Literature DB >> 11876226

The number of electrodes and basis functions in EIT image reconstruction.

Mengxing Tang1, Wei Wang, James Wheeler, Malcolm McCormick, Xiuzhen Dong.   

Abstract

In electrical impedance tomography, many factors affect the image reconstruction results. Among them are the number of electrodes (NOE) and the number of conductivity basis functions (NOCBF) for image reconstruction. The NOCBF generally reflects the density of the mesh with which images are reconstructed. How and to what extent do these factors affect the image reconstruction and corresponding images? In this area detailed analysis is still lacking. This study aims to address the above question. In this study, image reconstruction and its ill-posed condition were analysed by singular value decomposition (SVD) and spectral expansion theory with different configurations of NOE and NOCBF. The results in this study indicate that for a circular 2D plane object with electrodes evenly located around the boundary: (1) Under certain conditions, increasing the NOE enables us to improve the ill-posed condition in image reconstruction and hence improve the image quality. Generally more improvement is expected near the image periphery than in the image centre. (2) Increasing the NOCBF generally worsens the ill-posed condition. But it enables the solution to be sought in a finer subspace and may be able to improve the image quality on the periphery, while generally the result in image centre depends more on the prior information incorporated in the regularization.

Entities:  

Mesh:

Year:  2002        PMID: 11876226     DOI: 10.1088/0967-3334/23/1/312

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Evaluation of measurement and stimulation patterns in open electrical impedance tomography with scanning electrode.

Authors:  Jinzhen Liu; Hui Xiong; Ling Lin; Gang Li
Journal:  Med Biol Eng Comput       Date:  2015-03-13       Impact factor: 2.602

Review 2.  Electrical Impedance Tomography Technical Contributions for Detection and 3D Geometric Localization of Breast Tumors: A Systematic Review.

Authors:  Juan Carlos Gómez-Cortés; José Javier Díaz-Carmona; José Alfredo Padilla-Medina; Alejandro Espinosa Calderon; Alejandro Israel Barranco Gutiérrez; Marcos Gutiérrez-López; Juan Prado-Olivarez
Journal:  Micromachines (Basel)       Date:  2022-03-23       Impact factor: 3.523

Review 3.  A Review of EMG-, FMG-, and EIT-Based Biosensors and Relevant Human-Machine Interactivities and Biomedical Applications.

Authors:  Zhuo Zheng; Zinan Wu; Runkun Zhao; Yinghui Ni; Xutian Jing; Shuo Gao
Journal:  Biosensors (Basel)       Date:  2022-07-12

4.  Improved Sensing Pulses for Increased Human Head Depth Measurement Sensitivity With Electrical Impedance Spectroscopy.

Authors:  Giorgio Bonmassar; Michael H Lev
Journal:  IEEE Trans Biomed Eng       Date:  2013-09-10       Impact factor: 4.538

5.  Frequency-division multiplexing for electrical impedance tomography in biomedical applications.

Authors:  Yair Granot; Antoni Ivorra; Boris Rubinsky
Journal:  Int J Biomed Imaging       Date:  2007
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.