Literature DB >> 3061448

Stabilisation of refraction following cataract surgery.

P R Baranyovits1.   

Abstract

Refraction was performed at frequent, regular intervals for six months following routine intracapsular cataract extraction. Patients were divided into two groups, those whose limbal sections were closed with 8-0 virgin silk or with 9-0 nylon. The stabilisation of refraction was observed, and the most suitable time to prescribe 'first glasses' was estimated retrospectively. In the silk group this was found to be at three months in the nylon group at four months. However, results in the latter were less predictable with greater variation.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3061448      PMCID: PMC1041597          DOI: 10.1136/bjo.72.11.815

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  6 in total

1.  Changes in the corneal curvature following cataract extraction.

Authors:  G FLOYD
Journal:  Am J Ophthalmol       Date:  1951-11       Impact factor: 5.258

2.  Control of astigmatism by wound placement.

Authors:  B H Thrasher; C F Boerner
Journal:  J Am Intraocul Implant Soc       Date:  1984

3.  Astigmatism following cataract surgery.

Authors:  V M Reading
Journal:  Br J Ophthalmol       Date:  1984-02       Impact factor: 4.638

4.  Keratometric changes after cataract extraction.

Authors:  D Singh; K Kumar
Journal:  Br J Ophthalmol       Date:  1976-09       Impact factor: 4.638

5.  The natural and modified course of post-cataract astigmatism.

Authors:  G A Stainer; P S Binder; W T Parker; T Perl
Journal:  Ophthalmic Surg       Date:  1982-10

6.  Changes in corneal curvature induced by sutures and incisions.

Authors:  G van Rij; G O Waring
Journal:  Am J Ophthalmol       Date:  1984-12-15       Impact factor: 5.258

  6 in total
  3 in total

1.  Stabilisation of refraction following extracapsular cataract extraction.

Authors:  P Baranyovits
Journal:  Br J Ophthalmol       Date:  1990-08       Impact factor: 4.638

2.  Can the red-green duochrome test be used prior to correcting the refractive cylinder component?

Authors:  Liat Gantz; Shlomo Schrader; Ruthie Ruben; Ari Z Zivotofsky
Journal:  PLoS One       Date:  2015-03-16       Impact factor: 3.240

3.  Stabilization of refractive error and associated factors following small incision phacoemulsification cataract surgery.

Authors:  Ammar M Khan; Derek M Waldner; Micah Luong; Emi Sanders; Andrew C S Crichton; Bryce A Ford
Journal:  BMC Ophthalmol       Date:  2022-01-06       Impact factor: 2.209

  3 in total