Literature DB >> 25723651

Characteristic myocardial strain identified in hypertrophic cardiomyopathy subjects with preserved left ventricular ejection fraction using a novel multi-layer transthoracic echocardiography technique.

Koya Ozawa1, Nobusada Funabashi2, Hiroyuki Takaoka1, Tomoko Kamata3, Akiyo Kanaeda3, Mariko Saito3, Fumio Nomura3, Yoshio Kobayashi1.   

Abstract

PURPOSE: In order to evaluate compensatory mechanisms in hypertrophic-cardiomyopathy (HCM) subjects with preserved left-ventricular (LV) ejection-fraction (EF), we measured myocardial percentage endocardial strain dependency, as represented by 2D LV global longitudinal (GLS) and circumferential-strain (GCS), using a novel, multi-layer, speckle-tracking transthoracic-echocardiography (TTE) technique.
METHODS: A total of 60 subjects (40 HCM with preserved LV EF (30 male; 62 ± 15 years, all LV EF>50%)) and 20 controls (10 male; 59 ± 10 years) underwent TTE (Vivid-E9). Quantitative strain-measurements of: endocardial, all and epicardial layers were performed at each-site. We defined percentage endocardial strain dependency as the ratio of endocardial strain to epicardial strain.
RESULTS: Absolute GLS values at all views in all, endocardial and epicardial myocardial layers were significantly smaller in HCM subjects than in controls (all P<0.001). There were no significant differences between both-groups in absolute GCS values in the endocardial layers, at the mitral valve and papillary muscle levels. Percentage endocardial GCS dependency at all levels were greater in HCM subjects than in controls (all P<0.01). In HCM subjects, percentage endocardial GCS dependency at the mitral valve and papillary muscle levels revealed significant, moderate, negative correlations with LV end-diastolic and systolic dimensions (correlation coefficients -0.505, -0.451 (mitral valve level) and -0.533, -0.591 (papillary muscle level), respectively).
CONCLUSIONS: In HCM subjects with preserved LV EF, 2D LV GLS was lower than in controls, but endocardial GCS was maintained in compensation for reduction in endocardial GLS; thus percentage endocardial GCS dependency may increase, and the larger the LV size, the smaller this compensatory effect.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Hypertrophic cardiomyopathy; Myocardial strain; Novel multi-layer technique; Preserved left ventricular ejection fraction; Speckle tracking transthoracic echocardiography technique

Mesh:

Year:  2015        PMID: 25723651     DOI: 10.1016/j.ijcard.2015.01.070

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  17 in total

1.  Quantitative evaluation of longitudinal strain in layer-specific myocardium in patients with preeclampsia.

Authors:  Juan Cong; Yong Lee; Xiuxiu Fu; Zhibin Wang; Wugang Wang; Junfang Lee
Journal:  Int J Cardiovasc Imaging       Date:  2017-08-03       Impact factor: 2.357

2.  2D speckle-tracking TTE-based quantitative classification of left ventricular myocardium in patients with hypertrophic cardiomyopathy by the presence or the absence of fibrosis and/or hypertrophy.

Authors:  Nobusada Funabashi; Hiroyuki Takaoka; Koya Ozawa; Masae Uehara; Issei Komuro; Yoshio Kobayashi
Journal:  Heart Vessels       Date:  2018-03-22       Impact factor: 2.037

3.  Prognostic value of regional strain by cardiovascular magnetic resonance feature tracking in hypertrophic cardiomyopathy.

Authors:  Xiaorong Chen; Jiangfeng Pan; Jiner Shu; Xiaoru Zhang; Limei Ye; Lin Chen; Yi Hu; Risheng Yu
Journal:  Quant Imaging Med Surg       Date:  2022-01

4.  Characterization of hypertrophic cardiomyopathy according to global, regional, and multi-layer longitudinal strain analysis, and prediction of sudden cardiac death.

Authors:  Marie-Philippe Vergé; Hubert Cochet; Amélie Reynaud; Lucas Morlon; Jérôme Peyrou; Cécile Vincent; Caroline Rooryck; Philippe Ritter; Stéphane Lafitte; Patricia Réant
Journal:  Int J Cardiovasc Imaging       Date:  2018-02-27       Impact factor: 2.357

Review 5.  Recent advances in echocardiography: strain and strain rate imaging.

Authors:  Oana Mirea; Jurgen Duchenne; Jens-Uwe Voigt
Journal:  F1000Res       Date:  2016-04-29

6.  Normal range of myocardial layer-specific strain using two-dimensional speckle tracking echocardiography.

Authors:  Yasufumi Nagata; Victor Chien-Chia Wu; Yutaka Otsuji; Masaaki Takeuchi
Journal:  PLoS One       Date:  2017-06-29       Impact factor: 3.240

7.  Strain Imaging Echocardiography: What Imaging Cardiologists Should Know.

Authors:  Angel Lopez-Candales; Dagmar F Hernandez-Suarez
Journal:  Curr Cardiol Rev       Date:  2017

8.  Left and Right Myocardial Functionality Assessed by Two-Dimensional Speckle-Tracking Echocardiography in Cats with Restrictive Cardiomyopathy.

Authors:  Ryohei Suzuki; Yunosuke Yuchi; Haruka Kanno; Takahiro Teshima; Hirotaka Matsumoto; Hidekazu Koyama
Journal:  Animals (Basel)       Date:  2021-05-28       Impact factor: 2.752

9.  Global longitudinal strain: a useful everyday measurement?

Authors:  A King; J Thambyrajah; E Leng; M J Stewart
Journal:  Echo Res Pract       Date:  2016-09-14

10.  The systolic paradox in hypertrophic cardiomyopathy.

Authors:  Trine F Haland; Nina E Hasselberg; Vibeke Marie Almaas; Lars A Dejgaard; Jørg Saberniak; Ida S Leren; Knut Erik Berge; Kristina H Haugaa; Thor Edvardsen
Journal:  Open Heart       Date:  2017-05-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.