The influence of cochlear implant electrode position on performance.

Kim S van der Marel1, Jeroen J Briaire, Berit M Verbist, Tjeerd J Muurling, Johan H M Frijns.   

Abstract

OBJECTIVES: To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population.
DESIGN: The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics. Phoneme and word score averages for the 1- and 2-year follow-up were calculated for 41 prelingually deaf and 162 postlingually deaf patients. Analyses to reveal correlations between these performance outcomes and 6 position-related variables (angle of most basal electrode contact, surgical insertion angle, surgical insertion, wrapping factor, angular insertion depth, linear insertion depth) were executed. The scalar location, as an indication for the presence of intracochlear trauma, and modiolus proximity beyond the basal turn were not evaluated in this study. In addition, different patient-specific variables (age at implantation, age at onset of hearing loss, duration of deafness, preoperative phoneme and word scores) were tested for correlation with performance.
RESULTS: The performance scores of prelingual patients were correlated with age at onset of hearing loss, duration of deafness and preoperative scores. For the postlingual patients, performance showed correlations with all 5 patient-specific variables. None of the 6 position-related variables influenced speech perception in cochlear implant patients.
CONCLUSIONS: Although several patient-specific variables showed correlations with speech perception outcomes, not one of the studied angular and linear position-related variables turned out to have a demonstrable influence on performance.

Entities:  

Mesh:

Year:  2015        PMID: 25924706     DOI: 10.1159/000377616

Source DB:  PubMed          Journal:  Audiol Neurootol        ISSN: 1420-3030            Impact factor:   1.854


  21 in total

1.  Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners.

Authors:  Lindsay DeVries; Julie G Arenberg
Journal:  J Assoc Res Otolaryngol       Date:  2018-06-04

2.  Late Cochlear Implantation in Early-Deafened Adults: A Detailed Analysis of Auditory and Self-Perceived Benefits.

Authors:  Joke Debruyne; Miranda Janssen; Jan Brokx
Journal:  Audiol Neurootol       Date:  2018-06-28       Impact factor: 1.854

3.  Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds.

Authors:  Lindsay DeVries; Rachel Scheperle; Julie Arenberg Bierer
Journal:  J Assoc Res Otolaryngol       Date:  2016-02-29

4.  Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant Users.

Authors:  Quentin Mesnildrey; Frédéric Venail; Robert P Carlyon; Olivier Macherey
Journal:  J Assoc Res Otolaryngol       Date:  2020-02-04

5.  Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes.

Authors:  Brendan P O'Connell; Jacob B Hunter; David S Haynes; Jourdan T Holder; Matt M Dedmon; Jack H Noble; Benoit M Dawant; George B Wanna
Journal:  Laryngoscope       Date:  2017-03-17       Impact factor: 3.325

6.  Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation.

Authors:  Brendan P O'Connell; Ahmet Cakir; Jacob B Hunter; David O Francis; Jack H Noble; Robert F Labadie; Geraldine Zuniga; Benoit M Dawant; Alejandro Rivas; George B Wanna
Journal:  Otol Neurotol       Date:  2016-09       Impact factor: 2.311

Review 7.  Electric and Acoustic Stimulation in Cochlear Implant Recipients with Hearing Preservation.

Authors:  Christopher Welch; Margaret T Dillon; Harold C Pillsbury
Journal:  Semin Hear       Date:  2018-10-26

8.  The effect of increased channel interaction on speech perception with cochlear implants.

Authors:  Tobias Goehring; Alan W Archer-Boyd; Julie G Arenberg; Robert P Carlyon
Journal:  Sci Rep       Date:  2021-05-17       Impact factor: 4.379

9.  Factors Influencing Speech Perception in Adults With a Cochlear Implant.

Authors:  Floris Heutink; Berit M Verbist; Willem-Jan van der Woude; Tamara J Meulman; Jeroen J Briaire; Johan H M Frijns; Priya Vart; Emmanuel A M Mylanus; Wendy J Huinck
Journal:  Ear Hear       Date:  2021 July/Aug       Impact factor: 3.562

10.  Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis.

Authors:  Andreas Büchner; Angelika Illg; Omid Majdani; Thomas Lenarz
Journal:  PLoS One       Date:  2017-05-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.