Literature DB >> 25681949

Hemodialysis vascular access stenosis detection using auditory spectro-temporal features of phonoangiography.

Po-Hsun Sung1, Chung-Dann Kan, Wei-Ling Chen, Ling-Sheng Jang, Jhing-Fa Wang.   

Abstract

For end-stage renal disease patients undergoing hemodialysis, thrombosis caused by stenosis hinders the long-term use of vascular access. However, traditional spectral bruit analysis techniques for detecting the severity of vascular access stenosis are not robust. Accordingly, the present study proposes an automated method for mimicking a trained practitioner in performing the auscultation process. In the proposed approach, the bruit obtained using a standard phonoangiographic method is transformed into the time-frequency domain, and two spectro-temporal features, namely the auditory spectrum flux and the auditory spectral centroid, are then extracted. The distributions of the two features are analyzed using a multivariate Gaussian distribution (MGD) model. Finally, the distribution parameters of the MGD model are used to detect the presence (or otherwise) of vascular access stenosis. The validity of the proposed approach is investigated using the phonoangiography signals obtained from 16 hemodialysis patients with straight arteriovenous grafts over the upper arm region. The results show that the MGD covariance matrix coefficient of the auditory spectral centroid feature yields an accuracy of 83.87 % in detecting significant vascular access stenosis. Thus, the proposed method has significant potential for the applications of vascular access stenosis detection.

Entities:  

Mesh:

Year:  2015        PMID: 25681949     DOI: 10.1007/s11517-014-1241-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  26 in total

1.  Prospective evaluation of carotid artery stenosis: elliptic centric contrast-enhanced MR angiography and spiral CT angiography compared with digital subtraction angiography.

Authors:  Juan Alvarez-Linera; Julián Benito-León; José Escribano; Jorge Campollo; Ricardo Gesto
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

2.  Feature extraction from parametric time-frequency representations for heart murmur detection.

Authors:  L D Avendaño-Valencia; J I Godino-Llorente; M Blanco-Velasco; G Castellanos-Dominguez
Journal:  Ann Biomed Eng       Date:  2010-06-02       Impact factor: 3.934

3.  Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access.

Authors:  H A Mansy; S J Hoxie; N H Patel; R H Sandler
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

Review 4.  Hemodialysis vascular access morbidity.

Authors:  H I Feldman; S Kobrin; A Wasserstein
Journal:  J Am Soc Nephrol       Date:  1996-04       Impact factor: 10.121

5.  Phonoangiography by autocorrelation.

Authors:  R M Rosen; S P Parthasarathy; A F Turner; D H Blankenhorn; E J Roschke
Journal:  Circulation       Date:  1977-04       Impact factor: 29.690

6.  Phonoangiography: qualitative and quantitative.

Authors:  R S Lees
Journal:  Ann Biomed Eng       Date:  1984       Impact factor: 3.934

7.  Quantitative carotid phonoangiography.

Authors:  R Knox; P Breslau; D E Strandness
Journal:  Stroke       Date:  1981 Nov-Dec       Impact factor: 7.914

8.  A coupled flow-acoustic computational study of bruits from a modeled stenosed artery.

Authors:  Jung Hee Seo; Rajat Mittal
Journal:  Med Biol Eng Comput       Date:  2012-05-21       Impact factor: 2.602

9.  Vascular access stenosis: comparison of arteriovenous grafts and fistulas.

Authors:  Ivan D Maya; Rachel Oser; Souheil Saddekni; Jill Barker; Michael Allon
Journal:  Am J Kidney Dis       Date:  2004-11       Impact factor: 8.860

10.  Noninvasive detection of coronary artery disease using parametric spectral analysis methods.

Authors:  J L Semmlow; M Akay; W Welkowitz
Journal:  IEEE Eng Med Biol Mag       Date:  1990
View more
  7 in total

1.  Effect of stenosis shape on the sound emitted from a constricted blood vessel.

Authors:  Kamil Ozden; Cuneyt Sert; Yigit Yazicioglu
Journal:  Med Biol Eng Comput       Date:  2020-01-14       Impact factor: 2.602

2.  Flexible, Skin Coupled Microphone Array for Point of Care Vascular Access Monitoring.

Authors:  Binit Panda; Soumyajit Mandal; Steve J A Majerus
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-18       Impact factor: 3.833

3.  Bilateral photoplethysmography for arterial steal detection in arteriovenous fistula using a fractional-order decision-making quantizer.

Authors:  Jian-Xing Wu; Guan-Chun Chen; Ming-Jui Wu; Chia-Hung Lin; Tainsong Chen
Journal:  Med Biol Eng Comput       Date:  2016-05-06       Impact factor: 2.602

4.  Bruit-enhancing phonoangiogram filter using sub-band autoregressive linear predictive coding.

Authors:  Steve J A Majerus; Thomas Knauss; Soumyajit Mandal; Geoff Vince; Margot S Damaser
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

5.  Stenosis Characterization and Identification for Dialysis Vascular Access.

Authors:  S Chin; B Panda; M S Damaser; S J A Majerus
Journal:  IEEE Signal Process Med Biol Symp       Date:  2019-01-17

6.  Quantification and Visualization of Reliable Hemodynamics Evaluation Based on Non-Contact Arteriovenous Fistula Measurement.

Authors:  Rumi Iwai; Takunori Shimazaki; Yoshifumi Kawakubo; Kei Fukami; Shingo Ata; Takeshi Yokoyama; Takashi Hitosugi; Aki Otsuka; Hiroyuki Hayashi; Masanobu Tsurumoto; Reiko Yokoyama; Tetsuya Yoshida; Shinya Hirono; Daisuke Anzai
Journal:  Sensors (Basel)       Date:  2022-04-02       Impact factor: 3.576

7.  The prototype device for non-invasive diagnosis of arteriovenous fistula condition using machine learning methods.

Authors:  Marcin Grochowina; Lucyna Leniowska; Agnieszka Gala-Błądzińska
Journal:  Sci Rep       Date:  2020-10-02       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.