Literature DB >> 32055611

Ultrasonographic optic nerve sheath diameter monitoring of elevated intracranial pressure: two case reports.

Li-Juan Wang1, Hong-Xiu Chen1, Lan Tong2, Li-Min Chen1, Ya-Nan Dong1, Ying-Qi Xing1.   

Abstract

Ultrasonography assessments of optic nerve sheath diameter (ONSD) is a non-invasive method that may help identify elevated intracranial pressure (ICP). However, this technique was used to evaluate the elevated ICP caused by traumatic brain injury. The objective of this study was to examine clinical cases of the changes in ICP with venous sinus stenosis and venous sinus thrombosis found the advantage of this technique in the application. And we dynamically monitor ONSD and ICP as a lens for understanding the dynamic assessment for ICP. The first case of venous sinus stenosis with elevated ICP identified in real-time by changes in ONSD, which are correlated with ICP before and after stenting. Another case of venous sinus thrombosis with elevated ICP. And after treatment, the patient underwent an ultrasound ONSD examination and lumbar puncture (LP) at the 1st, the 2nd and 3rd month of follow-up. The previously enlarged ONSDs retracted and LP opening pressure gradually returned to normal. These cases indicate that ONSD examination may help dynamically assess ICP changes and evaluate the efficacy of ICP treatment. These results provide utile, evidence based, preliminary clinical recommendations and indicate that ONSD examination might be a useful method of evaluating ICP, especially if repeated evaluations are needed. 2020 Annals of Translational Medicine. All rights reserved.

Entities:  

Keywords:  Intracranial pressure (ICP); cerebral venous sinus stenosis; optic nerve sheath diameter (ONSD); ultrasound; venous sinus thrombosis

Year:  2020        PMID: 32055611      PMCID: PMC6995732          DOI: 10.21037/atm.2019.12.16

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


  31 in total

1.  Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure - an experimental ultrasound study.

Authors:  Hans-Christian Hansen; Wolf Lagrèze; Oswald Krueger; Knut Helmke
Journal:  Acta Ophthalmol       Date:  2011-04-21       Impact factor: 3.761

2.  Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure.

Authors:  Robert Major; Simon Girling; Adrian Boyle
Journal:  Emerg Med J       Date:  2010-08-15       Impact factor: 2.740

3.  Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests.

Authors:  H C Hansen; K Helmke
Journal:  J Neurosurg       Date:  1997-07       Impact factor: 5.115

Review 4.  Optic nerve sonography: a new window for the non-invasive evaluation of intracranial pressure in brain injury.

Authors:  T Soldatos; K Chatzimichail; M Papathanasiou; A Gouliamos
Journal:  Emerg Med J       Date:  2009-09       Impact factor: 2.740

Review 5.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

6.  Real time optic nerve sheath diameter measurement during lumbar puncture.

Authors:  Getaw Worku Hassen; Mohammed Al-Juboori; Barbara Koppel; Gokhan Akfirat; Hossein Kalantari
Journal:  Am J Emerg Med       Date:  2018-01-10       Impact factor: 2.469

7.  Real-time optic nerve sheath diameter reduction measured with bedside ultrasound after therapeutic lumbar puncture in a patient with idiopathic intracranial hypertension.

Authors:  Jennifer Singleton; Alon Dagan; Jonathan A Edlow; Beatrice Hoffmann
Journal:  Am J Emerg Med       Date:  2014-12-19       Impact factor: 2.469

8.  Architecture of arachnoid trabeculae, pillars, and septa in the subarachnoid space of the human optic nerve: anatomy and clinical considerations.

Authors:  H E Killer; H R Laeng; J Flammer; P Groscurth
Journal:  Br J Ophthalmol       Date:  2003-06       Impact factor: 4.638

9.  Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury.

Authors:  Thomas Geeraerts; Yoann Launey; Laurent Martin; Julien Pottecher; Bernard Vigué; Jacques Duranteau; Dan Benhamou
Journal:  Intensive Care Med       Date:  2007-08-01       Impact factor: 17.440

10.  Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter.

Authors:  Li-Juan Wang; Yan Yao; Liang-Shu Feng; Yu-Zhi Wang; Nan-Nan Zheng; Jia-Chun Feng; Ying-Qi Xing
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

View more
  2 in total

1.  Optic nerve sheath diameter and its implications in the evaluation of cerebral venous sinus thrombosis.

Authors:  Sudha Kiran Das; Saurabh Jindal; Vikram Patil; T Sachin
Journal:  Pol J Radiol       Date:  2022-04-01

2.  Brain-Relaxing Effect of Different Diuretic Regimens in Supratentorial Tumor Surgery: A Comparative Study Guided by Optic Nerve Sheath Diameter.

Authors:  Mohamed Adel Aboelela; Alrefaey Kandeel Alrefaey
Journal:  Anesth Essays Res       Date:  2021-03-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.