Literature DB >> 21983191

Validation of a photography-based goniometry method for measuring joint range of motion.

Davide Blonna1, Peter C Zarkadas, James S Fitzsimmons, Shawn W O'Driscoll.   

Abstract

BACKGROUND: A critical component of evaluating the outcomes after surgery to restore lost elbow motion is the range of motion (ROM) of the elbow. This study examined if digital photography-based goniometry is as accurate and reliable as clinical goniometry for measuring elbow ROM.
MATERIALS AND METHODS: Instrument validity and reliability for photography-based goniometry were evaluated for a consecutive series of 50 elbow contractures by 4 observers with different levels of elbow experience. Goniometric ROM measurements were taken with the elbows in full extension and full flexion directly in the clinic (once) and from digital photographs (twice in a blinded random manner).
RESULTS: Instrument validity for photography-based goniometry was extremely high (intraclass correlation coefficient: extension = 0.98, flexion = 0.96). For extension and flexion measurements by the expert surgeon, systematic error was negligible (0° and 1°, respectively). Limits of agreement were 7° (95% confidence interval [CI], 5° to 9°) and -7° (95% CI, -5° to -9°) for extension and 8° (95% CI, 6° to 10°) and -7° (95% CI, -5° to -9°) for flexion. Interobserver reliability for photography-based goniometry was better than that for clinical goniometry. The least experienced observer's photographic goniometry measurements were closer to the reference measurements than the clinical goniometry measurements.
CONCLUSIONS: Photography-based goniometry is accurate and reliable for measuring elbow ROM. The photography-based method relied less on observer expertise than clinical goniometry. This validates an objective measure of patient outcome without requiring doctor-patient contact at a tertiary care center, where most contracture surgeries are done.
Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21983191     DOI: 10.1016/j.jse.2011.06.018

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  23 in total

1.  Accuracy and inter-observer reliability of visual estimation compared to clinical goniometry of the elbow.

Authors:  Davide Blonna; Peter C Zarkadas; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-17       Impact factor: 4.342

2.  At Home Photography-Based Method for Measuring Wrist Range of Motion.

Authors:  Samir K Trehan; Schneider K Rancy; Parker H Johnsen; Howard J Hillstrom; Steve K Lee; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2017-03-14

3.  Comparative analysis of photograph-based clinical goniometry to standard techniques.

Authors:  Jared A Crasto; Arash J Sayari; Robert R-L Gray; Morad Askari
Journal:  Hand (N Y)       Date:  2015-06

4.  Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test.

Authors:  David A Krause; Michael S Boyd; Allison N Hager; Eric C Smoyer; Anthony T Thompson; John H Hollman
Journal:  Int J Sports Phys Ther       Date:  2015-02

5.  Posteriorly Displaced Radial Head Fractures May Represent the Footprint of an Elbow Dislocation or Subluxation as a Variant of Modified Mason Type 4.

Authors:  Monica M Shoji; Magdalena Hartwich Garcen; Alberto A Fernandez Dell'Oca; Jesse B Jupiter
Journal:  Arch Bone Jt Surg       Date:  2022-06

6.  Smartphone "Selfies"-A reliable and accurate tool for measuring elbow range of motion.

Authors:  Maegan N Shields; Anthony M Vaichinger; Shawn W O'Driscoll
Journal:  Shoulder Elbow       Date:  2019-09-03

7.  Normative values and affecting factors for the elbow range of motion.

Authors:  Elisa L Zwerus; Nienke W Willigenburg; Vanessa A Scholtes; Matthijs P Somford; Denise Eygendaal; Michel Pj van den Bekerom
Journal:  Shoulder Elbow       Date:  2017-09-11

8.  Does the triceps-on approach affect alignment in total elbow arthroplasty? A cadaveric study.

Authors:  Andrew King; Jonathan P Evans; Simon J Booker; James Cs Beazley; Robin Js Jones; William Jc Thomas; Christopher Smith
Journal:  Shoulder Elbow       Date:  2018-05-25

Review 9.  The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature.

Authors:  Suzanne F van Rijn; Elisa L Zwerus; Koen Lm Koenraadt; Wilco Ch Jacobs; Michel Pj van den Bekerom; Denise Eygendaal
Journal:  Shoulder Elbow       Date:  2018-06-03

10.  The Elbow Physical Examination for Telemedicine Encounters.

Authors:  Cort D Lawton; Stephanie Swensen-Buza; Jakob F Awender; Sridhar Pinnamaneni; Joseph D Lamplot; Warren K Young; Scott A Rodeo; Danyal H Nawabi; Samuel A Taylor; Joshua S Dines
Journal:  HSS J       Date:  2021-02-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.