| Literature DB >> 25759835 |
Marianor Mahat1, Wan Zaidah Abdullah1, Che Maraina Che Hussin2.
Abstract
Measurement of von Willebrand factor antigen (VWF : Ag) levels is usually performed in a specialised laboratory which limits its application in routine clinical practice. So far, no commercial rapid test kit is available for VWF : Ag estimation. This paper discusses the technical aspect of latex agglutination method which was established to suit the purpose of estimating von Willebrand factor (VWF) levels in the plasma sample. The latex agglutination test can be performed qualitatively and semiquantitatively. Reproducibility, stability, linearity, limit of detection, interference, and method comparison studies were conducted to evaluate the performance of this test. Semiquantitative latex agglutination test was strongly correlated with the reference immunoturbidimetric assay (Spearman's rho = 0.946, P < 0.001, n = 132). A substantial agreement (κ = 0.77) was found between qualitative latex agglutination test and the reference assay. Using the scoring system for the rapid latex test, no agglutination is with 0% VWF : Ag (control negative), 1+ reaction is equivalent to <20% VWF : Ag, and 4+ reaction indicates >150% VWF : Ag (when comparing with immunoturbidimetric assay). The findings from evaluation studies suggest that latex agglutination method is suitable to be used as a rapid test kit for the estimation of VWF : Ag levels in various clinical conditions associated with high levels and low levels of VWF : Ag.Entities:
Mesh:
Substances:
Year: 2014 PMID: 25759835 PMCID: PMC4352515 DOI: 10.1155/2014/850810
Source DB: PubMed Journal: J Immunol Res ISSN: 2314-7156 Impact factor: 4.818
Figure 1Positive (number 5) and negative (number 6) reactions of qualitative latex agglutination test for VWF : Ag.
Test score for qualitative latex agglutination test for VWF : Ag.
| Test score | Size of the agglutinated beads | Appearance of the background | Rapidity of the agglutination |
|---|---|---|---|
| 1+ | Small clumps | Cloudy | >2 min |
| 2+ | Small clumps | Cloudy | >1 min |
| 3+ | Small/large clumps | Clear | >30 sec |
| 4+ | Large clumps | Clear | <30 sec |
VWF : Ag: von Willebrand factor antigen.
Estimated concentration of adsorbed antibody in the VWF antibody-latex reagents.
| Initial volume of antibody ( | Initial concentration of antibody ( | Concentration of unadsorbed antibody ( | Concentration of adsorbed antibody ( | Percentage of adsorbed antibody (%) |
|---|---|---|---|---|
| 100 | 310 | 192 | 118 | 38 |
| 150 | 465 | 189 | 276 | 59 |
| 162 | 502 | 174 | 328 | 65 |
| 200 | 620 | 184 | 436 | 70 |
| 226 | 700 | 180 | 520 | 74 |
VWF: von Willebrand factor.
Linearity study on semiquantitative VWF antigen by latex agglutination test.
| Tube number | Sample 1 | Sample 2 | ||
|---|---|---|---|---|
| VWF : Ag (%)a | VWF : Ag (titre)b | VWF : Ag (%)a | VWF : Ag (titre)b | |
| 1 | 600 | 1 : 128 | 460 | 1 : 64 |
| 2 | 300 | 1 : 64 | 230 | 1 : 32 |
| 3 | 150 | 1 : 32 | 115 | 1 : 16 |
| 4 | 86.9 | 1 : 16 | 57.9 | 1 : 8 |
| 5 | 22.2 | 1 : 8 | 27.9 | 1 : 4 |
| 6 | 9.9 | 1 : 4 | 17.6 | 1 : 2 |
aVWF : Ag levels (%) measured by immunoturbidimetric assay using Hemosil von Willebrand Factor Antigen kit from Instrumentation Laboratory, Italy.
bVWF : Ag (titre) estimated by using semiquantitative latex agglutination test.
VWF: von Willebrand factor; VWF : Ag: von Willebrand factor antigen.
Limit of detection of VWF antigen detected by using latex agglutination test.
| Sample/sample number | Neat | 1 : 2 | 1 : 4 | 1 : 8 | ||||
|---|---|---|---|---|---|---|---|---|
| VWF : Ag (%)a | LATe | VWF : Ag (%)b | LATe | VWF : Ag (%)c | LATe | VWF : Ag (%)d | LATe | |
| 1 | 24.2 | + | 12.1 | + | 6.1 | + | 3.0 | − |
| 2 | 20.2 | + | 10.2 | + | 5.1 | + | 2.5 | − |
| 3 | 30.6 | + | 15.3 | + | 6.9 | + | 3.8 | − |
| 4 | 27.6 | + | 13.8 | + | 6.9 | + | 3.4 | − |
| 5 | 26.9 | + | 13.3 | + | 6.7 | + | 3.4 | − |
| 6 | 29.1 | + | 14.6 | + | 7.3 | + | 3.6 | − |
| 7 | 30.3 | + | 15.2 | + | 7.6 | + | 3.8 | − |
aVWF : Ag levels in neat sample that was measured by immunoturbidimetric assay using Hemosil von Willebrand Factor Antigen kit from Instrumentation Laboratory, Italy.
b,c,dEstimated VWF : Ag levels in 1 : 2, 1 : 4, and 1 : 8 diluted samples (i.e., by dividing the VWF : Ag levels of neat sample by the dilution factors of 2, 4, and 8, respectively.
ePositive (+) and negative (−) reactions observed when neat and diluted samples were tested by using latex agglutination test.
VWF : Ag: von Willebrand factor antigen; LAT: latex agglutination test.
Rheumatoid factor interference on high and low plasma pools.
| Type of the plasma pool | Vol. of RF control serum (μL)a | Vol. of the plasma pool (μL) | RF conc. in plasma pool (IU/mL) | vWF LAT (titre) |
|---|---|---|---|---|
| High plasma pool | 25 | 175 | 129 | 1 : 64 |
| 30 | 180 | 147 | 1 : 128 (weak) | |
| 40 | 200 | 172 | 1 : 128 | |
|
| ||||
| Low plasma pool | 10 | 990 | 10 | 1 : 2 |
| 10 | 390 | 26 | 1 : 4 | |
| 10 | 190 | 52 | 1 : 8 | |
| 10 | 90 | 103 | 1 : 16 | |
| 10 | 70 | 129 | 1 : 32 | |
aRheumatoid factor control serum from MyBioSource, USA (1030 IU/mL), was used to spike plasma pools.
RF: rheumatoid factor; VWF LAT: von Willebrand factor latex agglutination test; vol., volume; conc., concentration.
Crosstabulation of VWF antigen levels and qualitative VWF by latex agglutination test results.
| Qualitative VWF latex agglutination test (LAT score) | Total | ||||
|---|---|---|---|---|---|
| 1+ | 2+ | 3+ | 4+ | ||
| VWF : Ag levels by immunoturbidimetric assay (%) | |||||
| <20 | 6 | 1 | 0 | 0 | 7 |
| 20–50 | 0 | 12 | 0 | 0 | 12 |
| 50–150 | 0 | 1 | 46 | 2 | 49 |
| >150 | 0 | 0 | 15 | 49 | 64 |
|
| |||||
| Total | 6 | 14 | 61 | 51 | 132 |
VWF: von Willebrand factor; VWF : Ag, von Willebrand factor antigen; LAT: latex agglutination test.
Correlation of result interpretations by latex agglutination test and immunoturbidimetric assay.
| Qualitative latex agglutination test (LAT score) | Semiquantitative latex agglutination test (titre) | VWF : Ag levels by immunoturbidimetric assay (%) |
|---|---|---|
| 1+ | 1 : 2 | <20 |
| 2+ | 1 : 4, 1 : 8 | 20–50 |
| 3+ | 1 : 16, 1 : 32 | 50–150 |
| 4+ | ≥64 | >150 |
The proposed interpretation guide: normal level of VWF : Ag is indicated by LAT scores of 2+ and 3+ or titres from 1 : 8 to 1 : 32. Abnormal low VWF : Ag is indicated by LAT scores of 0, 1+, and 2+ or titres of 1 : 2 and 1 : 4. Abnormal high VWF : Ag is indicated by LAT score of 4+ or titres of ≥64.
LAT: latex agglutination test; VWF : Ag: von Willebrand factor antigen.