Literature DB >> 25869588

Midterm Outcomes of the Recently FDA Approved Ceramic on Ceramic Bearing in Total Hip Arthroplasty Patients Under 65 Years of Age.

Ahmed A Aoude1, John Antoniou2, Laura M Epure2, Olga L Huk2, David J Zukor2, Michael Tanzer1.   

Abstract

The present study aimed to evaluate the mid-term results of the fourth generation of ceramic on ceramic (CC) bearing. Demographics, surgical technique, complications, clinical and radiologic outcomes were analyzed in a series of 133 consecutive CC total hip arthroplasties (THAs) with a newest generation CC bearings to determine if these provide safe and well performing bearings. At the last follow-up, there were no cases of ceramic fracture or chipping and no revision surgery necessary for bearing related complication. One hip underwent two staged revision for infection and another underwent revision for dislocation, resulting in an overall 98.5% survival rate at a mean of 6 years. The newest generation of CC bearings provides a reliable and safe bearing in young, active patients undergoing THA.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  BIOLOX delta; ceramic on ceramic; hip squeaking; implant fracture; total hip arthroplasty

Mesh:

Year:  2015        PMID: 25869588     DOI: 10.1016/j.arth.2015.03.028

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty.

Authors:  Young-Kyun Lee; Jae-Young Lim; Yong-Chan Ha; Tae-Young Kim; Woon-Hwa Jung; Kyung-Hoi Koo
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-12       Impact factor: 3.067

2.  Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.

Authors:  Denis Nam; Toby Barrack; Staci R Johnson; Ryan M Nunley; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

3.  Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up.

Authors:  Alessandro Bistolfi; Riccardo Ferracini; Alessandro Aprato; Alessandro Massè; Walter Daghino; Sara Lea; Stefano Artiaco; Gwo-Chin Lee
Journal:  J Orthop       Date:  2020-08-28

4.  Total Hip Arthroplasty Using Ceramic-on-ceramic Bearing Surfaces: Long-term Assessment of Squeaking Sounds.

Authors:  Min Wook Kim; Sang Min Kim; Young Yool Chung
Journal:  Hip Pelvis       Date:  2018-03-05

5.  Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review.

Authors:  Chen-Chen Zhao; Guo-Xin Qu; Shi-Gui Yan; Xun-Zi Cai
Journal:  J Orthop Surg Res       Date:  2018-06-01       Impact factor: 2.359

6.  Midterm Results of Fourth-Generation Ceramic-On-Ceramic Total Hip Arthroplasty.

Authors:  Kyu-Jin Cho; Kyung-Soon Park; Won-Young Jang; Chun-Gon Park; Taek-Rim Yoon
Journal:  Indian J Orthop       Date:  2019 Sep-Oct       Impact factor: 1.251

7.  Mid-term outcomes of the R3™ delta ceramic acetabular system in total hip arthroplasty.

Authors:  Edward T Davis; Ville Remes; Petri Virolainen; Peter Gebuhr; Bart Van Backlé; Matthew P Revell; Branko Kopjar
Journal:  J Orthop Surg Res       Date:  2021-01-09       Impact factor: 2.359

Review 8.  Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty.

Authors:  Guo-Liang Wu; Wei Zhu; Yan Zhao; Qi Ma; Xi-Sheng Weng
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628

9.  Design of Novel Ceramic Preconcentrator and Integration in Gas Chromatographic System for Detection of Ethylene Gas from Ripening Bananas.

Authors:  Nayyer Abbas Zaidi; Muhammad Waseem Tahir; Micheal J Vellekoop; Walter Lang
Journal:  Sensors (Basel)       Date:  2018-08-07       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.