Literature DB >> 25909014

Nodal lymph flow quantified with afferent vessel input function allows differentiation between normal and cancer-bearing nodes.

Alisha V DSouza1, Jonathan T Elliott2, Jason R Gunn2, Richard J Barth3, Kimberley S Samkoe4, Kenneth M Tichauer5, Brian W Pogue6.   

Abstract

Morbidity and complexity involved in lymph node staging via surgical resection and biopsy could ideally be improved using node assay techniques that are non-invasive. While visible blue dyes are often used to locate the sentinel lymph nodes from draining lymphatic vessels near a tumor, they do not provide an in situ metric to evaluate presence of cancer. In this study, the transport kinetics of methylene blue were analyzed to determine the potential for better in situ information about metastatic involvement in the nodes. A rat model with cancer cells in the axillary lymph nodes was used, with methylene blue injection to image the fluorescence kinetics. The lymphatic flow from injection sites to nodes was imaged and the relative kinetics from feeding lymphatic ducts relative to lymph nodes was quantified. Large variability existed in raw fluorescence and transport patterns within each cohort resulting in no systematic difference between average nodal uptake in normal, sham control and cancer-bearing nodes. However, when the signal from the afferent lymph vessel fluorescence was used to normalize the signal of the lymph nodes, the high signal heterogeneity was reduced. Using a model, the lymph flow through the nodes [Formula: see text] was estimated to be 1.49 ± 0.64 ml/g/min in normal nodes, 1.53 ± 0.45 ml/g/min in sham control nodes, and reduced to 0.50 ± 0.24 ml/g/min in cancer-cell injected nodes. This summarizes the significant difference (p = 0.0002) between cancer-free and cancer-bearing nodes in normalized flow. This process of normalized flow imaging could be used as an in situ tool to detect metastatic involvement in nodes.

Entities:  

Keywords:  (170.0170) Medical optics and biotechnology; (170.2655) Functional monitoring and imaging

Year:  2015        PMID: 25909014      PMCID: PMC4399669          DOI: 10.1364/BOE.6.001304

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  32 in total

1.  Impact of neck dissection on quality of life.

Authors:  A L Kuntz; E A Weymuller
Journal:  Laryngoscope       Date:  1999-08       Impact factor: 3.325

Review 2.  Lymphatic mapping and sentinel node analysis: current concepts and applications.

Authors:  Steven L Chen; Douglas M Iddings; Randall P Scheri; Anton J Bilchik
Journal:  CA Cancer J Clin       Date:  2006 Sep-Oct       Impact factor: 508.702

3.  Quantifying cerebral blood flow in an adult pig ischemia model by a depth-resolved dynamic contrast-enhanced optical method.

Authors:  Jonathan T Elliott; Mamadou Diop; Laura B Morrison; Christopher D d'Esterre; Ting-Yim Lee; Keith St Lawrence
Journal:  Neuroimage       Date:  2014-03-17       Impact factor: 6.556

4.  Dynamic CT measurement of cerebral blood flow: a validation study.

Authors:  A Cenic; D G Nabavi; R A Craen; A W Gelb; T Y Lee
Journal:  AJNR Am J Neuroradiol       Date:  1999-01       Impact factor: 3.825

5.  Quantitative near infrared spectroscopy measurement of cerebral hemodynamics in newborn piglets.

Authors:  Derek W Brown; Paul A Picot; Jafar Gharavi Naeini; Roger Springett; David T Delpy; Ting-Yim Lee
Journal:  Pediatr Res       Date:  2002-05       Impact factor: 3.756

6.  A macrophage-specific fluorescent probe for intraoperative lymph node staging.

Authors:  Jung Sun Yoo; Sung-Chan Lee; Zhi Yen Jow; Pamela Yun Xiang Koh; Young-Tae Chang
Journal:  Cancer Res       Date:  2013-12-09       Impact factor: 12.701

7.  Noninvasive quantitative imaging of lymph function in mice.

Authors:  Sunkuk Kwon; Eva M Sevick-Muraca
Journal:  Lymphat Res Biol       Date:  2007       Impact factor: 2.589

8.  The FLARE intraoperative near-infrared fluorescence imaging system: a first-in-human clinical trial in breast cancer sentinel lymph node mapping.

Authors:  Susan L Troyan; Vida Kianzad; Summer L Gibbs-Strauss; Sylvain Gioux; Aya Matsui; Rafiou Oketokoun; Long Ngo; Ali Khamene; Fred Azar; John V Frangioni
Journal:  Ann Surg Oncol       Date:  2009-07-07       Impact factor: 5.344

Review 9.  Near infrared fluorescent optical imaging for nodal staging.

Authors:  Lakshmi Sampath; Wei Wang; Eva M Sevick-Muraca
Journal:  J Biomed Opt       Date:  2008 Jul-Aug       Impact factor: 3.170

10.  Real-time in vivo molecular detection of primary tumors and metastases with ratiometric activatable cell-penetrating peptides.

Authors:  Elamprakash N Savariar; Csilla N Felsen; Nadia Nashi; Tao Jiang; Lesley G Ellies; Paul Steinbach; Roger Y Tsien; Quyen T Nguyen
Journal:  Cancer Res       Date:  2012-11-27       Impact factor: 12.701

View more
  5 in total

Review 1.  Proteolysis and Oxidation of Therapeutic Proteins After Intradermal or Subcutaneous Administration.

Authors:  Ninad Varkhede; Rupesh Bommana; Christian Schöneich; M Laird Forrest
Journal:  J Pharm Sci       Date:  2019-08-10       Impact factor: 3.534

2.  Development and evaluation of a connective tissue phantom model for subsurface visualization of cancers requiring wide local excision.

Authors:  Kimberley S Samkoe; Brent D Bates; Niki N Tselepidakis; Alisha V DSouza; Jason R Gunn; Dipak B Ramkumar; Keith D Paulsen; Brian W Pogue; Eric R Henderson
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

3.  Paired-agent imaging for detection of head and neck cancers.

Authors:  Kimberley S Samkoe; Yeonjae Park; Kayla Marra; Eunice Y Chen; Kenneth M Tichauer
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-02-26

4.  Optical tracer size differences allow quantitation of active pumping rate versus Stokes-Einstein diffusion in lymphatic transport.

Authors:  Alisha V DSouza; Kayla Marra; Jason R Gunn; Kimberley S Samkoe; Brian W Pogue
Journal:  J Biomed Opt       Date:  2016-10-01       Impact factor: 3.170

5.  Paired-Agent Fluorescence Molecular Imaging of Sentinel Lymph Nodes Using Indocyanine Green as a Control Agent for Antibody-Based Targeted Agents.

Authors:  Chengyue Li; Xiaochun Xu; Nathan McMahon; Omar Alhaj Ibrahim; Husain A Sattar; Kenneth M Tichauer
Journal:  Contrast Media Mol Imaging       Date:  2019-01-03       Impact factor: 3.161

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.