Literature DB >> 25847685

Microtensile bond strength of a resin-based fissure sealant to Er,Cr:YSGG laser-etched primary enamel.

Elif Sungurtekin-Ekci1, Nurhan Oztas2.   

Abstract

The aim of this study was to evaluate the effect of Er,Cr:YSGG laser pre-treatment alone, or associated with acid-etching, on the microtensile bond strength of a resin-based fissure sealant to primary enamel. Twenty-five human primary molars were randomly divided into five groups including (1) 35 % acid etching, (2) 2.5-W laser etching, (3) 3.5-W laser etching, (4) 2.5-W laser etching + acid etching, and (5) 3.5-W laser etching + acid etching. Er,Cr:YSGG laser was used at a wavelength of 2.780 nm and pulse duration of 140-200 μs with a repetition rate of 20 Hz. Following surface pre-treatment, the fissure sealant (ClinPro™, 3M Dental Products) was applied. Each tooth was sectioned and subjected to microtensile testing. Kruskal-Wallis test was used for statistical analysis. The level of significance was set at p < 0.05. The microtensile bond strength values of group 1 were significantly higher than those of group 2, while no statistically significant difference was detected between groups 1, 3, 4, and 5. It was concluded that 3.5-W laser etching produced results comparable to conventional acid etching technique, whereas 2.5-W laser etching was not able to yield adequate bonding performance.

Entities:  

Keywords:  Acid etching; Er,Cr:YSGG laser; Fissure sealant; Microtensile bond strength; Primary teeth

Mesh:

Substances:

Year:  2015        PMID: 25847685     DOI: 10.1007/s10266-015-0203-8

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  31 in total

1.  Pit and fissure sealing.

Authors:  M G Buonocore
Journal:  Dent Clin North Am       Date:  1975-04

2.  Bonding characteristics of self-etching adhesives to intact versus prepared enamel.

Authors:  Jorge Perdigão; Saulo Geraldeli
Journal:  J Esthet Restor Dent       Date:  2003       Impact factor: 2.843

3.  Microtensile adhesion of sealants to intact enamel.

Authors:  J Perdigão; J W Fundingsland; S Duarte; M Lopes
Journal:  Int J Paediatr Dent       Date:  2005-09       Impact factor: 3.455

4.  Microtensile bond strength to ground enamel by glass-ionomers, resin-modified glass-ionomers, and resin composites used as pit and fissure sealants.

Authors:  Federica Papacchini; Cecilia Goracci; Fernanda Tranchesi Sadek; Francesca Monticelli; Franklin Garcia-Godoy; Marco Ferrari
Journal:  J Dent       Date:  2004-12-20       Impact factor: 4.379

5.  Etching enamel for orthodontics with an erbium, chromium:yttrium-scandium-gallium-garnet laser system.

Authors:  Güvenç Basaran; Törün Ozer; Nükhet Berk; Orhan Hamamci
Journal:  Angle Orthod       Date:  2007-01       Impact factor: 2.079

6.  Shear bond strength of a sealant to contaminated-enamel surface: influence of erbium : yttrium-aluminum-garnet laser pretreatment.

Authors:  Taísa Penazzo Lepri; Aline Evangelista Souza-Gabriel; Juliana Abdallah Atoui; Regina Guenka Palma-Dibb; Jesus Djalma Pécora; Silmara Aparecida Milori Corona
Journal:  J Esthet Restor Dent       Date:  2008       Impact factor: 2.843

7.  Effect of Er,Cr:YSGG laser on the microtensile bond strength of two different adhesives to the sound and caries-affected dentin.

Authors:  Z Ergücü; E U Celik; N Unlü; M Türkün; F Ozer
Journal:  Oper Dent       Date:  2009 Jul-Aug       Impact factor: 2.440

Review 8.  Changes in heated and in laser-irradiated human tooth enamel and their probable effects on solubility.

Authors:  B O Fowler; S Kuroda
Journal:  Calcif Tissue Int       Date:  1986-04       Impact factor: 4.333

9.  Sealant bond strengths of CO(2) laser-etched versus acid-etched bovine enamel.

Authors:  J L Drummond; H A Wigdor; J T Walsh; S Fadavi; I Punwani
Journal:  Lasers Surg Med       Date:  2000       Impact factor: 4.025

10.  Shear bond strength and SEM morphology evaluation of different dental adhesives to enamel prepared with ER:YAG laser.

Authors:  Patrícia T Pires; João C Ferreira; Sofia A Oliveira; Alvaro F Azevedo; Walter R Dias; Paulo R Melo
Journal:  Contemp Clin Dent       Date:  2013-01
View more
  1 in total

1.  Effect of Er:YAG laser enamel conditioning and moisture on the microleakage of a hydrophilic sealant.

Authors:  Zeynep Aslı Güçlü; Andrew Paul Hurt; Nazmiye Dönmez; Nichola Jayne Coleman
Journal:  Odontology       Date:  2017-12-13       Impact factor: 2.634

  1 in total