Literature DB >> 15955850

Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging.

Theano Papavassiliu1, Harald P Kühl, Meike Schröder, Tim Süselbeck, Olga Bondarenko, Christoph K Böhm, Aernout Beek, Mark M B Hofman, Albert C van Rossum.   

Abstract

PURPOSE: To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP).
MATERIALS AND METHODS: The study was approved by the local ethics committee, and each subject gave informed consent before participating. Twenty healthy subjects and 20 consecutive patients underwent 1.5-T cardiovascular MR imaging. Seven to 12 short-axis views encompassing the entire LV were acquired by using true FISP. Endocardial and epicardial contours were traced manually. The data sets in each patient were analyzed twice: with inclusion of endocardial trabeculae in the LV cavity volume and with exclusion of endocardial trabeculae from the cavity volume. On the basis of these two contour sets, the end-diastolic (ED) and end-systolic (ES) LV volumes, ejection fraction (EF), and LV mass were calculated. Additionally, interobserver and interexamination reproducibility was assessed by using Bland-Altman analysis.
RESULTS: Compared with exclusion of trabeculae, inclusion of trabeculae in the LV cavity volume resulted in significantly larger ED and ES LV volumes (mean differences, 21 mL +/- 11 [standard deviation] and 19 mL +/- 33, respectively; P < .001) and lower EFs (mean difference, -2% +/- 2; P < .001). The calculated LV mass was significantly smaller with inclusion than with exclusion of trabeculae (mean difference, -21 g +/- 12; P < .001). All interobserver and interexamination limits of agreement based on inclusion of trabeculae, except those for EF measurements, were superior to those based on exclusion of trabeculae. At measurement reproducibility comparisons, differences in interobserver ED LV volume and LV mass and interexamination LV mass were statistically significant, favoring the inclusion of trabeculae in the LV cavity volume.
CONCLUSION: Trabeculae significantly affect quantifications of LV volume and mass. The superior reproducibility of LV measurements with the inclusion of endocardial trabeculae in the cavity volume favors this tracing algorithm for clinical use. Copyright RSNA, 2005

Entities:  

Mesh:

Year:  2005        PMID: 15955850     DOI: 10.1148/radiol.2353040601

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  59 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  Assessment of global left ventricular functional parameters: analysis of every second short-axis Magnetic Resonance Imaging slices is as accurate as analysis of consecutive slices.

Authors:  Daniel D Lubbers; Tineke P Willems; Pieter A van der Vleuten; Jelle Overbosch; Marco J W Götte; Dirk J van Veldhuisen; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2007-06-28       Impact factor: 2.357

3.  Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes.

Authors:  J A van der Heide; H F J Mannaerts; L Yang; G T Sieswerda; C A Visser; O Kamp
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

4.  The importance of trabecular hypertrophy in right ventricular adaptation to chronic pressure overload.

Authors:  Mariëlle C van de Veerdonk; Sophie A Dusoswa; J Tim Marcus; Harm-Jan Bogaard; Onno Spruijt; Taco Kind; Nico Westerhof; Anton Vonk-Noordegraaf
Journal:  Int J Cardiovasc Imaging       Date:  2013-12-04       Impact factor: 2.357

5.  Automatic functional analysis of left ventricle in cardiac cine MRI.

Authors:  Ying-Li Lu; Kim A Connelly; Alexander J Dick; Graham A Wright; Perry E Radau
Journal:  Quant Imaging Med Surg       Date:  2013-08

6.  Impact of the papillary muscles on cardiac magnetic resonance image analysis of important left ventricular parameters in hypertrophic cardiomyopathy.

Authors:  D H F Gommans; J Bakker; G E Cramer; F W A Verheugt; M A Brouwer; M J M Kofflard
Journal:  Neth Heart J       Date:  2016-05       Impact factor: 2.380

7.  Mitral regurgitation quantification by cardiovascular magnetic resonance: a comparison of indirect quantification methods.

Authors:  Christian L Polte; Odd Bech-Hanssen; Åse A Johnsson; Sinsia A Gao; Kerstin M Lagerstrand
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-23       Impact factor: 2.357

8.  Influence of CT-based attenuation correction in assessment of left and right ventricular functions with count-based gated blood-pool SPECT.

Authors:  Louis Sibille; Fayçal Ben Bouallegue; Aurélie Bourdon; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2011-06-07       Impact factor: 5.952

9.  Semi-automatic quantification of 4D left ventricular blood flow.

Authors:  Jonatan Eriksson; Carl Johan Carlhäll; Petter Dyverfeldt; Jan Engvall; Ann F Bolger; Tino Ebbers
Journal:  J Cardiovasc Magn Reson       Date:  2010-02-12       Impact factor: 5.364

10.  Normal right- and left ventricular volumes and myocardial mass in children measured by steady state free precession cardiovascular magnetic resonance.

Authors:  Emanuela Valsangiacomo Buechel; Thomas Kaiser; Clare Jackson; Achim Schmitz; Christian J Kellenberger
Journal:  J Cardiovasc Magn Reson       Date:  2009-06-21       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.