Literature DB >> 25706578

CSI-EPT: A Contrast Source Inversion Approach for Improved MRI-Based Electric Properties Tomography.

Edmond Balidemaj, Cornelis A T van den Berg, Johan Trinks, Astrid L H M W van Lier, Aart J Nederveen, Lukas J A Stalpers, Hans Crezee, Rob F Remis.   

Abstract

Electric properties tomography (EPT) is an imaging modality to reconstruct the electric conductivity and permittivity inside the human body based on B1(+) maps acquired by a magnetic resonance imaging (MRI) system. Current implementations of EPT are based on the local Maxwell equations and assume piecewise constant media. The accuracy of the reconstructed maps may therefore be sensitive to noise and reconstruction errors occur near tissue boundaries. In this paper, we introduce a multiplicative regularized CSI-EPT method (contrast source inversion-electric properties tomography) where the electric tissue properties are retrieved in an iterative fashion based on a contrast source inversion approach. The method takes the integral representations for the electromagnetic field as a starting point and the tissue parameters are obtained by iteratively minimizing an objective function which measures the discrepancy between measured and modeled data and the discrepancy in satisfying a consistency equation known as the object equation. Furthermore, the objective function consists of a multiplicative Total Variation factor for noise suppression during the reconstruction process. Finally, the presented implementation is able to simultaneously include more than one B1(+) data set acquired by complementary RF excitation settings. We have performed in vivo simulations using a female pelvis model to compute the B1(+) fields. Three different RF excitation settings were used to acquire complementary B1(+) fields for an improved overall reconstruction. Numerical results illustrate the improved reconstruction near tissue boundaries and the ability of CSI-EPT to reconstruct small tissue structures.

Entities:  

Mesh:

Year:  2015        PMID: 25706578     DOI: 10.1109/TMI.2015.2404944

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  15 in total

1.  3-D Microwave Tomography Using the Soft Prior Regularization Technique: Evaluation in Anatomically Realistic MRI-Derived Numerical Breast Phantoms.

Authors:  Amir H Golnabi; Paul M Meaney; Shireen D Geimer; Keith D Paulsen
Journal:  IEEE Trans Biomed Eng       Date:  2019-01-10       Impact factor: 4.538

2.  Mapping electrical properties heterogeneity of tumor using boundary informed electrical properties tomography (BIEPT) at 7T.

Authors:  Yicun Wang; Qi Shao; Pierre-Francois Van de Moortele; Emilian Racila; Jiaen Liu; John Bischof; Bin He
Journal:  Magn Reson Med       Date:  2018-09-19       Impact factor: 4.668

3.  Brain Tissue Conductivity Measurements with MR-Electrical Properties Tomography: An In Vivo Study.

Authors:  Stefano Mandija; Petar I Petrov; Jord J T Vink; Sebastian F W Neggers; Cornelis A T van den Berg
Journal:  Brain Topogr       Date:  2020-12-08       Impact factor: 3.020

4.  In vivo imaging of electrical properties of an animal tumor model with an 8-channel transceiver array at 7 T using electrical properties tomography.

Authors:  Jiaen Liu; Qi Shao; Yicun Wang; Gregor Adriany; John Bischof; Pierre-Francois Van de Moortele; Bin He
Journal:  Magn Reson Med       Date:  2017-01-23       Impact factor: 4.668

5.  CONtrast Conformed Electrical Properties Tomography (CONCEPT) Based on Multi- Channel Transmission and Alternating Direction Method of Multipliers.

Authors:  Yicun Wang; Pierre-Francois Van De Moortele; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2018-08-13       Impact factor: 10.048

6.  Magnetic-Resonance-Based Electrical Property Mapping Using Global Maxwell Tomography With an 8-Channel Head Coil at 7 Tesla: A Simulation Study.

Authors:  Ilias I Giannakopoulos; Jose E C Serralles; Luca Daniel; Daniel K Sodickson; Athanasios G Polimeridis; Jacob K White; Riccardo Lattanzi
Journal:  IEEE Trans Biomed Eng       Date:  2020-12-21       Impact factor: 4.538

7.  B1-based SAR reconstruction using contrast source inversion-electric properties tomography (CSI-EPT).

Authors:  Edmond Balidemaj; Cornelis A T van den Berg; Astrid L H M W van Lier; Aart J Nederveen; Lukas J A Stalpers; Hans Crezee; Rob F Remis
Journal:  Med Biol Eng Comput       Date:  2016-04-23       Impact factor: 2.602

8.  Electrical Properties Tomography Based on $B_{{1}}$ Maps in MRI: Principles, Applications, and Challenges.

Authors:  Jiaen Liu; Yicun Wang; Ulrich Katscher; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2017-08-21       Impact factor: 4.538

9.  Accuracy and precision of electrical permittivity mapping at 3T: the impact of three B 1 + mapping techniques.

Authors:  Soraya Gavazzi; Cornelis A T van den Berg; Alessandro Sbrizzi; H Petra Kok; Lukas J A Stalpers; Jan J W Lagendijk; Hans Crezee; Astrid L H M W van Lier
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

10.  Opening a new window on MR-based Electrical Properties Tomography with deep learning.

Authors:  Stefano Mandija; Ettore F Meliadò; Niek R F Huttinga; Peter R Luijten; Cornelis A T van den Berg
Journal:  Sci Rep       Date:  2019-06-20       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.