Literature DB >> 25773371

Evaluation of measurement and stimulation patterns in open electrical impedance tomography with scanning electrode.

Jinzhen Liu1, Hui Xiong, Ling Lin, Gang Li.   

Abstract

The reconstruction quality in electrical impedance tomography is limited by the current injection amplitude, the injection and measurement patterns, and the measurement accuracy as well as the number and placement of electrodes. This paper dedicates to increase the number of independent voltage measurements by scanning electrode (SE), and design an optimal measurement and stimulation pattern for open electrical impedance tomography (OEIT). Firstly, several measurement patterns are, performed in OEIT, aiming to evaluate the right number of the measurement points for the imaged target in a certain depth. The results indicate that the image quality gets higher with the number of measurement point increased to some extent. Thus, it can guide the optimum design for the electrode system in OEIT. Secondly, through the numerical calculation and salt water tank experiment, in contrast to adjacent current injection pattern, cross-current-injection pattern achieves better reconstruction with higher imaging quality and penetration depth, and is more robust against data noise in deep domain. Lastly, the experiments also indicate that the electrode contact area affects the reconstruction quality and investigation depth. Therefore, OEIT with SE can improve the application in clinic, such as the detection and monitoring of vascular, breast, and pulmonary diseases.

Entities:  

Mesh:

Year:  2015        PMID: 25773371     DOI: 10.1007/s11517-015-1274-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arrays.

Authors:  J L Mueller; D Isaacson; J C Newell
Journal:  IEEE Trans Biomed Eng       Date:  1999-11       Impact factor: 4.538

2.  The number of electrodes and basis functions in EIT image reconstruction.

Authors:  Mengxing Tang; Wei Wang; James Wheeler; Malcolm McCormick; Xiuzhen Dong
Journal:  Physiol Meas       Date:  2002-02       Impact factor: 2.833

Review 3.  Whither lung EIT: where are we, where do we want to go and what do we need to get there?

Authors:  Andy Adler; Marcelo B Amato; John H Arnold; Richard Bayford; Marc Bodenstein; Stephan H Böhm; Brian H Brown; Inéz Frerichs; Ola Stenqvist; Norbert Weiler; Gerhard K Wolf
Journal:  Physiol Meas       Date:  2012-04-24       Impact factor: 2.833

4.  Anatomically accurate hard priors for transrectal electrical impedance tomography (TREIT) of the prostate.

Authors:  H Syed; A Borsic; A Hartov; R J Halter
Journal:  Physiol Meas       Date:  2012-04-24       Impact factor: 2.833

5.  Evaluation of different stimulation and measurement patterns based on internal electrode: application in cardiac impedance tomography.

Authors:  J Nasehi Tehrani; T I Oh; C Jin; A Thiagalingam; A McEwan
Journal:  Comput Biol Med       Date:  2012-09-25       Impact factor: 4.589

6.  In vivo impedance imaging with total variation regularization.

Authors:  Andrea Borsic; Brad M Graham; Andy Adler; William R B Lionheart
Journal:  IEEE Trans Med Imaging       Date:  2010-01       Impact factor: 10.048

7.  Adjacent stimulation and measurement patterns considered harmful.

Authors:  Andy Adler; Pascal Olivier Gaggero; Yasheng Maimaitijiang
Journal:  Physiol Meas       Date:  2011-06-07       Impact factor: 2.833

8.  Assessment of errors in static electrical impedance tomography with adjacent and trigonometric current patterns.

Authors:  V Kolehmainen; M Vauhkonen; P A Karjalainen; J P Kaipio
Journal:  Physiol Meas       Date:  1997-11       Impact factor: 2.833

9.  Image reconstruction based on L1 regularization and projection methods for electrical impedance tomography.

Authors:  Qi Wang; Huaxiang Wang; Ronghua Zhang; Jinhai Wang; Yu Zheng; Ziqiang Cui; Chengyi Yang
Journal:  Rev Sci Instrum       Date:  2012-10       Impact factor: 1.523

  9 in total
  3 in total

1.  Absolute Reconstructions Using Rotational Electrical Impedance Tomography for Breast Cancer Imaging.

Authors:  Ethan K Murphy; Aditya Mahara; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2016-12-15       Impact factor: 10.048

2.  A Multitasking Electrical Impedance Tomography System Using Titanium Alloy Electrode.

Authors:  Abdalla Salama; Amin Malekmohammadi; Shahram Mohanna; Rajprasad Rajkumar
Journal:  Int J Biomed Imaging       Date:  2017-10-31

3.  Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation.

Authors:  Yu Wang; Shangjie Ren; Feng Dong
Journal:  Sensors (Basel)       Date:  2019-05-02       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.