Literature DB >> 27154237

Bilateral photoplethysmography for arterial steal detection in arteriovenous fistula using a fractional-order decision-making quantizer.

Jian-Xing Wu1, Guan-Chun Chen1, Ming-Jui Wu2, Chia-Hung Lin3, Tainsong Chen4.   

Abstract

As inflow and outflow stenoses worsen, both flow resistance and pressure increase in the stenotic vascular access. During dialysis, when blood flow decreases, it may retrograde from the peripheral artery through the palmar arch to the arterial anastomosis site. Arterial steal syndrome (ASS) causes distal hypoperfusion, resulting in hand ischemia or extremity pain and edema. Hence, this study proposes the bilateral photoplethysmography (PPG) for ASS detection in arteriovenous fistulas. The decision-making quantizer utilizes the fractional-order feature extraction method and a non-cooperative game (NCG) framework to evaluate the ASS risk level. Bilateral asynchronous PPG signals have significant differences in the rise time and amplitude in relation to the degree of stenosis. The fractional-order self-synchronization error formulation is a feature extraction method used to quantify bilateral differences in blood flow changes between the dexter and sinister PPG signals. The NCG model as a method of decision-making is then employed to evaluate the ASS risk level. Using an acoustic Doppler measurement, the resistive (Res) index is also used to evaluate the vascular access stenosis at the arterial anastomosis site. In contrast with alternative methods including the high-sensitivity C-reactive protein level or Res index, our experimental results indicate that the proposed decision-making quantizer is more efficient in preventing ASS during hemodialysis treatment.

Entities:  

Keywords:  Arterial steal syndrome (ASS); Fractional-order self-synchronization error formulation; Non-cooperative game (NCG); Photoplethysmography (PPG)

Mesh:

Year:  2016        PMID: 27154237     DOI: 10.1007/s11517-016-1503-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  23 in total

Review 1.  Clinical application of C-reactive protein for cardiovascular disease detection and prevention.

Authors:  Paul M Ridker
Journal:  Circulation       Date:  2003-01-28       Impact factor: 29.690

Review 2.  C-reactive protein in atherosclerosis: A causal factor?

Authors:  Elaine Paffen; Moniek P M DeMaat
Journal:  Cardiovasc Res       Date:  2006-03-13       Impact factor: 10.787

3.  Design of a continuous-wave Doppler ultrasonic flowmeter for perivascular application. Part 2. Signal processing system.

Authors:  D Cowan; A L Stevens; V C Roberts
Journal:  Med Biol Eng Comput       Date:  1988-03       Impact factor: 2.602

4.  Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics.

Authors:  John Allen; Crispian P Oates; Timothy A Lees; Alan Murray
Journal:  Physiol Meas       Date:  2005-07-06       Impact factor: 2.833

5.  Hemodialysis vascular access stenosis detection using auditory spectro-temporal features of phonoangiography.

Authors:  Po-Hsun Sung; Chung-Dann Kan; Wei-Ling Chen; Ling-Sheng Jang; Jhing-Fa Wang
Journal:  Med Biol Eng Comput       Date:  2015-02-15       Impact factor: 2.602

6.  Right-left correlation of the sympathetically induced fluctuations of photoplethysmographic signal in diabetic and non-diabetic subjects.

Authors:  A Buchs; Y Slovik; M Rapoport; C Rosenfeld; B Khanokh; M Nitzan
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

7.  C-reactive protein makes human endothelium stiff and tight.

Authors:  Kristina Kusche-Vihrog; Katarina Urbanova; Anja Blanqué; Marianne Wilhelmi; Hermann Schillers; Katrin Kliche; Hermann Pavenstädt; Eva Brand; Hans Oberleithner
Journal:  Hypertension       Date:  2010-12-13       Impact factor: 10.190

Review 8.  Upper extremity ischemia and hemodialysis vascular access.

Authors:  J H M Tordoir; R Dammers; F M van der Sande
Journal:  Eur J Vasc Endovasc Surg       Date:  2004-01       Impact factor: 7.069

9.  Bilateral photoplethysmography analysis for arteriovenous fistula dysfunction screening with fractional-order feature and cooperative game-based embedded detector.

Authors:  Jian-Xing Wu; Chia-Hung Lin; Ming-Jui Wu; Chien-Ming Li; Bee-Yen Lim; Yi-Chun Du
Journal:  Healthc Technol Lett       Date:  2015-05-01

10.  Caring for Patients with CRF: Rewards and Benefits.

Authors:  Ayman Karkar
Journal:  Int J Nephrol       Date:  2011-04-07
View more
  1 in total

Review 1.  Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review.

Authors:  Malak Abdullah Almarshad; Md Saiful Islam; Saad Al-Ahmadi; Ahmed S BaHammam
Journal:  Healthcare (Basel)       Date:  2022-03-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.