Trabecular bone strength is not an independent predictive factor for dynamic hip screw migration--A prospective multicenter cohort study.

Marc A Müller1, Clemens Hengg2, Christian Krettek3, Detlef van der Velde4, Siegfried Eberdorfer5, Richard Stange6, Gunther O Hofmann7, Andreas Platz8, Norbert Suhm1.   

Abstract

This study assessed whether mechanically measured trabecular bone strength is an independent predictor of dynamic hip screw (DHS) stability, i.e., DHS migration (DHSM) after the fixation of proximal femoral fractures. One-hundred and seven patients older than 50 years with proximal femoral fractures were included. During fracture fixation, a mechanical probe (DensiProbe™ Hip) was inserted at the site where the DHS tip would ultimately be positioned. Peak torque to breakaway the trabecular bone was measured. Fracture reduction, primary implant position and postoperative DHSM were assessed by radiographs taken postoperatively, at 6 and 12 weeks after surgery. Univariate regression analysis revealed no association between peak torque and DHSM (R(2) = 0.025, p = 0.135). DHSM correlated with the primary DHS position, i.e., the distance between the DHS and (i) the central femoral neck axis (CNFAD, R(2) = 0.230; p < 0.0001) and (ii) the apex of the femoral head (R(2) = 0.110; p = 0.001). DHSM did not correlate with areal BMD of the contralateral proximal femur. Multivariable regression modeling revealed the CFNAD as predictive factor for screw migration. The primary implant position measured by the CFNAD, rather than DensiProbe™ Hip measured bone strength, is an independent predictor of DHSM.
© 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  bone strength; dynamic hip screw migration; implant stability

Mesh:

Year:  2015        PMID: 25929756     DOI: 10.1002/jor.22934

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Trochanteric fragility fractures : Treatment using the cement-augmented proximal femoral nail antirotation.

Authors:  C Neuerburg; S Mehaffey; M Gosch; W Böcker; M Blauth; C Kammerlander
Journal:  Oper Orthop Traumatol       Date:  2016-05-31       Impact factor: 1.154

2.  A novel method for intraoperative osseomechanical strength measurements: a biomechanical ex vivo evaluation on proximal femora.

Authors:  Alexander Maslaris; Olaf Brinkmann; Frank Layher; Georg Matziolis; Matthias Bungartz
Journal:  Arch Orthop Trauma Surg       Date:  2019-11-06       Impact factor: 3.067

3.  Feasibility Analysis of a Novel Method for the Estimation of Local Bone Mechanical Properties: A Preliminary Investigation of Different Pressure Rod Designs on Synthetic Cancellous Bone Models.

Authors:  Alexander Maslaris; Matthias Bungartz; Frank Layher; Timo Zippelius; Georg Matziolis; Olaf Brinkmann
Journal:  Arch Bone Jt Surg       Date:  2021-03

4.  Incredible position of broken sliding dynamic hip screw implant in the medial of thigh.

Authors:  Saeed Solooki; Amir Reza Vosoughi
Journal:  Acta Orthop Traumatol Turc       Date:  2017-04-25       Impact factor: 1.511

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.