Literature DB >> 17521657

Muscle geometry affects accuracy of forearm volume determination by magnetic resonance imaging (MRI).

Carolyn M Eng1, Geoff D Abrams, Laura R Smallwood, Richard L Lieber, Samuel R Ward.   

Abstract

Upper extremity musculoskeletal modeling is becoming increasingly sophisticated, creating a growing need for subject-specific muscle size parameters. One method for determining subject-specific muscle volume is magnetic resonance imaging (MRI). The purpose of this study was to determine the validity of MRI-derived muscle volumes in the human forearm across a variety of muscle sizes and shapes. Seventeen cadaveric forearms were scanned using a fast-spoiled gradient echo pulse sequence with high isotropic spatial resolution (1mm(3) voxels) on a 3T MR system. Pronator teres (PT), extensor carpi radialis brevis (ECRB), extensor pollicis longus (EPL), flexor carpi ulnaris (FCU), and brachioradialis (BR) muscles were manually segmented allowing volume to be calculated. Forearms were then dissected, muscles isolated, and muscle masses obtained, which allowed computation of muscle volume. Intraclass correlation coefficients (ICC(2,1)) and absolute volume differences were used to compare measurement methods. There was excellent agreement between the anatomical and MRI-derived muscle volumes (ICC = 0.97, relative error = 12.8%) when all 43 muscles were considered together. When individual muscles were considered, there was excellent agreement between measurement methods for PT (ICC = 0.97, relative error = 8.4%), ECRB (ICC = 0.93, relative error = 7.7%), and FCU (ICC = 0.91, relative error = 9.8%), and fair agreement for EPL (ICC = 0.68, relative error = 21.6%) and BR (ICC = 0.93, relative error = 17.2%). Thus, while MRI-based measurements of muscle volume produce relatively small errors in some muscles, muscles with high surface area-to-volume ratios may predispose them to segmentation error, and, therefore, the accuracy of these measurements may be unacceptable.

Entities:  

Mesh:

Year:  2007        PMID: 17521657      PMCID: PMC2083633          DOI: 10.1016/j.jbiomech.2007.04.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

1.  Muscle volume, MRI relaxation times (T2), and body composition after spaceflight.

Authors:  A LeBlanc; C Lin; L Shackelford; V Sinitsyn; H Evans; O Belichenko; B Schenkman; I Kozlovskaya; V Oganov; A Bakulin; T Hedrick; D Feeback
Journal:  J Appl Physiol (1985)       Date:  2000-12

2.  Muscle volume is a major determinant of joint torque in humans.

Authors:  T Fukunaga; M Miyatani; M Tachi; M Kouzaki; Y Kawakami; H Kanehisa
Journal:  Acta Physiol Scand       Date:  2001-08

3.  Mechanical considerations in the design of surgical reconstructive procedures.

Authors:  Jan Fridén; Richard L Lieber
Journal:  J Biomech       Date:  2002-08       Impact factor: 2.712

4.  Thigh composition in young and elderly men determined by computed tomography.

Authors:  T J Overend; D A Cunningham; D H Paterson; M S Lefcoe
Journal:  Clin Physiol       Date:  1992-11

5.  Magnetic resonance imaging in quantitative analysis of rotator cuff muscle volume.

Authors:  Markus J Tingart; Maria Apreleva; Janne T Lehtinen; Brian Capell; William E Palmer; Jon J P Warner
Journal:  Clin Orthop Relat Res       Date:  2003-10       Impact factor: 4.176

6.  Density and hydration of fresh and fixed human skeletal muscle.

Authors:  Samuel R Ward; Richard L Lieber
Journal:  J Biomech       Date:  2004-12-30       Impact factor: 2.712

7.  A model of the upper extremity for simulating musculoskeletal surgery and analyzing neuromuscular control.

Authors:  Katherine R S Holzbaur; Wendy M Murray; Scott L Delp
Journal:  Ann Biomed Eng       Date:  2005-06       Impact factor: 3.934

8.  Knee extensor strength, activation, and size in very elderly people following strength training.

Authors:  S D Harridge; A Kryger; A Stensgaard
Journal:  Muscle Nerve       Date:  1999-07       Impact factor: 3.217

9.  Tendon transfers in hand surgery.

Authors:  D C Riordan
Journal:  J Hand Surg Am       Date:  1983-09       Impact factor: 2.230

10.  A more efficient magnetic resonance imaging-based strategy for measuring quadriceps muscle volume.

Authors:  Brian L Tracy; Fred M Ivey; E Jeffrey Metter; Jerome L Fleg; Eliot L Siegel; Ben F Hurley
Journal:  Med Sci Sports Exerc       Date:  2003-03       Impact factor: 5.411

View more
  9 in total

1.  Reliable femoral frame construction based on MRI dedicated to muscles position follow-up.

Authors:  G Dubois; D Bonneau; V Lafage; P Rouch; W Skalli
Journal:  Med Biol Eng Comput       Date:  2015-05-08       Impact factor: 2.602

2.  Paretic muscle atrophy and non-contractile tissue content in individual muscles of the post-stroke lower extremity.

Authors:  John W Ramsay; Peter J Barrance; Thomas S Buchanan; Jill S Higginson
Journal:  J Biomech       Date:  2011-09-25       Impact factor: 2.712

3.  Muscle volume as a predictor of maximum force generating ability in the plantar flexors post-stroke.

Authors:  Brian A Knarr; John W Ramsay; Thomas S Buchanan; Jill S Higginson; Stuart A Binder-Macleod
Journal:  Muscle Nerve       Date:  2013-09-11       Impact factor: 3.217

4.  3D-patient-specific geometry of the muscles involved in knee motion from selected MRI images.

Authors:  I Südhoff; J A de Guise; A Nordez; E Jolivet; D Bonneau; V Khoury; W Skalli
Journal:  Med Biol Eng Comput       Date:  2009-03-10       Impact factor: 2.602

5.  In vivo MRI quantification of individual muscle and organ volumes for assessment of anabolic steroid growth effects.

Authors:  Ed X Wu; Haiying Tang; Christopher Tong; Steve B Heymsfield; Joseph R Vasselli
Journal:  Steroids       Date:  2007-12-23       Impact factor: 2.668

6.  In vivo MRI evaluation of anabolic steroid precursor growth effects in a guinea pig model.

Authors:  Haiying Tang; Joseph R Vasselli; Christopher Tong; Steven B Heymsfield; Ed X Wu
Journal:  Steroids       Date:  2009-03-20       Impact factor: 2.668

7.  Quantifying skeletal muscle volume and shape in humans using MRI: A systematic review of validity and reliability.

Authors:  Christelle Pons; Bhushan Borotikar; Marc Garetier; Valérie Burdin; Douraied Ben Salem; Mathieu Lempereur; Sylvain Brochard
Journal:  PLoS One       Date:  2018-11-29       Impact factor: 3.240

8.  An anatomical classification of congenital proximal radioulnar synostosis based on retrospective MRI measurement combined with radiography.

Authors:  Jin Li; Kailei Chen; Jing Wang; Yueming Guo; Saroj Rai; Xin Tang
Journal:  Sci Rep       Date:  2022-04-21       Impact factor: 4.996

9.  Validity of ultrasonography-derived predictions for estimating skeletal muscle volume: a systematic literature review.

Authors:  Rasmus Liegnell; Fredrik Wessman; Adel Shalabi; Marita Harringe
Journal:  BMC Med Imaging       Date:  2021-07-05       Impact factor: 1.930

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.