Literature DB >> 18196407

Measurement of hip range of flexion-extension and straight-leg raising.

R A Elson1, G R Aspinall.   

Abstract

We believe there is a degree of inaccuracy in the usual methods of evaluation of range at the hip in the sagittal plane, ie, flexion-extension. We describe a simple method of measuring more accurately the range of hip flexion-extension, presuming such ranges of motion should relate to the anatomic position of the pelvis. We used this technique for the measurement of flexion and extension of the left hip in a cohort of 200 healthy individuals; we found a wide range of both flexion (80 degrees-140 degrees ) and extension (5 degrees-40 degrees ). Especially with respect to extension, we believe more conventional methods underestimate the ranges of motion. As a corollary to this study, we suggest some reappraisal of the straight-leg-raising test by which pain from nerve root tension can be distinguished from a source of pain arising locally in intervertebral joints for mechanical reasons or from the hip itself. We recommend the method described as being useful in the consulting office.

Entities:  

Mesh:

Year:  2008        PMID: 18196407      PMCID: PMC2505147          DOI: 10.1007/s11999-007-0073-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  1 in total

1.  The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment.

Authors:  A M DiGioia; B Jaramaz; M Blackwell; D A Simon; F Morgan; J E Moody; C Nikou; B D Colgan; C A Aston; R S Labarca; E Kischell; T Kanade
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

  1 in total
  6 in total

1.  Combining femoral and acetabular parameters in femoroacetabular impingement: the omega surface.

Authors:  Heinse Bouma; Tom Hogervorst; Emanuel Audenaert; Paulien van Kampen
Journal:  Med Biol Eng Comput       Date:  2015-10-07       Impact factor: 2.602

2.  Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test.

Authors:  David A Krause; Michael S Boyd; Allison N Hager; Eric C Smoyer; Anthony T Thompson; John H Hollman
Journal:  Int J Sports Phys Ther       Date:  2015-02

3.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

4.  Radiological Assessment of the Sacrofemoral Angle: A Novel Method to Measure the Range of Hip Joint Flexion.

Authors:  Xian-Zhao Wei; Xi-Ming Xu; Fei Wang; Ming Li; Zi-Min Wang
Journal:  Chin Med J (Engl)       Date:  2015-09-05       Impact factor: 2.628

5. 

Authors:  Fabiana C M S Dutra; Marisa C Mancini; Jorge A Neves; Renata N Kirkwood; Rosana F Sampaio
Journal:  Braz J Phys Ther       Date:  2016-06-16       Impact factor: 3.377

6.  Clinical and Radiological Outcomes of Revision Total Hip Arthroplasty for Patients with Prior Hartofilakidis Type C Hip Dysplasia.

Authors:  Shengjie Guo; Hao Tang; Zhuyi Ma; Yong Huang; Yixin Zhou
Journal:  Orthop Surg       Date:  2022-09-03       Impact factor: 2.279

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.