Literature DB >> 25944276

[Teleradiological report turnaround times: An internal efficiency and quality control analysis].

T Seithe, M de Bucourt1, T Seithe, R Busse, M Rief, R Doyscher, L Albrecht, H Rathke, M Jonczyk, R Poschmann, H Tepe, B Hamm.   

Abstract

AIMS: The teleradiological examinations performed at the Charité were analyzed for the purpose of internal quality and efficiency control. Data included the type and number of examinations performed, the time of day and week the examination was performed and the differences in teleradiologist report turnaround times.
MATERIAL AND METHODS: A retrospective analysis of the radiology information system (RIS) database of all teleradiological computed tomography examinations performed at the Charité from 2011 through 2013 was carried out. The search retrieved 10,200 teleradiological examinations which were included in the analysis. The records were analyzed for the time of the day and week the examination was performed, the interval between examination and time of reporting, the type of teleradiological examination and the campus in which they were performed.
RESULTS: The number of teleradiological examinations performed increased continuously during the observation period. Computed tomography of the head was the most frequently performed type of examination with 86%. Taking all forms of examination into consideration it took an average of 34 min until a report was written. Over the 3-year observation period the times remained virtually unaltered.
CONCLUSION: During the 3-year observation period nearly constant report times could be observed in spite of the increased numbers of examinations. This indicates an efficiency enhancement and rational integration of teleradiology into the radiological workflow.

Mesh:

Year:  2015        PMID: 25944276     DOI: 10.1007/s00117-015-2858-0

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  31 in total

Review 1.  Quality initiatives: lean approach to improving performance and efficiency in a radiology department.

Authors:  Jonathan B Kruskal; Allen Reedy; Laurie Pascal; Max P Rosen; Phillip M Boiselle
Journal:  Radiographics       Date:  2012-02-08       Impact factor: 5.333

2.  Radiologist report turnaround time: impact of pay-for-performance measures.

Authors:  Giles W L Boland; Elkan F Halpern; G Scott Gazelle
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

3.  Voice recognition software: effect on radiology report turnaround time at an academic medical center.

Authors:  Arun Krishnaraj; Joseph K T Lee; Sandra A Laws; T Jay Crawford
Journal:  AJR Am J Roentgenol       Date:  2010-07       Impact factor: 3.959

4.  Impact of PACS on dictation turnaround time and productivity.

Authors:  Luigi Lepanto; Guy Paré; David Aubry; Pierre Robillard; Jacques Lesage
Journal:  J Digit Imaging       Date:  2006-03       Impact factor: 4.056

5.  The state of teleradiology in 2003 and changes since 1999.

Authors:  Todd L Ebbert; Cristian Meghea; Santiago Iturbe; Howard P Forman; Mythreyi Bhargavan; Jonathan H Sunshine
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

6.  Impact of PACS deployment strategy on dictation turnaround time of chest radiographs.

Authors:  Luigi Lepanto; Guy Paré; Alain Gauvin
Journal:  Acad Radiol       Date:  2006-04       Impact factor: 3.173

7.  The impact of teleradiology in the United States over the last decade: driving consolidation and commoditization of radiologists and radiology services.

Authors:  G W L Boland
Journal:  Clin Radiol       Date:  2009-02-15       Impact factor: 2.350

8.  [Turnaround time for reporting results of radiological examinations in intensive care unit patients: an internal quality control].

Authors:  L Albrecht; R Busse; H Tepe; R Poschmann; U Teichgräber; B Hamm; M de Bucourt
Journal:  Radiologe       Date:  2013-09       Impact factor: 0.635

9.  The value teleradiology represents for Europe: a study of lessons learned in the U.S.

Authors:  Tiron C M Pechet; Greg Girard; Brent Walsh
Journal:  Eur J Radiol       Date:  2009-12-23       Impact factor: 3.528

10.  [Innovative teleradiology network: concept and experience report].

Authors:  M Kämmerer; O T Bethge; G Antoch
Journal:  Radiologe       Date:  2014-04       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.