PURPOSE: Gingival management is a substantive procedure in fixed dental prosthesis treatment. Various new retraction cord systems are available and used. This study aimed to compare the efficacy of a new retraction cord (Stay-Put, Coltene Whaledent AG) and a conventional retraction cord (Ultrapak, Ultradent Products Inc., South Jordan, Utah) on lateral gingival displacement in continuation with the treatment protocol of the subjects fixed dental prosthesis for various partial edentulous conditions requiring fixed dental prosthesis.
METHOD: Thirty subjects were selected who needed bilateral fixed dental restoration. In selected subjects both gingival retraction cords were placed bilaterally buccolingually by simple randomization method. After removing the cords, impressions were made and undamaged definitive casts were retrieved. The abutment teeth were sectioned buccolingually at the buccal ridge followed by decimal measurement of the width (in millimeter) of the retracted gingival sulcus, under a traveling microscope.
RESULTS: Data was analyzed using SPSS version. Paired "t" test was used to compare the difference between the displaced gingival width in two retraction group (p > 0.05).
CONCLUSION: Although mean gingival retraction in Stay-Put system (0.528 ± 0.12 mm) was higher as compared to that in Ultrapak (0.487 ± 0.10 mm), the difference between the two systems (0.041 ± 0.11) was not significant statistically (p = 0.057).

Entities:  

Keywords:  Gingival retraction; Lateral displacement; Stay-Put; Travelling microscope; Ultrapak

Year:  2013        PMID: 25737887      PMCID: PMC3942248          DOI: 10.1016/j.jobcr.2013.05.006

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  13 in total

Review 1.  Final impressions: a review of material properties and description of a current technique.

Authors:  Nikolaos Perakis; Urs C Belser; Pascal Magne
Journal:  Int J Periodontics Restorative Dent       Date:  2004-04       Impact factor: 1.840

Review 2.  Current concepts in gingival displacement.

Authors:  Terry E Donovan; Winston W L Chee
Journal:  Dent Clin North Am       Date:  2004-04

3.  Soft tissue management for difficult cervical restorations.

Authors:  Mark Meraner
Journal:  Gen Dent       Date:  2006 Mar-Apr

4.  Quality of impressions using hydrophilic polyvinyl siloxane in a clinical study of 249 patients.

Authors:  Ulrike Stephanie Beier; Ingrid Grunert; Siegfried Kulmer; Herbert Dumfahrt
Journal:  Int J Prosthodont       Date:  2007 May-Jun       Impact factor: 1.681

Review 5.  Gingival retraction techniques for implants versus teeth: current status.

Authors:  Vincent Bennani; Donald Schwass; Nicholas Chandler
Journal:  J Am Dent Assoc       Date:  2008-10       Impact factor: 3.634

6.  Comparison of gingival resection with electrosurgery and periodontal knives--a biometric and histologic study.

Authors:  I Glickman; L R Imber
Journal:  J Periodontol       Date:  1970-03       Impact factor: 6.993

7.  Reactions to marginal periodontal tissues to restorative procedures.

Authors:  H Löe
Journal:  Int Dent J       Date:  1968-12       Impact factor: 2.512

8.  The effect of gingival retraction procedures on periodontal indices and crevicular fluid cytokine levels: a pilot study.

Authors:  Jian Feng; Hoda Aboyoussef; Saul Weiner; Surendra Singh; John Jandinski
Journal:  J Prosthodont       Date:  2006 Mar-Apr       Impact factor: 2.752

9.  Effect of retraction procedures on the periodontium in humans.

Authors:  J Ruel; P J Schuessler; K Malament; D Mori
Journal:  J Prosthet Dent       Date:  1980-11       Impact factor: 3.426

10.  The effect of sulcular width on the linear accuracy of impression materials in the presence of an undercut.

Authors:  Haim Baharav; Irit Kupershmidt; Ben-Zion Laufer; Harold S Cardash
Journal:  Int J Prosthodont       Date:  2004 Sep-Oct       Impact factor: 1.681

View more
  4 in total

1.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

2.  Comparative Evaluation of the Amount of Gingival Displacement Using Three Recent Gingival Retraction Systems - In vivo Study.

Authors:  Siddique Mohammed Qureshi; Nayana Shriram Anasane; Dilip Kakade
Journal:  Contemp Clin Dent       Date:  2020-07-13

3.  Comparative Study on the Efficacy of Gingival Retraction using Polyvinyl Acetate Strips and Conventional Retraction Cord - An in Vivo Study.

Authors:  M Shivasakthy; Syed Asharaf Ali
Journal:  J Clin Diagn Res       Date:  2013-09-16

4.  A Comparative Evaluation of Efficacy of Gingival Retraction Using Polyvinyl Siloxane Foam Retraction System, Vinyl Polysiloxane Paste Retraction System, and Copper Wire Reinforced Retraction Cord in Endodontically Treated Teeth: An in vivo Study.

Authors:  Sonal Mehta; Hemali Virani; Sarfaraz Memon; Narendra Nirmal
Journal:  Contemp Clin Dent       Date:  2019 Jul-Sep
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.