Performance of an active inspired hypoxic guard.

Idris E Ghijselings1, Sofie De Cooman2, Rik Carette1, Philip J Peyton3, Andre M De Wolf4, Jan F A Hendrickx5.   

Abstract

Current hypoxic guards systems fail to maintain the inspired O2 concentration (FIO2) ≥ 21 % across the entire fresh gas flow (FGF) range when a second carrier gas is used (N2O or air). We examined the performance of the Maquet O2 Guard(®), a smart hypoxic guard that increases O2 delivery if an inspired hypoxic mixture is formed. After obtaining IRB approval and informed consent, 12 ASA I-II patients were enrolled. During anesthesia with sevoflurane in O2/air, the O2 Guard(®) was tested by administering O2/air at the following delivered hypoxic guard limits [expressed as (total FGF in L min(-1); FDO2 in %)] for 4 min each: [0.3;67], [0.4;50], [0.6;34], [0.8;25], [1.0;21], [1.2;21], [1.5;21], [2;21], [3;21], and [5;21]. The following data were collected: (1) time from FIO2 = 30 to 20 %; (2) time from FIO2 = 20 % to O2 Guard(®) activation; (3) time from O2 Guard(®) activation to FIO2 = 25 %; (4) FGF and FDO2 used by the O2 Guard. If SpO2 was <90 % for 10 s or longer at any time, the patient was excluded. Three patients were excluded for low SpO2. The incidence of FIO2 < 21 % was 100 % within the 1-2 L min(-1) FGF range. The O2 Guard(®) was activated within 20 s after FIO2 became 20 %, except in one patient where FIO2 oscillated between 20 and 21 %. FDO2 was increased to 60 % and FGF to 1 L min(-1) (the latter only if it was lower than 1 L min(-1) prior to activation of the O2 Guard). FIO2 increased to 25 % within 55 s after O2 Guard activation in all patients. The O2 Guard(®), an active inspired hypoxic guard, rapidly reverses and limits the duration of inspired hypoxic episodes when the delivered hypoxic guard fails to do so.

Entities:  

Keywords:  Hypoxia; Hypoxic guard system; Hypoxic mixtures; Machine standards

Mesh:

Substances:

Year:  2015        PMID: 25757405     DOI: 10.1007/s10877-015-9684-9

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  1 in total

1.  Hypoxic guard systems do not prevent rapid hypoxic inspired mixture formation.

Authors:  Sofie De Cooman; Caroline Schollaert; Jan F A Hendrickx; Philip J Peyton; Tom Van Zundert; Andre M De Wolf
Journal:  J Clin Monit Comput       Date:  2014-10-01       Impact factor: 2.502

  1 in total
  4 in total

1.  Letter to the Editor.

Authors:  Stellan Eriksson; Sixten Bredbacka
Journal:  J Clin Monit Comput       Date:  2015-06-16       Impact factor: 2.502

2.  More on the danger of inhaling air at reduced fresh gas flows: a self-experiment.

Authors:  Stellan Eriksson; Bredbacka Sixten
Journal:  J Clin Monit Comput       Date:  2015-06-23       Impact factor: 2.502

Review 3.  Journal of clinical monitoring and computing 2016 end of year summary: anesthesia.

Authors:  Jan F A Hendrickx; Andre M De Wolf
Journal:  J Clin Monit Comput       Date:  2017-01-07       Impact factor: 2.502

4.  FLOW-i ventilator performance in the presence of a circle system leak.

Authors:  Umberto Lucangelo; Miloš Ajčević; Agostino Accardo; Massimo Borelli; Alberto Peratoner; Lucia Comuzzi; Walter A Zin
Journal:  J Clin Monit Comput       Date:  2016-04-09       Impact factor: 2.502

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.