Literature DB >> 21173702

Influence of cataract on time domain and spectral domain optical coherence tomography retinal nerve fiber layer measurements.

Na Rae Kim1, Hun Lee, Eun Suk Lee, Ji Hyun Kim, Samin Hong, Gong Je Seong, Chan Yun Kim.   

Abstract

PURPOSE: To assess and compare the influence of cataract on measurements of retinal nerve fiber layer (RNFL) thickness by time domain (TD) optical coherence tomography (OCT) and spectral domain (SD) OCT.
METHODS: Patients who underwent uncomplicated cataract surgery were consecutively enrolled in this study. The peripapillary RNFL thickness was measured before and 8 weeks after cataract surgery using TD-OCT and SD-OCT during the same visit. Changes in the RNFL thickness measurement and signal strength (SS) after cataract surgery were evaluated.
RESULTS: A total of 54 patients (54 eyes) were included. After excluding 19 eyes owing to poor imaging or low SS (<5), scans of 35 eyes were included in the final analysis. A significant difference was identified between the preoperative and postoperative SS values using SD-OCT, but not TD-OCT (P=0.002 and 0.789, respectively). The changes in RNFL thickness after cataract surgery were more prominent and frequent for SD-OCT than TD-OCT. There was a significant correlation between change in preoperative RNFL thickness and SS changes for both TD-OCT (r=0.410, P<0.001) and SD-OCT (r=0.246, P=0.002).
CONCLUSIONS: The presence of cataract significantly affects RNFL thickness measurements by SD-OCT and TD-OCT. SD-OCT, which demonstrated more consistent change of RNFL measurements after cataract extraction, is not necessarily associated with lower RNFL thickness measurement performance in cataract cases, as more participants with cataract were excluded because of poor image quality or low SS, which was more associated with TD-OCT than SD-OCT.

Entities:  

Mesh:

Year:  2012        PMID: 21173702     DOI: 10.1097/IJG.0b013e31820277da

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  18 in total

1.  Comparison of the current and a new RTVue OCT software version for detection of ganglion cell complex changes due to cataract surgery.

Authors:  Gábor Holló; Farzaneh Naghizadeh; Sofia Hsu; Tamás Filkorn; Mária Bausz
Journal:  Int Ophthalmol       Date:  2015-03-27       Impact factor: 2.031

2.  Optical Coherence Tomography Segmentation Errors of the Retinal Nerve Fiber Layer Persist Over Time.

Authors:  Nisha Nagarkatti-Gude; Stuart K Gardiner; Brad Fortune; Shaban Demirel; Steven L Mansberger
Journal:  J Glaucoma       Date:  2019-05       Impact factor: 2.503

3.  Combined depth imaging technique on spectral-domain optical coherence tomography.

Authors:  Giulio Barteselli; Dirk-Uwe Bartsch; Sharif El-Emam; Maria Laura Gomez; Jay Chhablani; Su Na Lee; Laura Conner; William R Freeman
Journal:  Am J Ophthalmol       Date:  2012-12-17       Impact factor: 5.258

4.  Using Retinal Imaging to Study Dementia.

Authors:  Victor T T Chan; Tiffany H K Tso; Fangyao Tang; Clement Tham; Vincent Mok; Christopher Chen; Tien Y Wong; Carol Y Cheung
Journal:  J Vis Exp       Date:  2017-11-06       Impact factor: 1.355

5.  Changes in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation.

Authors:  Javier García-Bella; Paula Talavero-González; Jesús Carballo-Álvarez; Juan C Sanz-Fernández; José M Vázquez-Moliní; Julián García-Feijóo; José M Martínez-de-la-Casa
Journal:  Eye (Lond)       Date:  2018-06-11       Impact factor: 3.775

6.  Longitudinal analysis of retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in ethambutol-induced optic neuropathy.

Authors:  Jinu Han; Min Kwang Byun; Junwon Lee; So Young Han; Jong Bok Lee; Sueng-Han Han
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-09-07       Impact factor: 3.117

Review 7.  Factors Affecting Cirrus-HD OCT Optic Disc Scan Quality: A Review with Case Examples.

Authors:  Joshua S Hardin; Giovanni Taibbi; Seth C Nelson; Diana Chao; Gianmarco Vizzeri
Journal:  J Ophthalmol       Date:  2015-08-13       Impact factor: 1.909

8.  Reproducibility of peripapillary retinal nerve fiber layer thickness measured by spectral domain optical coherence tomography in pseudophakic eyes.

Authors:  Gyu Ah Kim; Ji Hyun Kim; Jun Mo Lee; Kyoung Soo Park
Journal:  Korean J Ophthalmol       Date:  2014-03-14

9.  Effect of Signal Intensity on Measurement of Ganglion Cell Complex and Retinal Nerve Fiber Layer Scans in Fourier-Domain Optical Coherence Tomography.

Authors:  Xinbo Zhang; Shawn M Iverson; Ou Tan; David Huang
Journal:  Transl Vis Sci Technol       Date:  2015-10-01       Impact factor: 3.283

10.  Retinal Thickness and the Structure/Function Relationship in the Eyes of Older Adults with Glaucoma.

Authors:  Megumi Honjo; Kazuko Omodaka; Tatsuro Ishizaki; Shinji Ohkubo; Makoto Araie; Toru Nakazawa
Journal:  PLoS One       Date:  2015-10-27       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.