Literature DB >> 28843787

A rapid ultrasound particle agglutination method for HIV antibody detection: Comparison with conventional rapid HIV tests.

Simon Bystryak1, Natalya Ossina2.   

Abstract

We present the results of the feasibility and preliminary studies on analytical performance of a rapid test for detection of human immunodeficiency virus (HIV) antibodies in human serum or plasma that is an important advance in detecting HIV infection. Current methods for rapid testing of antibodies against HIV are qualitative and exhibit poor sensitivity (limit of detection). In this paper, we describe an ultrasound particle agglutination (UPA) method that leads to a significant increase of the sensitivity of conventional latex agglutination tests for HIV antibody detection in human serum or plasma. The UPA method is based on the use of: 1) a dual mode ultrasound, wherein a first single-frequency mode is used to accelerate the latex agglutination process, and then a second swept-frequency mode of sonication is used to disintegrate non-specifically bound aggregates; and 2) a numerical assessment of results of the agglutination process. The numerical assessment is carried out by optical detection and analysis of moving patterns in the resonator cell during the swept-frequency mode. The single-step UPA method is rapid and more sensitive than the three commercial rapid HIV test kits analyzed in the study: analytical sensitivity of the new UPA method was found to be 510-, 115-, and 80-fold higher than that for Capillus™, Multispot™ and Uni-Gold™ Recombigen HIV antibody rapid test kits, respectively. The newly developed UPA method opens up additional possibilities for detection of a number of clinically significant markers in point-of-care settings.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  HIV antibody rapid test; Immunoassay; Particle agglutination; Ultrasound

Mesh:

Substances:

Year:  2017        PMID: 28843787      PMCID: PMC5623126          DOI: 10.1016/j.jviromet.2017.08.015

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  59 in total

1.  Use of HIV-1 p24 as a sensitive, precise and inexpensive marker for infection, disease progression and treatment failure.

Authors:  J Schüpbach; Z Tomasik; D Nadal; B Ledergerber; M Flepp; M Opravil; J Böni
Journal:  Int J Antimicrob Agents       Date:  2000-12       Impact factor: 5.283

2.  Rapid particle agglutination test for human immunodeficiency virus: hospital-based evaluation.

Authors:  Sandeep Ramalingam; Rajesh Kannangai; Antony Raj A; Mary V Jesudason; Gopalan Sridharan
Journal:  J Clin Microbiol       Date:  2002-04       Impact factor: 5.948

Review 3.  Ultrasonic enhancement of bead-based bioaffinity assays.

Authors:  M Wiklund; H M Hertz
Journal:  Lab Chip       Date:  2006-08-08       Impact factor: 6.799

4.  Rapid agglutination testing in an ultrasonic standing wave.

Authors:  M A Grundy; W E Bolek; W T Coakley; E Benes
Journal:  J Immunol Methods       Date:  1993-09-27       Impact factor: 2.303

5.  Attempts to enhance light microscopic diagnosis of cutaneous T-cell lymphoma (mycosis fungoides).

Authors:  W P Lefeber; J K Robinson; W E Clendenning; J L Dunn; T Colton
Journal:  Arch Dermatol       Date:  1981-07

6.  Quantitative nephelometric assay for determining myoglobin evaluated.

Authors:  J R Delanghe; J P Chapelle; S C Vanderschueren
Journal:  Clin Chem       Date:  1990-09       Impact factor: 8.327

7.  Enzyme immunoassay using a novel recombinant polypeptide to detect human immunodeficiency virus env antibody.

Authors:  R M Thorn; G A Beltz; C H Hung; B F Fallis; S Winkle; K L Cheng; D J Marciani
Journal:  J Clin Microbiol       Date:  1987-07       Impact factor: 5.948

8.  Assessment of the ability of a fourth-generation immunoassay for human immunodeficiency virus (HIV) antibody and p24 antigen to detect both acute and recent HIV infections in a high-risk setting.

Authors:  Mark W Pandori; John Hackett; Brian Louie; Ana Vallari; Teri Dowling; Sally Liska; Jeffrey D Klausner
Journal:  J Clin Microbiol       Date:  2009-06-17       Impact factor: 5.948

9.  Evaluation of the second generation of a commercial latex agglutination test for the detection of rotavirus antigens in fecal samples.

Authors:  Poornima Dusetty; F Raúl Velázquez; Ana Lorena Gutiérrez-Escolano; Juan E Ludert
Journal:  J Clin Virol       Date:  2013-02-09       Impact factor: 3.168

10.  Photographed rapid HIV test results pilot novel quality assessment and training schemes.

Authors:  Yu-Ho C Chiu; Joanna Ong; Sandy Walker; July Kumalawati; Tintin Gartinah; Dale A McPhee; Elizabeth M Dax
Journal:  PLoS One       Date:  2011-03-31       Impact factor: 3.240

View more
  1 in total

1.  A pilot study to assess the performance of a rapid ultrasound particle agglutination method for the detection of HIV antibodies.

Authors:  Simon Bystryak; Rajiv P Bandwar; Natalya Ossina
Journal:  J Immunoassay Immunochem       Date:  2021-10-26
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.