Literature DB >> 25952020

Reliable femoral frame construction based on MRI dedicated to muscles position follow-up.

G Dubois1, D Bonneau2, V Lafage3, P Rouch2, W Skalli2.   

Abstract

In vivo follow-up of muscle shape variation represents a challenge when evaluating muscle development due to disease or treatment. Recent developments in muscles reconstruction techniques indicate MRI as a clinical tool for the follow-up of the thigh muscles. The comparison of 3D muscles shape from two different sequences is not easy because there is no common frame. This study proposes an innovative method for the reconstruction of a reliable femoral frame based on the femoral head and both condyles centers. In order to robustify the definition of condylar spheres, an original method was developed to combine the estimation of diameters of both condyles from the lateral antero-posterior distance and the estimation of the spheres center from an optimization process. The influence of spacing between MR slices and of origin positions was studied. For all axes, the proposed method presented an angular error lower than 1° with spacing between slice of 10 mm and the optimal position of the origin was identified at 56 % of the distance between the femoral head center and the barycenter of both condyles. The high reliability of this method provides a robust frame for clinical follow-up based on MRI .

Keywords:  Femoral frame; MRI; Muscle; Thigh

Mesh:

Year:  2015        PMID: 25952020     DOI: 10.1007/s11517-015-1302-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  24 in total

1.  Femoral anatomical frame: assessment of various definitions.

Authors:  U Della Croce; V Camomilla; A Leardini; A Cappozzo
Journal:  Med Eng Phys       Date:  2003-06       Impact factor: 2.242

2.  Muscle geometry affects accuracy of forearm volume determination by magnetic resonance imaging (MRI).

Authors:  Carolyn M Eng; Geoff D Abrams; Laura R Smallwood; Richard L Lieber; Samuel R Ward
Journal:  J Biomech       Date:  2007-05-22       Impact factor: 2.712

3.  3D segmentation and quantification of a masticatory muscle from MR data using patient-specific models and matching distributions.

Authors:  H P Ng; S H Ong; J Liu; S Huang; K W C Foong; P S Goh; W L Nowinski
Journal:  J Digit Imaging       Date:  2008-05-31       Impact factor: 4.056

4.  Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays.

Authors:  Y Chaibi; T Cresson; B Aubert; J Hausselle; P Neyret; O Hauger; J A de Guise; W Skalli
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-05-24       Impact factor: 1.763

5.  Which method of hip joint centre localisation should be used in gait analysis?

Authors:  Morgan Sangeux; Hélène Pillet; Wafa Skalli
Journal:  Gait Posture       Date:  2014-02-23       Impact factor: 2.840

6.  Arm and leg composition determined by computed tomography in young and elderly men.

Authors:  C L Rice; D A Cunningham; D H Paterson; M S Lefcoe
Journal:  Clin Physiol       Date:  1989-06

Review 7.  Model analysis of factors influencing the prediction of muscle forces at the knee.

Authors:  R P Mikosz; T P Andriacchi; G B Andersson
Journal:  J Orthop Res       Date:  1988       Impact factor: 3.494

8.  Nonuniform changes in MRI measurements of the thigh muscles after two hamstring strengthening exercises.

Authors:  Jurdan Mendiguchia; Mirian A Garrues; John B Cronin; Bret Contreras; Asier Los Arcos; Nikos Malliaropoulos; Nicola Maffulli; Fernando Idoate
Journal:  J Strength Cond Res       Date:  2013-03       Impact factor: 3.775

9.  Muscle quality. II. Effects Of strength training in 65- to 75-yr-old men and women.

Authors:  B L Tracy; F M Ivey; D Hurlbut; G F Martel; J T Lemmer; E L Siegel; E J Metter; J L Fozard; J L Fleg; B F Hurley
Journal:  J Appl Physiol (1985)       Date:  1999-01

10.  The validity of estimating quadriceps volume from single MRI cross-sections in young men.

Authors:  Christopher I Morse; Hans Degens; David A Jones
Journal:  Eur J Appl Physiol       Date:  2007-03-07       Impact factor: 3.346

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.