Literature DB >> 17029548

Etching enamel for orthodontics with an erbium, chromium:yttrium-scandium-gallium-garnet laser system.

Güvenç Basaran1, Törün Ozer, Nükhet Berk, Orhan Hamamci.   

Abstract

OBJECTIVE: To test the shear bond strength, surface characteristics, and fracture mode of brackets that are bonded to enamel etched with an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser operated at different power outputs: 0.5 W, 1 W, and 2 W.
MATERIALS AND METHODS: Human premolars that had been extracted for orthodontic purposes were used. Enamel was etched with an Er,Cr:YSGG laser system operated at one of three power outputs or with orthophosphoric acid.
RESULTS: The shear bond strength associated with the 0.5-W laser irradiation was significantly less than the strengths obtained with the other irradiations. Both the 1-W and 2-W laser irradiations were capable of etching enamel in the same manner. This finding was confirmed by scanning electron microscopy examination. The evaluation of adhesive-remnant-index scores demonstrated no statistically significant difference in bond failure site among the groups, except for the 0.5-W laser-etched group. Generally, more adhesive was left on the enamel surface with laser irradiation than with acid etching.
CONCLUSION: The mean shear bond strength and enamel surface etching obtained with an Er,Cr: YSGG laser (operated at 1 W or 2 W for 15 seconds) is comparable to that obtained with acid etching.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17029548     DOI: 10.2319/120605-426R.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  38 in total

1.  Comparison of microtensile bond strength of a resin composite to enamel conditioned by acid etching and Er,Cr:YSGG laser in human primary teeth.

Authors:  B Malekafzali; R Fekrazad; A Mirfasihi; S Saedi
Journal:  Eur Arch Paediatr Dent       Date:  2014-11-01

2.  Adhesion after erbium, chromium:yttrium-scandium-gallium-garnet laser application at three different irradiation conditions.

Authors:  Sérgio Brossi Botta; Patricia Aparecida da Ana; Denise Maria Zezell; John M Powers; Adriana Bona Matos
Journal:  Lasers Med Sci       Date:  2007-11-20       Impact factor: 3.161

3.  Shear bond strength of metal brackets to feldspathic porcelain treated by Nd:YAG laser and hydrofluoric acid.

Authors:  Mohammad Hashem Hosseini; Farhad Sobouti; Ardavan Etemadi; Nasim Chiniforush; Mahsa Shariati
Journal:  Lasers Med Sci       Date:  2013-10-19       Impact factor: 3.161

4.  Influence of different power outputs of erbium, chromium:yttrium-scandium-gallium-garnet laser and acid etching on shear bond strengths of a dual-cure resin cement to enamel.

Authors:  Emine Göncü Başaran; Emrah Ayna; Güvenç Başaran; Köksal Beydemir
Journal:  Lasers Med Sci       Date:  2009-12-17       Impact factor: 3.161

5.  Effects of laser and acid etching and air abrasion on mineral content of dentin.

Authors:  Meral Arslan Malkoc; Serife Tuba Taşdemir; A Nilgun Ozturk; Bora Ozturk; Gizem Berk
Journal:  Lasers Med Sci       Date:  2010-01-19       Impact factor: 3.161

6.  In vitro evaluation of microleakage under orthodontic brackets using two different laser etching, self etching and acid etching methods.

Authors:  Nihal Hamamci; Atilim Akkurt; Güvenç Başaran
Journal:  Lasers Med Sci       Date:  2009-06-27       Impact factor: 3.161

7.  A Comparison of Shear Bond Strengths of Metal and Ceramic Brackets using Conventional Acid Etching Technique and Er:YAG Laser Etching.

Authors:  Sogra Yassaei; Reza Fekrazad; Neda Shahraki; Mahdjoube Goldani Moghadam
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-03-05

8.  Shear bond strength of bonding to enamel with different laser irradiation distances.

Authors:  Güvenç Başaran; Nihal Hamamcı; Atılım Akkurt
Journal:  Lasers Med Sci       Date:  2010-02-12       Impact factor: 3.161

9.  Microtensile bond strength of a resin-based fissure sealant to Er,Cr:YSGG laser-etched primary enamel.

Authors:  Elif Sungurtekin-Ekci; Nurhan Oztas
Journal:  Odontology       Date:  2015-04-07       Impact factor: 2.634

10.  Comparison of shear bond strength of reattached incisor fragment using Er,Cr:YSGG laser etching and conventional acid etching: An in vitro study.

Authors:  Ferah Rehman; Gyanendra Kumar; Mridula Goswami; Jatinder Kaur Dhillon
Journal:  Laser Ther       Date:  2016-06-29
View more