Anna Zykova1, Vladimir Safonov1, Anna Yanovska2, Leonid Sukhodub3, Renata Rogovskaya4, Jerzy Smolik4, Stas Yakovin5.
Abstract
Hydroxyapatite Ca10(PO4)6(OH)2 (HAp) and calcium phosphate ceramic materials and coatings are widely used in medicine and dentistry because of their ability to enhance the tissue response to implant surfaces and promote bone ingrowth and osseoconduction processes. The deposition conditions have a great influence on the structure and biofunctionality of calcium phosphate coatings. Corrosion processes and poor adhesion to substrate material reduce the lifetime of implants with calcium phosphate coatings. The research has focused on the development of advanced methods to deposit double-layered ceramic oxide/calcium phosphate coatings by a hybrid technique of magnetron sputtering and thermal methods. The thermal method can promote the crystallization and the formation of HAp coatings on titanium alloy Ti6Al4V substrates at low temperature, based on the principle that the solubility of HAp in aqueous solutions decreases with increasing substrate temperature. By this method, hydroxyapatite directly coated the substrate without precipitation in the initial solution. Using a thermal substrate method, calcium phosphate coatings were prepared at substrate temperatures of 100-105 (o)C. The coated metallic implant surfaces with ceramic bond coats and calcium phosphate layers combine the excellent mechanical properties of metals with the chemical stability of ceramic materials. The corrosion test results show that the ceramic oxide (alumina) coatings and the double-layered alumina-calcium phosphate coatings improve the corrosion resistance compared with uncoated Ti6Al4V and single-layered Ti6Al4V/calcium phosphate substrates. In addition, the double-layered alumina/hydroxyapatite coatings demonstrate the best biocompatibility during in vitro tests.Entities:
Keywords: Alumina; biocompatibility; hydroxyapatite; magnetron sputtering; potentiodynamic testing; thermal method
Year: 2015 PMID: 25893018 PMCID: PMC4391219 DOI: 10.2174/1874120701509010075
Source DB: PubMed Journal: Open Biomed Eng J ISSN: 1874-1207
Results of EDS elemental analysis of calcium phosphate crystalson a Ti6Al4V substrate at selected points shown in Fig. (5).
|
|
|
|
|
|---|---|---|---|
| 1 | 21.07 | 11.62 | 1.41 |
| 2 | 20.01 | 11.07 | 1.40 |
| 3 | 20.96 | 12.57 | 1.29 |
Results of EDS elemental analysis of HAp crystals on a Ti6Al4V/Al2O3 substrate at selected points shown in Fig.6
|
|
|
|
|
|
|---|---|---|---|---|
| 1 | 1.97 | 68.12 | 29.91 | 1.77 |
| 2 | 2.31 | 66.16 | 31.53 | 1.62 |
| 3 | 2.73 | 65.58 | 31.69 | 1.60 |
| 4 | 2.34 | 66.68 | 30.98 | 1.67 |
Mechanical characteristics of single-layer HAp coatings and double-layered alumina/hydroxyapatite coatings deposited onTi6Al4V substrates.
|
|
|
|
|
|
|---|---|---|---|---|
| Ti6Al4V | 110 | 415 | ||
| Ti6Al4V /Al2O3 | 2.1 | 39.8 | 172 | 953 |
| Ti6Al4V/HAp | 30.3 | 12.7 | 102 | 422 |
| Ti6Al4V /Al2O3 /HAp | 1.9 | 35.2 | 151 | 831 |