker1.   

Abstract

OBJECT: Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) is known to be an accurate monitor of elevated intracranial pressure (ICP). However, it is yet unknown whether fluctuations in ICP result in direct changes in ONSD. Therefore, the authors researched whether ONSD and ICP simultaneously change during tracheal manipulation in patients in the intensive care unit (ICU) who have suffered a traumatic brain injury (TBI). MATERIALS: The authors included 18 ICP-monitored patients who had sustained TBI and were admitted to the ICU. They examined the optic nerve sheath by performing ultrasound before, during, and after tracheal manipulation, which is known to increase ICP. The correlation between ONSD and ICP measurements was determined, and the diagnostic performance of ONSD measurement was tested using receiver operating characteristic curve analysis.
RESULTS: In all patients ICP increased above 20 mm Hg during manipulation of the trachea, and this increase was directly associated with a dilation of the ONSD of > 5.0 mm. After tracheal manipulation stopped, ICP as well as ONSD decreased immediately to baseline levels. The correlation between ICP and ONSD was high (R(2) = 0.80); at a cutoff of ≥ 5.0 mm ONSD, a sensitivity of 94%, a specificity of 98%, and an area under the curve of 0.99 (95% CI 0.97-1.00) for detecting elevated ICP were determined.
CONCLUSIONS: In patients who have sustained a TBI, ultrasonography of the ONSD is an accurate, simple, and rapid measurement for detecting elevated ICP as well as immediate changes in ICP. Therefore, it might be a useful tool to monitor ICP, especially in conditions in which invasive ICP monitoring is not available, such as at trauma scenes.

Entities:  

Keywords:  ICP = intracranial pressure; ICU = intensive care unit; ONSD; ONSD = optic nerve sheath diameter; TBI = traumatic brain injury; TCD = transcranial Doppler; diagnostic and operative techniques; head trauma; intracranial pressure; neurotrauma; optic nerve sheath; trauma

Mesh:

Year:  2015        PMID: 25955869     DOI: 10.3171/2014.10.JNS141197

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  43 in total

1.  Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure.

Authors:  Ashish Agrawal; Roger Cheng; Julin Tang; Debbie Y Madhok
Journal:  Crit Care Med       Date:  2019-06       Impact factor: 7.598

Review 2.  Noninvasive methods of detecting increased intracranial pressure.

Authors:  Wen Xu; Patrick Gerety; Tomas Aleman; Jordan Swanson; Jesse Taylor
Journal:  Childs Nerv Syst       Date:  2016-06-28       Impact factor: 1.475

Review 3.  Non-invasive detection of intracranial pressure related to the optic nerve.

Authors:  Jian Li; Chao Wan
Journal:  Quant Imaging Med Surg       Date:  2021-06

4.  Novel Radiographic Assessment of the Cribriform Plate.

Authors:  Kimia G Ganjaei; Zachary M Soler; Elliott D Mappus; Robert J Taylor; Mitchell L Worley; Jennifer K Mulligan; Jose L Mattos; Nicholas R Rowan; Guilherme J M Garcia; Judy R Dubno; Mark A Eckert; Lois J Matthews; Rodney J Schlosser
Journal:  Am J Rhinol Allergy       Date:  2018-04-17       Impact factor: 2.467

5.  Ultrasonographic optic nerve sheath diameter monitoring of elevated intracranial pressure: two case reports.

Authors:  Li-Juan Wang; Hong-Xiu Chen; Lan Tong; Li-Min Chen; Ya-Nan Dong; Ying-Qi Xing
Journal:  Ann Transl Med       Date:  2020-01

6.  Automatic Estimation of the Optic Nerve Sheath Diameter from Ultrasound Images.

Authors:  Samuel Gerber; Maeliss Jallais; Hastings Greer; Matt McCormick; Sean Montgomery; Bradley Freeman; Deborah Kane; Deepak Chittajallu; Neal Siekierski; Stephen Aylward
Journal:  Imaging Patient Cust Simul Syst Point Care Ultrasound (2017)       Date:  2018-09-08

Review 7.  An insight into the vision impairment following traumatic brain injury.

Authors:  Nilkantha Sen
Journal:  Neurochem Int       Date:  2017-02-02       Impact factor: 3.921

8.  The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - Part I: Correlations, age-dependency and cut-off values.

Authors:  Susanne R Kerscher; Daniel Schöni; Helene Hurth; Felix Neunhoeffer; Karin Haas-Lude; Markus Wolff; Martin U Schuhmann
Journal:  Childs Nerv Syst       Date:  2019-06-29       Impact factor: 1.475

9.  Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure.

Authors:  Li-Juan Wang; Li-Min Chen; Ying Chen; Li-Yang Bao; Nan-Nan Zheng; Yu-Zhi Wang; Ying-Qi Xing
Journal:  JAMA Ophthalmol       Date:  2018-03-01       Impact factor: 7.389

10.  Optic nerve sheath diameter does not correlate with intracranial pressure in pediatric neurocritical care patients.

Authors:  Austin Biggs; Marlina Lovett; Melissa Moore-Clingenpeel; Nicole O'Brien
Journal:  Childs Nerv Syst       Date:  2020-10-03       Impact factor: 1.475

View more