Literature DB >> 25840815

Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention.

Shigeru Nakamura1, Tomoko Kobayashi2, Atsushi Funatsu2, Tadahisa Okada2, Maria Mauti3, Yuki Waizumi4, Shinichi Yamada4.   

Abstract

Coronary angiography and intervention can expose patients to high radiation dose. This retrospective study quantifies the patient dose reduction due to the introduction of a novel X-ray imaging noise reduction technology using advanced real-time image noise reduction algorithms and optimized acquisition chain for fluoroscopy and exposure in interventional cardiology. Patient, procedure and radiation dose data were retrospectively collected in the period August 2012-August 2013 for 883 patients treated with the image noise reduction technology (referred as "new system"). The same data were collected for 1083 patients in the period April 2011-July 2012 with a system using state-of-the-art image processing and reference acquisition chain (referred as "reference system"). Procedures were divided into diagnostic (CAG) and intervention (PCI). Acquisition parameters such as fluoroscopy time, volume of contrast medium, number of exposure images and number of stored fluoroscopy images were collected to classify procedure complexity. The procedural dose reduction was investigated separately for three main cardiologists. The new system provides significant dose reduction compared to the reference system. Median DAP values decreased for all procedures (p < 0.0001) from 172.7 to 59.4 Gy cm(2), for CAG from 155.1 to 52.0 Gy cm(2) and for PCI from 229.0 to 85.8 Gy cm(2) with reduction quantified at 66, 66 and 63 %, respectively. Based on median values, the dose reduction for all procedures was 68, 60 and 67 % for cardiologists 1, 2 and 3, respectively. The X-ray imaging technology combining advanced real-time image noise reduction algorithms and anatomy-specific optimized fluoroscopy and cine acquisition chain provides 66 % patient dose reduction in interventional cardiology.

Entities:  

Keywords:  DAP; Image processing; Interventional cardiology; Radiation dose; X-ray imaging technology

Mesh:

Substances:

Year:  2015        PMID: 25840815     DOI: 10.1007/s00380-015-0667-z

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  23 in total

Review 1.  Chronic total occlusion angioplasty in the United States.

Authors:  J Aaron Grantham; Steven P Marso; John Spertus; John House; David R Holmes; Barry D Rutherford
Journal:  JACC Cardiovasc Interv       Date:  2009-06       Impact factor: 11.195

2.  Association between deteriorated renal function and long-term clinical outcomes after percutaneous coronary intervention.

Authors:  Manabu Ogita; Kenichi Sakakura; Tomohiro Nakamura; Hiroshi Funayama; Hiroshi Wada; Ryo Naito; Yoshitaka Sugawara; Norifumi Kubo; Junya Ako; Shin-ichi Momomura
Journal:  Heart Vessels       Date:  2011-08-06       Impact factor: 2.037

3.  Sustainability in the cardiac cath lab.

Authors:  Eugenio Picano; Gennaro Santoro; Eliseo Vano
Journal:  Int J Cardiovasc Imaging       Date:  2006-10-11       Impact factor: 2.357

4.  Patient dose values in a dedicated Greek cardiac centre.

Authors:  V Tsapaki; S Kottou; E Vano; K Faulkner; J Giannouleas; R Padovani; E Kyrozi; M Koutelou; E Vardalaki; V Neofotistou
Journal:  Br J Radiol       Date:  2003-10       Impact factor: 3.039

5.  Patient radiation exposure tracking: worldwide programs and needs--results from the first IAEA survey.

Authors:  Madan M Rehani; Donald P Frush; Theocharis Berris; Andrew J Einstein
Journal:  Eur J Radiol       Date:  2012-07-25       Impact factor: 3.528

6.  An investigation of patient doses during coronary interventional procedures in China.

Authors:  Yanhai Cui; Hongdan Zhang; Junhui Zheng; Xiangtai Yang; Changhong Liang
Journal:  Radiat Prot Dosimetry       Date:  2013-03-24       Impact factor: 0.972

7.  The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients--a white paper executive summary.

Authors:  Keith J Strauss; Sue C Kaste
Journal:  Pediatr Radiol       Date:  2006-09

8.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

Review 9.  Contrast media and the kidney: European Society of Urogenital Radiology (ESUR) guidelines.

Authors:  H S Thomsen; S K Morcos
Journal:  Br J Radiol       Date:  2003-08       Impact factor: 3.039

10.  Radiation dose in neuroangiography using image noise reduction technology: a population study based on 614 patients.

Authors:  Michael Söderman; Maria Mauti; Sjirk Boon; Artur Omar; María Marteinsdóttir; Tommy Andersson; Staffan Holmin; Bart Hoornaert
Journal:  Neuroradiology       Date:  2013-09-05       Impact factor: 2.804

View more
  9 in total

1.  Can image enhancement allow radiation dose to be reduced whilst maintaining the perceived diagnostic image quality required for coronary angiography?

Authors:  Anuja Joshi; Amber J Gislason-Lee; Claire Keeble; Uduvil M Sivananthan; Andrew G Davies
Journal:  Br J Radiol       Date:  2017-01-26       Impact factor: 3.039

2.  Noise reduction technology reduces radiation dose in chronic total occlusions percutaneous coronary intervention: a propensity score-matched analysis.

Authors:  Davide Maccagni; Susanna Benincasa; Barbara Bellini; Luciano Candilio; Enrico Poletti; Mauro Carlino; Antonio Colombo; Lorenzo Azzalini
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-23       Impact factor: 2.357

3.  Comprehensive assessment of patient image quality and radiation dose in latest generation cardiac x-ray equipment for percutaneous coronary interventions.

Authors:  Amber J Gislason-Lee; Claire Keeble; Daniel Egleston; Josephine Bexon; Stephen M Kengyelics; Andrew G Davies
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-02

4.  Reduced Patient Radiation Exposure during Neurodiagnostic and Interventional X-Ray Angiography with a New Imaging Platform.

Authors:  K van der Marel; S Vedantham; I M J van der Bom; M Howk; T Narain; K Ty; A Karellas; M J Gounis; A S Puri; A K Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2017-01-19       Impact factor: 3.825

5.  Radiation doses during cardiac catheterisation procedures in India: a multicentre study: Radiation dose study.

Authors:  Vijayakumar Subban; Sophie Amelot; Suma M Victor; Anil Potdar; Vishawanath Yadav; Tejas Patel; Sanjay Shah; Thomas Alexander; Balakumaran Jeyakumaran; Juno Angel; Mullasari S Ajit
Journal:  AsiaIntervention       Date:  2020-07-20

6.  Impact of latest generation cardiac interventional X-ray equipment on patient image quality and radiation dose for trans-catheter aortic valve implantations.

Authors:  Amber J Gislason-Lee; Claire Keeble; Christoper J Malkin; Daniel Egleston; Josephine Bexon; Stephen M Kengyelics; Daniel Blackman; Andrew G Davies
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

7.  Impact of new X-ray technology on patient dose in pacemaker and implantable cardioverter defibrillator (ICD) implantations.

Authors:  Joris D van Dijk; Jan Paul Ottervanger; Peter Paul H M Delnoy; Martine C M Lagerweij; Siert Knollema; Cornelis H Slump; Pieter L Jager
Journal:  J Interv Card Electrophysiol       Date:  2016-10-26       Impact factor: 1.900

Review 8.  Current State and Future Perspectives of Artificial Intelligence for Automated Coronary Angiography Imaging Analysis in Patients with Ischemic Heart Disease.

Authors:  Mitchel A Molenaar; Jasper L Selder; Johny Nicolas; Bimmer E Claessen; Roxana Mehran; Javier Oliván Bescós; Mark J Schuuring; Berto J Bouma; Niels J Verouden; Steven A J Chamuleau
Journal:  Curr Cardiol Rep       Date:  2022-03-28       Impact factor: 2.931

9.  An AnteOwl WR intravascular ultrasound-guided parallel wiring technique for chronic total occlusion of below-the-knee arteries.

Authors:  Naoki Hayakawa; Satoshi Kodera; Satoshi Hirano; Masataka Arakawa; Yasunori Inoguchi; Junji Kanda
Journal:  CVIR Endovasc       Date:  2022-03-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.