Literature DB >> 27752703

Optical tracer size differences allow quantitation of active pumping rate versus Stokes-Einstein diffusion in lymphatic transport.

Alisha V DSouza1, Kayla Marra1, Jason R Gunn1, Kimberley S Samkoe2, Brian W Pogue2.   

Abstract

Lymphatic uptake of interstitially administered agents occurs by passive convective–diffusive inflow driven by interstitial concentration and pressure, while the downstream lymphatic transport is facilitated by active propulsive contractions of lymphatic vessel walls. Near-infrared fluorescence imaging in mice was used to measure these central components of lymphatic transport for the first time, using two different-sized molecules––methylene blue (MB) and fluorescence-labeled antibody immunoglobulin G (IgG)-IRDye 680RD. This work confirms the hypothesis that lymphatic passive inflow and active propulsion rates can be separated based upon the relative differences in Stokes–Einstein diffusion coefficient. This coefficient specifically affects the passive-diffusive uptake when the interstitial volume and pressure are constant. Parameters such as mean time-to-peak signal, overall fluorescence signal intensities, and number of active peristaltic pulses, were estimated from temporal imaging data. While the mean time to attain peak signal representative of diffusion-dominated flow in the lymph vessels was 0.6±0.2??min for MB and 8±6??min for IgG, showing a size dependence, the active propulsion rates were 3.4±0.8??pulses/min and 3.3±0.5??pulses/min, respectively, appearing size independent. The propulsion rates for both dyes decreased with clearance from the interstitial injection-site, indicating intrinsic control of the smooth muscles in response to interstitial pressure. This approach to size-comparative agent flow imaging of lymphatic function can enable noninvasive characterization of diseases related to uptake and flow in lymph networks.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27752703      PMCID: PMC5067306          DOI: 10.1117/1.JBO.21.10.100501

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  22 in total

Review 1.  HEVs, lymphatics and homeostatic immune cell trafficking in lymph nodes.

Authors:  Jean-Philippe Girard; Christine Moussion; Reinhold Förster
Journal:  Nat Rev Immunol       Date:  2012-09-28       Impact factor: 53.106

Review 2.  Lymphatic drug delivery using engineered liposomes and solid lipid nanoparticles.

Authors:  Shuang Cai; Qiuhong Yang; Taryn R Bagby; M Laird Forrest
Journal:  Adv Drug Deliv Rev       Date:  2011-06-25       Impact factor: 15.470

Review 3.  Interstitial fluid and lymph formation and transport: physiological regulation and roles in inflammation and cancer.

Authors:  Helge Wiig; Melody A Swartz
Journal:  Physiol Rev       Date:  2012-07       Impact factor: 37.312

4.  Noninvasive real-time fluorescence imaging of the lymphatic uptake of BSA-IRDye 680 conjugate administered subcutaneously in mice.

Authors:  Fang Wu; Suraj G Bhansali; Mitalee Tamhane; Rajiv Kumar; Lisa A Vathy; Hong Ding; Ken-Tye Yong; Earl J Bergey; Paras N Prasad; Marilyn E Morris
Journal:  J Pharm Sci       Date:  2012-01-19       Impact factor: 3.534

Review 5.  Imaging of the interaction of cancer cells and the lymphatic system.

Authors:  Hop S Tran Cao; Michele McElroy; Sharmeela Kaushal; Robert M Hoffman; Michael Bouvet
Journal:  Adv Drug Deliv Rev       Date:  2011-06-28       Impact factor: 15.470

6.  Method for the quantitative measurement of collecting lymphatic vessel contraction in mice.

Authors:  Shan Liao; Dennis Jones; Gang Cheng; Timothy P Padera
Journal:  J Biol Methods       Date:  2014

7.  Lymphatic metastasis in the absence of functional intratumor lymphatics.

Authors:  Timothy P Padera; Ananth Kadambi; Emmanuelle di Tomaso; Carla Mouta Carreira; Edward B Brown; Yves Boucher; Noah C Choi; Douglas Mathisen; John Wain; Eugene J Mark; Lance L Munn; Rakesh K Jain
Journal:  Science       Date:  2002-04-25       Impact factor: 47.728

8.  Near-Infrared Fluorescence Lymphatic Imaging in Lymphangiomatosis.

Authors:  John C Rasmussen; Caroline E Fife; Eva M Sevick-Muraca
Journal:  Lymphat Res Biol       Date:  2015-08-19       Impact factor: 2.589

9.  Noninvasive quantitative imaging of lymph function in mice.

Authors:  Sunkuk Kwon; Eva M Sevick-Muraca
Journal:  Lymphat Res Biol       Date:  2007       Impact factor: 2.589

10.  Why certain dyes are useful for localizing the sentinel lymph node.

Authors:  Chris Tsopelas; Richard Sutton
Journal:  J Nucl Med       Date:  2002-10       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.