| Literature DB >> 25791781 |
Rene Seiger1, Andreas Hahn1, Allan Hummer2, Georg S Kranz1, Sebastian Ganger1, Martin Küblböck2, Christoph Kraus1, Ronald Sladky2, Siegfried Kasper1, Christian Windischberger2, Rupert Lanzenberger3.
Abstract
Recent technological progress enables MRI recordings at ultra-high fields of 7 T and above leading to brain images of higher resolution and increased signal-to-noise ratio. Despite these benefits, imaging at 7 T exhibits distinct challenges due to B1 field inhomogeneities, causing decreased image quality and problems in data analysis. Although several strategies have been proposed, a systematic investigation of bias-corrected 7 T data for voxel-based morphometry (VBM) is still missing and it is an ongoing matter of debate if VBM at 7 T can be carried out properly. Here, an optimized VBM study was conducted, evaluating the impact of field strength (3T vs. 7 T) and pulse sequence (MPRAGE vs. MP2RAGE) on gray matter volume (GMV) estimates. More specifically, twenty-two participants were measured under the conditions 3T MPRAGE, 7 T MPRAGE and 7 T MP2RAGE. Due to the fact that 7 T MPRAGE data exhibited strong intensity inhomogeneities, an alternative preprocessing pipeline was proposed and applied for that data. VBM analysis revealed higher GMV estimates for 7 T predominantly in superior cortical areas, caudate nucleus, cingulate cortex and the hippocampus. On the other hand, 3T yielded higher estimates especially in inferior cortical areas of the brain, cerebellum, thalamus and putamen compared to 7 T. Besides minor exceptions, these results were observed for 7 T MPRAGE as well for the 7 T MP2RAGE measurements. Results gained in the inferior parts of the brain should be taken with caution, as native GM segmentations displayed misclassifications in these regions for both 7 T sequences. This was supported by the test-retest measurements showing highest variability in these inferior regions of the brain for 7 T and also for the advanced MP2RAGE sequence. Hence, our data support the use of 7 T MRI for VBM analysis in cortical areas, but direct comparison between field strengths and sequences requires careful assessment. Similarly, analysis of the inferior cortical regions, cerebellum and subcortical regions still remains challenging at 7 T even if the advanced MP2RAGE sequence is used.Entities:
Keywords: 7Tesla; MP2RAGE; MPRAGE; Test–retest; Ultra-high field; VBM
Mesh:
Year: 2015 PMID: 25791781 PMCID: PMC5341769 DOI: 10.1016/j.neuroimage.2015.03.019
Source DB: PubMed Journal: Neuroimage ISSN: 1053-8119 Impact factor: 6.556