Literature DB >> 25954415

Reducing wrong patient selection errors: exploring the design space of user interface techniques.

Awalin Sopan1, Catherine Plaisant2, Seth Powsner3, Ben Shneiderman1.   

Abstract

Wrong patient selection errors are a major issue for patient safety; from ordering medication to performing surgery, the stakes are high. Widespread adoption of Electronic Health Record (EHR) and Computerized Provider Order Entry (CPOE) systems makes patient selection using a computer screen a frequent task for clinicians. Careful design of the user interface can help mitigate the problem by helping providers recall their patients' identities, accurately select their names, and spot errors before orders are submitted. We propose a catalog of twenty seven distinct user interface techniques, organized according to a task analysis. An associated video demonstrates eighteen of those techniques. EHR designers who consider a wider range of human-computer interaction techniques could reduce selection errors, but verification of efficacy is still needed.

Entities:  

Mesh:

Year:  2014        PMID: 25954415      PMCID: PMC4420010     

Source DB:  PubMed          Journal:  AMIA Annu Symp Proc        ISSN: 1559-4076


  18 in total

1.  The use of patient pictures and verification screens to reduce computerized provider order entry errors.

Authors:  Daniel Hyman; Mariel Laire; Diane Redmond; David W Kaplan
Journal:  Pediatrics       Date:  2012-06-04       Impact factor: 7.124

2.  Oops, Sorry, Wrong Patient!: Applying the Joint Commission's "Two-Identifier" Rule Goes beyond the Patient's Room.

Authors:  Matthew Grissinger
Journal:  P T       Date:  2008-11

3.  Minimizing electronic health record patient-note mismatches.

Authors:  Adam B Wilcox; Yueh-Hsia Chen; George Hripcsak
Journal:  J Am Med Inform Assoc       Date:  2011-04-12       Impact factor: 4.497

4.  Matching identifiers in electronic health records: implications for duplicate records and patient safety.

Authors:  Allison B McCoy; Adam Wright; Michael G Kahn; Jason S Shapiro; Elmer Victor Bernstam; Dean F Sittig
Journal:  BMJ Qual Saf       Date:  2013-01-29       Impact factor: 7.035

5.  Visualizing thought.

Authors:  Barbara Tversky
Journal:  Top Cogn Sci       Date:  2010-08-19

6.  Listen carefully: the risk of error in spoken medication orders.

Authors:  Bruce L Lambert; Laura Walsh Dickey; William M Fisher; Robert D Gibbons; Swu-Jane Lin; Paul A Luce; Conor T McLennan; John W Senders; Clement T Yu
Journal:  Soc Sci Med       Date:  2010-02-17       Impact factor: 4.634

7.  Understanding and preventing wrong-patient electronic orders: a randomized controlled trial.

Authors:  Jason S Adelman; Gary E Kalkut; Clyde B Schechter; Jeffrey M Weiss; Matthew A Berger; Stan H Reissman; Hillel W Cohen; Stephen J Lorenzen; Daniel A Burack; William N Southern
Journal:  J Am Med Inform Assoc       Date:  2012-06-29       Impact factor: 4.497

8.  Role of computerized physician order entry systems in facilitating medication errors.

Authors:  Ross Koppel; Joshua P Metlay; Abigail Cohen; Brian Abaluck; A Russell Localio; Stephen E Kimmel; Brian L Strom
Journal:  JAMA       Date:  2005-03-09       Impact factor: 56.272

9.  Providers do not verify patient identity during computer order entry.

Authors:  Philip L Henneman; Donald L Fisher; Elizabeth A Henneman; Tuan A Pham; Yi Y Mei; Rakesh Talati; Brian H Nathanson; Joan Roche
Journal:  Acad Emerg Med       Date:  2008-07       Impact factor: 3.451

10.  Comparison of alphabetical versus categorical display format for medication order entry in a simulated touch screen anesthesia information management system: an experiment in clinician-computer interaction in anesthesia.

Authors:  Anil A Marian; Franklin Dexter; Peter Tucker; Michael M Todd
Journal:  BMC Med Inform Decis Mak       Date:  2012-05-29       Impact factor: 2.796

View more
  8 in total

1.  Selected Medication Safety Risks That Can Easily Fall Off the Radar Screen.

Authors:  Matthew Grissinger
Journal:  P T       Date:  2018-09

2.  Selected Medication Safety Risks to Manage in 2016-Part I Intravenous Fat Emulsion Needs a Filter.

Authors:  Michael R Cohen; Judy L Smetzer
Journal:  Hosp Pharm       Date:  2016-05

3.  The Impact of a Location-Sensing Electronic Health Record on Clinician Efficiency and Accuracy: A Pilot Simulation Study.

Authors:  Kevin King; John Quarles; Vaishnavi Ravi; Tanvir Irfan Chowdhury; Donia Friday; Craig Sisson; Yusheng Feng
Journal:  Appl Clin Inform       Date:  2018-11-21       Impact factor: 2.342

4.  Characterizing Multitasking and Workflow Fragmentation in Electronic Health Records among Emergency Department Clinicians: Using Time-Motion Data to Understand Documentation Burden.

Authors:  Amanda J Moy; Lucy Aaron; Kenrick D Cato; Jessica M Schwartz; Jonathan Elias; Richard Trepp; Sarah Collins Rossetti
Journal:  Appl Clin Inform       Date:  2021-10-27       Impact factor: 2.762

5.  Limiting the number of open charts does not impact wrong patient order entry in the emergency department.

Authors:  Christina Canfield; Chiedozie Udeh; Heather Blonsky; Aaron C Hamilton; Baruch S Fertel
Journal:  J Am Coll Emerg Physicians Open       Date:  2020-06-18

6.  Association between limiting the number of open records in a tele-critical care setting and retract-reorder errors.

Authors:  Chiedozie Udeh; Christina Canfield; Isaac Briskin; Aaron C Hamilton
Journal:  J Am Med Inform Assoc       Date:  2021-07-30       Impact factor: 7.942

7.  Usability Evaluation of Visual Representation Formats for Emergency Department Records.

Authors:  Nathaniel Brown; Aboozar Eghdam; Sabine Koch
Journal:  Appl Clin Inform       Date:  2019-06-26       Impact factor: 2.342

8.  Automated detection of wrong-drug prescribing errors.

Authors:  Bruce L Lambert; William Galanter; King Lup Liu; Suzanne Falck; Gordon Schiff; Christine Rash-Foanio; Kelly Schmidt; Neeha Shrestha; Allen J Vaida; Michael J Gaunt
Journal:  BMJ Qual Saf       Date:  2019-08-07       Impact factor: 7.035