Literature DB >> 25697720

Nonenhanced peripheral MR-angiography (MRA) at 3 Tesla: evaluation of quiescent-interval single-shot MRA in patients undergoing digital subtraction angiography.

Moritz Wagner1, Gesine Knobloch, Martin Gielen, Marie-Teres Lauff, Valentina Romano, Bernd Hamm, Thomas Kröncke.   

Abstract

Quiescent-interval single-shot MRA (QISS-MRA) is a promising nonenhanced imaging technique for assessment of peripheral arterial disease (PAD). Previous studies at 3 Tesla included only very limited numbers of patients for correlation of QISS-MRA with digital subtraction angiography (DSA) as standard of reference (SOR). The aim of this prospective institutional review board-approved study was to compare QISS-MRA at 3 Tesla with DSA in a larger patient group. Our study included 32 consecutive patients who underwent QISS-MRA, contrast-enhanced MRA (CE-MRA), and DSA. Two readers independently performed a per-segment evaluation of QISS-MRA and CE-MRA for image quality and identification of non-significant stenosis (<50%) versus significant stenosis (50-100%). The final dataset included 1,027 vessel segments. Reader 1 and 2 rated image quality as diagnostic in 96.8 and 98.0% of the vessel segments on QISS-MRA and in 99.3 and 98.4% of the vessel segments on CE-MRA, respectively. DSA was available for 922 segments and detected significant stenosis in 133 segments (14.4%). Consensus reading yielded the following diagnostic parameters for QISS-MRA versus CE-MRA: sensitivity: 83.5% (111/133) versus 82.7% (110/133), p = 0.80; specificity: 93.9% (741/789) versus 95.7% (755/789), p = 0.25; and diagnostic accuracy: 92.4% (852/922) versus 93.8% (865/922), p = 0.35. In conclusion, using DSA as SOR, QISS-MRA and CE-MRA at 3 Tesla showed similar diagnostic accuracy in the assessment of PAD. A limitation of QISS-MRA was the lower rate of assessable vessel segments compared to CE-MRA.

Entities:  

Mesh:

Year:  2015        PMID: 25697720     DOI: 10.1007/s10554-015-0612-3

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  28 in total

1.  Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: comparison with contrast-enhanced MRA.

Authors:  J Klasen; D Blondin; P Schmitt; X Bi; R Sansone; H-J Wittsack; P Kröpil; M Quentin; J Kuhlemann; F Miese; C Heiss; M Kelm; G Antoch; R S Lanzman
Journal:  Clin Radiol       Date:  2011-12-03       Impact factor: 2.350

2.  Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA.

Authors:  Stefan Haneder; Ulrike I Attenberger; Philipp Riffel; Thomas Henzler; Stefan O Schoenberg; Henrik J Michaely
Journal:  Eur Radiol       Date:  2011-01-28       Impact factor: 5.315

Review 3.  Nonenhanced MR angiography.

Authors:  Mitsue Miyazaki; Vivian S Lee
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

4.  Peripheral arterial disease in a symptomatic diabetic population: prospective comparison of rapid unenhanced MR angiography (MRA) with contrast-enhanced MRA.

Authors:  Philip A Hodnett; Emily V Ward; Amir H Davarpanah; Timothy G Scanlon; Jeremy D Collins; Christopher B Glielmi; Xiaoming Bi; Ioannis Koktzoglou; Navyash Gupta; James C Carr; Robert R Edelman
Journal:  AJR Am J Roentgenol       Date:  2011-12       Impact factor: 3.959

Review 5.  Lower-extremity peripheral arterial disease among patients with end-stage renal disease.

Authors:  Ann O'Hare; Kirsten Johansen
Journal:  J Am Soc Nephrol       Date:  2001-12       Impact factor: 10.121

6.  Peripheral arterial disease and kidney failure: a frequent association.

Authors:  Salvador Tranche-Iparraguirre; Rafael Marín-Iranzo; Rebeca Fernández-de Sanmamed; Alba Riesgo-García; Eduardo Hevia-Rodríguez; Juan B García-Casas
Journal:  Nefrologia       Date:  2012-01-27       Impact factor: 2.033

7.  ECG-triggered non-contrast-enhanced MR angiography (TRANCE) versus digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease of the lower extremities.

Authors:  Andreas Gutzeit; Reto Sutter; Johannes M Froehlich; Justus E Roos; Thomas Sautter; Erik Schoch; Barbara Giger; Michael Wyss; Nicole Graf; Constantin von Weymarn; Regula Jenelten; Christoph A Binkert; Klaus Hergan
Journal:  Eur Radiol       Date:  2011-05-01       Impact factor: 5.315

8.  High-resolution 3D non-contrast-enhanced, ECG-gated, multi-step MR angiography of the lower extremities: comparison with contrast-enhanced MR angiography.

Authors:  Oliver K Mohrs; Steffen E Petersen; Martin C Heidt; Thomas Schulze; Peter Schmitt; Sabine Bergemann; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2010-08-13       Impact factor: 5.315

9.  High prevalence of peripheral arterial disease in persons with renal insufficiency: results from the National Health and Nutrition Examination Survey 1999-2000.

Authors:  Ann M O'Hare; David V Glidden; Caroline S Fox; Chi-Yuan Hsu
Journal:  Circulation       Date:  2004-01-19       Impact factor: 29.690

10.  Prevalence of and risk factors for peripheral arterial disease in the United States: results from the National Health and Nutrition Examination Survey, 1999-2000.

Authors:  Elizabeth Selvin; Thomas P Erlinger
Journal:  Circulation       Date:  2004-07-19       Impact factor: 29.690

View more
  10 in total

1.  Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA.

Authors:  Gesine Knobloch; Marie-Teres Lauff; Sebastian Hirsch; Carsten Schwenke; Bernd Hamm; Moritz Wagner
Journal:  Eur Radiol       Date:  2016-02-10       Impact factor: 5.315

2.  Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques.

Authors:  Mustafa A Altaha; Jeffrey D Jaskolka; Kongteng Tan; Manuela Rick; Peter Schmitt; Ravi J Menezes; Bernd J Wintersperger
Journal:  Eur Radiol       Date:  2016-06-28       Impact factor: 5.315

Review 3.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

4.  Free-Breathing Fast Low-Angle Shot Quiescent-Interval Slice-Selective Magnetic Resonance Angiography for Improved Detection of Vascular Stenoses in the Pelvis and Abdomen: Technical Development.

Authors:  Akos Varga-Szemes; Emily A Aherne; U Joseph Schoepf; Thomas M Todoran; Ioannis Koktzoglou; Robert R Edelman
Journal:  Invest Radiol       Date:  2019-12       Impact factor: 6.016

Review 5.  Cardiovascular imaging 2015 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2016-05       Impact factor: 2.357

Review 6.  Lower extremity CT angiography in peripheral arterial disease: from the established approach to evolving technical developments.

Authors:  Omar Shwaiki; Basem Rashwan; Matthias A Fink; Levester Kirksey; Sameer Gadani; Karunakaravel Karuppasamy; Claudius Melzig; Dustin Thompson; Giuseppe D'Amico; Fabian Rengier; Sasan Partovi
Journal:  Int J Cardiovasc Imaging       Date:  2021-05-17       Impact factor: 2.357

7.  A meta-analysis of the diagnostic performance of quiescent-interval-single-shot magnetic resonance angiography in peripheral arterial disease.

Authors:  Mansi Verma; Niraj Nirmal Pandey; Vishwajeet Singh; Priya Jagia
Journal:  Eur Radiol       Date:  2021-11-12       Impact factor: 7.034

Review 8.  Imaging of atherosclerosis.

Authors:  Richard A P Takx; Sasan Partovi; Brian B Ghoshhajra
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-04       Impact factor: 2.357

9.  Non-contrast MRI protocol for TAVI guidance: quiescent-interval single-shot angiography in comparison with contrast-enhanced CT.

Authors:  Mathias Pamminger; Gert Klug; Christof Kranewitter; Martin Reindl; Sebastian J Reinstadler; Benjamin Henninger; Christina Tiller; Magdalena Holzknecht; Christian Kremser; Axel Bauer; Werner Jaschke; Bernhard Metzler; Agnes Mayr
Journal:  Eur Radiol       Date:  2020-04-22       Impact factor: 5.315

10.  "Push-button" noncontrast MR angiography using balanced T1 relaxation-enhanced steady-state (bT1RESS).

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  Magn Reson Med       Date:  2020-09-16       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.