Literature DB >> 25758361

Glycosaminoglycan chemical exchange saturation transfer of lumbar intervertebral discs in patients with spondyloarthritis.

Christoph Schleich1, Anja Müller-Lutz1, Felix Matuschke1, Philipp Sewerin2, Ruben Sengewein2, Benjamin Schmitt3, Benedikt Ostendorf2, Hans-Jörg Wittsack1, Karolin Stanke1, Gerald Antoch1, Falk Miese1.   

Abstract

PURPOSE: To assess glycosaminoglycan (GAG) content of lumbar intervertebral discs (IVD) in patients with spondyloarthritis (SpA) using glycosaminoglycan chemical exchange saturation transfer (gagCEST).
MATERIALS AND METHODS: Ninety lumbar intervertebral discs of nine patients with SpA and nine age-matched healthy controls (eight patients with ankylosing spondylitis; one patient with spondylitis related to inflammatory bowel disease; mean age: 44.1 ± 14.0 years; range: 27-72 years) were examined with a 3T magnetic resonance imaging (MRI) scanner in this prospective study. The MRI protocol included standard morphological, sagittal T2 -weighted (T2 w) images to assess Pfirrmann score of the five lumbar IVDs (L1 to S1) and biochemical imaging with gagCEST to calculate a region of interest analysis of nucleus pulposus (NP) and annulus fibrosus (AF). Prior to statistical testing of gagCEST effects (MTRasym values in percent) in patients and controls, IVDs were classified according to the Pfirrmann score.
RESULTS: Significantly lower gagCEST values of NP and AF were found in SpA patients compared with healthy volunteers (NP: 1.41% ± 0.41%, P = 0.001; 95% confidence interval, CI [0.600%-2.226%]; AF: 1.19% ± 0.32%, P < 0.001; CI [0.560%-1.822%]) by comparing the differences of the means. Pooled nondegenerative IVDs (Pfirrmann 1 and 2) had significantly lower gagCEST effects in patients suffering from SpA compared with healthy controls in NP (P < 0.001; CI [1.176%-2.337%]) and AF (P < 0.001; CI [0.858%-1.779%]). No significant difference of MTRasym values was found in degenerative IVDs between patients and controls in NP (P = 0.204; CI [-0.504%-2.170%]).
CONCLUSION: GagCEST analysis of morphologically nondegenerative IVDs (Pfirrmann score 1 and 2) in T2 w images demonstrated significantly lower GAG values in patients with spondyloarthritis in NP and AF, possibly representing a depletion of GAG in spondyloarthritis in the absence of morphologic degeneration.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  glycosaminoglycan chemical exchange saturation transfer; lumbar intervertebral disc; magnetic resonance imaging; magnetization transfer asymmetry ratio; spondyloarthritis

Mesh:

Substances:

Year:  2015        PMID: 25758361     DOI: 10.1002/jmri.24877

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  12 in total

Review 1.  [MRI diagnostics in inflammatory joint and spinal diseases: protocols and special sequences: when and for what?]

Authors:  P Sewerin; B Ostendorf; C Schleich
Journal:  Z Rheumatol       Date:  2018-08       Impact factor: 1.372

2.  RNA Sequencing Reveals a Role of TonEBP Transcription Factor in Regulation of Pro-inflammatory Genes in Response to Hyperosmolarity in Healthy Nucleus Pulposus Cells: A HOMEOSTATIC RESPONSE?

Authors:  Zariel I Johnson; Irving M Shapiro; Makarand V Risbud
Journal:  J Biol Chem       Date:  2016-11-08       Impact factor: 5.157

3.  Comparison of B0 versus B0 and B1 field inhomogeneity correction for glycosaminoglycan chemical exchange saturation transfer imaging.

Authors:  Anja Müller-Lutz; Alexandra Ljimani; Julia Stabinska; Moritz Zaiss; Johannes Boos; Hans-Jörg Wittsack; Christoph Schleich
Journal:  MAGMA       Date:  2018-05-14       Impact factor: 2.310

4.  Biochemical imaging of cervical intervertebral discs with glycosaminoglycan chemical exchange saturation transfer magnetic resonance imaging: feasibility and initial results.

Authors:  Christoph Schleich; Anja Müller-Lutz; Lisa Zimmermann; Johannes Boos; Benjamin Schmitt; Hans-Jörg Wittsack; Gerald Antoch; Falk Miese
Journal:  Skeletal Radiol       Date:  2015-09-16       Impact factor: 2.199

Review 5.  Chemical exchange saturation transfer magnetic resonance imaging and its main and potential applications in pre-clinical and clinical studies.

Authors:  Weiqiang Dou; Chien-Yuan Eddy Lin; Hongyuan Ding; Yong Shen; Carol Dou; Long Qian; Baohong Wen; Bing Wu
Journal:  Quant Imaging Med Surg       Date:  2019-10

Review 6.  Clinical applications of chemical exchange saturation transfer (CEST) MRI.

Authors:  Kyle M Jones; Alyssa C Pollard; Mark D Pagel
Journal:  J Magn Reson Imaging       Date:  2017-08-09       Impact factor: 4.813

7.  Three-dimensional gait quantitative analysis in postoperative rehabilitation of lumbar degenerative diseases: a self-controlled before-after study.

Authors:  Chao Zhou; Haipeng Xia; Jun Yin; Yanping Zheng
Journal:  Am J Transl Res       Date:  2021-06-15       Impact factor: 4.060

8.  Assessment of glycosaminoglycan content in intervertebral discs of patients with leg length discrepancy: A pilot study.

Authors:  David Latz; Miriam Frenken; Erik Schiffner; Maxime Knautz; Wolfgang Alois Quante; Joachim Windolf; Jan Peter Grassmann; Pascal Jungbluth; Christoph Schleich
Journal:  J Orthop       Date:  2019-04-08

9.  MRI-biochemical follow up measurements of lumbar intervertebral disc in patients with leg length discrepancy: Is it possible to alter cartilage damage with conservative therapy?

Authors:  Miriam Frenken; David Latz; Erik Schiffner; Wolfgang Alois Quante; Maxime Knautz; Daniel Benjamin Abrar; Benedikt Schaarschmidt; Christoph Schleich
Journal:  J Orthop       Date:  2019-06-04

10.  A Histopathological Scheme for the Quantitative Scoring of Intervertebral Disc Degeneration and the Therapeutic Utility of Adult Mesenchymal Stem Cells for Intervertebral Disc Regeneration.

Authors:  Cindy C Shu; Margaret M Smith; Susan M Smith; Andrew J Dart; Christopher B Little; James Melrose
Journal:  Int J Mol Sci       Date:  2017-05-12       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.