| Literature DB >> 25775478 |
Liat Gantz1, Shlomo Schrader2, Ruthie Ruben3, Ari Z Zivotofsky4.
Abstract
PURPOSE: A primary task of the eye care professional is determining the refraction, or optical correction, of a patient. The duochrome red-green test is a standard tool for verification of the final refraction. Traditionally, it is recommended for use both prior to and subsequent to determining the cylindrical or astigmatic component of the refraction. In order for it to be effective when used before correcting the cylinder it is necessary that the COLC (Circle of Least Confusion) be on the retina. This study examined whether it is necessarily true that the duochrome response in uncorrected astigmatism will be as trust-worthy as it is with corrected cylinders.Entities:
Mesh:
Year: 2015 PMID: 25775478 PMCID: PMC4361575 DOI: 10.1371/journal.pone.0118874
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Subject demographic and optometric details.
| Subject # | Age | Gender | OD Rx | OD_SPH INTERVAL | OD_SPH+CYL INTERVAL | DIFF BTW INTERVALS |
|---|---|---|---|---|---|---|
| 1 | 20 | F | -1.00/-1.00 X 085 | 1 | 0.5 | 0.5 |
| 2 | 21 | F | -4.25/-0.50X065 | 0.25 | 0.25 | 0 |
| 3 | 21 | F | -1.75/-1.75X095 | 0.25 | 0.5 | -0.25 |
| 4 | 21 | F | -5.00/-0.75X005 | 1.25 | 0.5 | 0.75 |
| 5 | 21 | F | 0.25/-0.25 X 180 | 1 | 0.75 | 0.25 |
| 6 | 21 | F | -4.25/-0.75 X 060 | 0.5 | 0.75 | -0.25 |
| 7 | 21 | M | -0.25 SPH | 0.75 | 0.5 | 0.25 |
| 8 | 21 | M | -3.75/-0.25 X 095 | 0.25 | 0.25 | 0 |
| 9 | 21 | M | -3.50 SPH | 0.5 | 0.5 | 0 |
| 10 | 22 | F | -4.00/-1.50 X 075 | 0.5 | 0.5 | 0 |
| 11 | 22 | F | -11.50/-1.25 X 020 | 0.75 | 0.5 | 0.25 |
| 12 | 22 | F | -3.25/-1.25 X 165 | 0.5 | 0.25 | 0.25 |
| 13 | 22 | F | -3.75/-0.75 X 070 | 0.75 | 0.25 | 0.5 |
| 14 | 22 | M | -0.50/-0.50 X 105 | 0.25 | 0.25 | 0 |
| 15 | 22 | M | -4.25/ -0.50 X 010 | 0.25 | 0.5 | -0.25 |
| 16 | 22 | M | -5.00/-0.25 X 010 | 0.5 | 0.5 | 0 |
| 17 | 23 | F | -0.25 SPH | 0.25 | 0.5 | -0.25 |
| 18 | 24 | M | -6.00/-0.75 X 125 | 1 | 1.75 | -0.75 |
| 19 | 25 | F | -6.75/-1.00 X 010 | 1 | 2 | -1 |
| 20 | 26 | F | Plano/-0.50 X 030 | 0.5 | 0.75 | -0.25 |
| 21 | 26 | M | -2.00 SPH | 1 | 0.5 | 0.5 |
| 22 | 26 | M | 0.50/-2.00 X 090 | 0.5 | 0.75 | -0.25 |
| 23 | 28 | M | Plano/ -0.50 X 100 | 1 | 1 | 0 |
| 24 | 29 | F | -3.00/-0.50 X 120 | 1.25 | 1.25 | 0 |
| 25 | 38 | M | +3.50/ -2.00 X 090 | 0.25 | 0.25 | 0 |
| 26 | 56 | M | -5.00 SPH | 0.5 | 0.5 | 0 |
Fig 1Bar graph of red-green interval.
The X axis is subject number and Y axis is the interval between “red” and “green” responses in diopters. Blue is with spherical correction only; red is with spherical and cylindrical correction.