Literature DB >> 25911425

Identification in residue analysis based on liquid chromatography with tandem mass spectrometry: Experimental evidence to update performance criteria.

Hans G J Mol1, Paul Zomer2, Mónica García López3, Richard J Fussell3, Jos Scholten4, Andre de Kok4, Anne Wolheim5, Michelangelo Anastassiades5, Ana Lozano6, Amadeo Fernandez Alba6.   

Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is one of the most widely used techniques for identification (and quantification) of residues and contaminants across a number of different chemical domains. Although the same analytical technique is used, the parameters and criteria for identification vary depending on where in the world the analysis is performed and for what purpose (e.g. determination of pesticides, veterinary drugs, forensic toxicology, sports doping). The rationale for these differences is not clear and in most cases the criteria are essentially based on expert opinions rather than underpinned by experimental data. In the current study, the variability of the two key identification parameters, retention time and ion ratio, was assessed and compared against requirements set out in different legal and guidance documents. The study involved the analysis of 120 pesticides, representing various chemical classes, polarities, molecular weights, and detector response factors, in 21 different fruit and vegetable matrices of varying degrees of complexity. The samples were analysed non-fortified, and fortified at 10, 50 and 200 μg kg(-1), in five laboratories using different LC-MS/MS instruments and conditions. In total, over 135,000 extracted-ion chromatograms were manually verified to provide an extensive data set for the assessment. The experimental data do not support relative tolerances for retention time, or different tolerances for ion ratios depending on relative abundance of the two product ions measured. Retention times in today's chromatographic systems are sufficiently stable to justify an absolute tolerance of ±0.1 min. Ion ratios are stable as long as sufficient response is obtained for both product ions. Ion ratio deviations are typically within ±20% (relative), and within ±45% (relative) in case the response of product ions are close to the limit of detection. Ion ratio tolerances up to 50% did not result in false positives and reduced the false negative rate for pesticides with product ions in the low S/N range to <5%. Without ion ratio criterion, two false positives were obtained in 105 non-fortified samples. Although the study has been conducted for pesticides residues in fruits and vegetables, the impact of these findings is believed to extend towards other application areas and possibly support adjustment or consolidation of criteria across other analytical domains.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Food; Identification; Liquid chromatography; Performance criteria; Pesticides; Tandem mass spectrometry

Year:  2015        PMID: 25911425     DOI: 10.1016/j.aca.2015.03.007

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  7 in total

1.  Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data.

Authors:  Bertrand Rochat
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-23       Impact factor: 3.109

2.  Towards the development of innovative multi-mycotoxin reference materials as promising metrological tool for emerging and regulated mycotoxin analyses.

Authors:  E K Tangni; P Debongnie; B Huybrechts; F Van Hove; A Callebaut
Journal:  Mycotoxin Res       Date:  2016-11-04       Impact factor: 3.833

3.  Comparison of allergen quantification strategies for egg, milk, and peanut in food using targeted LC-MS/MS.

Authors:  Weili Xiong; Christine H Parker; Chelsea C Boo; Katherine L Fiedler
Journal:  Anal Bioanal Chem       Date:  2021-08-03       Impact factor: 4.142

4.  Dissipation of S-metolachlor in plant and soil and effect on enzymatic activities.

Authors:  Elżbieta Wołejko; Piotr Kaczyński; Bożena Łozowicka; Urszula Wydro; Andrzej Borusiewicz; Izabela Hrynko; Rafał Konecki; Krystyna Snarska; Dorota Dec; Paweł Malinowski
Journal:  Environ Monit Assess       Date:  2017-06-27       Impact factor: 2.513

5.  Trace analysis of multi-class pesticide residues in Chinese medicinal health wines using gas chromatography with electron capture detection.

Authors:  Wei-Jun Kong; Qiu-Tao Liu; Dan-Dan Kong; Qian-Zhen Liu; Xin-Ping Ma; Mei-Hua Yang
Journal:  Sci Rep       Date:  2016-02-17       Impact factor: 4.379

6.  Establishing Analytical Performance Criteria for the Global Reconnaissance of Antibiotics and Other Pharmaceutical Residues in the Aquatic Environment Using Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Luisa F Angeles; Diana S Aga
Journal:  J Anal Methods Chem       Date:  2018-06-04       Impact factor: 2.193

7.  Organisation of Multi-Mycotoxin Proficiency Tests: Evaluation of the Performances of the Laboratories Using the Triple A Rating Approach.

Authors:  Emmanuel K Tangni; Bart Huybrechts; Julien Masquelier; Els Van Hoeck
Journal:  Toxins (Basel)       Date:  2021-08-24       Impact factor: 4.546

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.