Literature DB >> 25654667

Intravenous Iodinated Contrast Agents Amplify DNA Radiation Damage at CT.

Eike I Piechowiak1, Jan-Friedrich W Peter, Beate Kleb, Klaus J Klose, Johannes T Heverhagen.   

Abstract

PURPOSE: To determine the effect of the use of iodinated contrast agents on the formation of DNA double-strand breaks during chest computed tomography (CT).
MATERIALS AND METHODS: This study was approved by the institutional review board, and written informed consent was obtained from all patients. This single-center study was performed at a university hospital. A total of 179 patients underwent contrast material-enhanced CT, and 66 patients underwent unenhanced CT. Blood samples were taken from these patients prior to and immediately after CT. In these blood samples, the average number of phosphorylated histone H2AX (γH2AX) foci per lymphocyte was determined with fluorescence microscopy. Significant differences between the number of foci that developed in both the presence and the absence of the contrast agent were tested by using an independent sample t test.
RESULTS: γH2AX foci levels were increased in both groups after CT. Patients who underwent contrast-enhanced CT had an increased amount of DNA radiation damage (mean increase ± standard error of the mean, 0.056 foci per cell ± 0.009). This increase was 107% ± 19 higher than that in patients who underwent unenhanced CT (mean increase, 0.027 foci per cell ± 0.014).
CONCLUSION: The application of iodinated contrast agents during diagnostic x-ray procedures, such as chest CT, leads to a clear increase in the level of radiation-induced DNA damage as assessed with γH2AX foci formation. RSNA, 2015

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25654667     DOI: 10.1148/radiol.14132478

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  24 in total

Review 1.  Does iodinated contrast medium amplify DNA damage during exposure to radiation.

Authors:  Peter Riley
Journal:  Br J Radiol       Date:  2015-08-03       Impact factor: 3.039

2.  Cardiac MR Imaging and the Specter of Double-Strand Breaks.

Authors:  Amy Berrington de Gonzalez; Ruth A Kleinerman; Dorothea McAreavey; Preetha Rajaraman
Journal:  Radiology       Date:  2015-11       Impact factor: 11.105

Review 3.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

4.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

5.  CT Scanning: Is the Contrast Material Enhancing the Radiation Dose and Cancer Risk as Well as the Image?

Authors:  Amy Berrington de Gonzalez; Ruth A Kleinerman
Journal:  Radiology       Date:  2015-06       Impact factor: 11.105

6.  Improved identification of DNA double strand breaks: γ-H2AX-epitope visualization by confocal microscopy and 3D reconstructed images.

Authors:  Nico Ruprecht; Martin N Hungerbühler; Ingrid B Böhm; Johannes T Heverhagen
Journal:  Radiat Environ Biophys       Date:  2019-02-24       Impact factor: 1.925

7.  Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology.

Authors:  Prabhakar Rajiah; Leslie Ciancibello; Ronald Novak; Jennifer Sposato; Luis Landeras; Robert Gilkeson
Journal:  Diagn Interv Radiol       Date:  2019-05       Impact factor: 2.630

8.  High-pitch CT, decreasing need for sedation and its potential side effects: some practical considerations and future directions.

Authors:  Sjirk J Westra
Journal:  Pediatr Radiol       Date:  2018-12-10

9.  A prospective evaluation of contrast and radiation dose and image quality in cardiac CT in children with complex congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current.

Authors:  Qiao-Ru Hou; Wei Gao; Ai-Min Sun; Qian Wang; Hai-Sheng Qiu; Fang Wang; Li-Wei Hu; Jian-Ying Li; Yu-Min Zhong
Journal:  Br J Radiol       Date:  2016-12-07       Impact factor: 3.039

10.  The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms.

Authors:  Pooyan Sahbaee; W Paul Segars; Daniele Marin; Rendon C Nelson; Ehsan Samei
Journal:  Radiology       Date:  2017-01-13       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.