Literature DB >> 25680629

Ultralow-dose computed tomography imaging for surgery of midfacial and orbital fractures using ASIR and MBIR.

G Widmann1, D Dalla Torre2, R Hoermann3, P Schullian4, E M Gassner4, R Bale4, W Puelacher2.   

Abstract

The influence of dose reductions on diagnostic quality using a series of high-resolution ultralow-dose computed tomography (CT) scans for computer-assisted planning and surgery including the most recent iterative reconstruction algorithms was evaluated and compared with the fracture detectability of a standard cranial emergency protocol. A human cadaver head including the mandible was artificially prepared with midfacial and orbital fractures and scanned using a 64-multislice CT scanner. The CT dose index volume (CTDIvol) and effective doses were calculated using application software. Noise was evaluated as the standard deviation in Hounsfield units within an identical region of interest in the posterior fossa. Diagnostic quality was assessed by consensus reading of a craniomaxillofacial surgeon and radiologist. Compared with the emergency protocol at CTDIvol 35.3 mGy and effective dose 3.6 mSv, low-dose protocols down to CTDIvol 1.0 mGy and 0.1 mSv (97% dose reduction) may be sufficient for the diagnosis of dislocated craniofacial fractures. Non-dislocated fractures may be detected at CTDIvol 2.6 mGy and 0.3 mSv (93% dose reduction). Adaptive statistical iterative reconstruction (ASIR) 50 and 100 reduced average noise by 30% and 56%, and model-based iterative reconstruction (MBIR) by 93%. However, the detection rate of fractures could not be improved due to smoothing effects. Crown
Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  computed tomography; iterative reconstructions; low dose; traumatology

Mesh:

Year:  2015        PMID: 25680629     DOI: 10.1016/j.ijom.2015.01.011

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  15 in total

1.  Ultralow dose dentomaxillofacial CT imaging and iterative reconstruction techniques: variability of Hounsfield units and contrast-to-noise ratio.

Authors:  Gerlig Widmann; Alexander Bischel; Andreas Stratis; Apoorv Kakar; Hilde Bosmans; Reinhilde Jacobs; Eva-Maria Gassner; Wolfgang Puelacher; Ruben Pauwels
Journal:  Br J Radiol       Date:  2016-01-21       Impact factor: 3.039

2.  Spatial and contrast resolution of ultralow dose dentomaxillofacial CT imaging using iterative reconstruction technology.

Authors:  Gerlig Widmann; Alexander Bischel; Andreas Stratis; Hilde Bosmans; Reinhilde Jacobs; Eva-Maria Gassner; Wolfgang Puelacher; Ruben Pauwels
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

3.  Accuracy of computer-aided design models of the jaws produced using ultra-low MDCT doses and ASIR and MBIR.

Authors:  Asma'a A Al-Ekrish; Sara A Alfadda; Wadea Ameen; Romed Hörmann; Wolfgang Puelacher; Gerlig Widmann
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-16       Impact factor: 2.924

Review 4.  New and emerging patient-centered CT imaging and image-guided treatment paradigms for maxillofacial trauma.

Authors:  David Dreizin; Arthur J Nam; Jeffrey Hirsch; Mark P Bernstein
Journal:  Emerg Radiol       Date:  2018-06-20

5.  Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIR.

Authors:  Asma'a A Al-Ekrish; Reema Al-Shawaf; Peter Schullian; Ra'ed Al-Sadhan; Romed Hörmann; Gerlig Widmann
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-02       Impact factor: 2.924

6.  Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

Authors:  Gerlig Widmann; Reema Al-Shawaf; Peter Schullian; Ra'ed Al-Sadhan; Romed Hörmann; Asma'a A Al-Ekrish
Journal:  Eur Radiol       Date:  2016-09-21       Impact factor: 5.315

7.  Investigation of the efficacy of a data-driven CT artifact correction scheme for sparse and truncated projection data for intracranial hemorrhage diagnosis.

Authors:  Alexander R Podgorsak; Mohammad Mahdi Shiraz Bhurwani; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

8.  Application of a full model-based iterative reconstruction (MBIR) in 80 kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients.

Authors:  Jihang Sun; Qifeng Zhang; Xiaomin Duan; Chengyue Zhang; Pengpeng Wang; Chenguang Jia; Yong Liu; Yun Peng
Journal:  Radiol Med       Date:  2017-10-10       Impact factor: 3.469

9.  Diagnostic reliability of low dose multidetector CT and cone beam CT in maxillofacial trauma-an experimental blinded and randomized study.

Authors:  Romke Rozema; Michiel Hj Doff; Peter Ma van Ooijen; Douwe Postmus; Henriëtte E Westerlaan; Martijn F Boomsma; Baucke van Minnen
Journal:  Dentomaxillofac Radiol       Date:  2018-05-31       Impact factor: 2.419

Review 10.  Diagnostic accuracy of physical examination findings for midfacial fractures: a systematic review and meta-analysis.

Authors:  Romke Rozema; Michiel H J Doff; Konstantina Delli; Frederik K L Spijkervet; Baucke van Minnen
Journal:  Clin Oral Investig       Date:  2022-03-17       Impact factor: 3.573

View more