Literature DB >> 25644073

Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve.

Bradley D Allen1, Pim van Ooij1, Alex J Barker1, Maria Carr1, Maya Gabbour2, Susanne Schnell1, Kelly B Jarvis1, James C Carr1, Michael Markl1,3, Cynthia Rigsby2, Joshua D Robinson4,5.   

Abstract

BACKGROUND: To evaluate the 3D hemodynamics in the thoracic aorta of pediatric and young adult bicuspid aortic valve (BAV) patients.
METHODS: 4D flow MRI was performed in 30 pediatric and young adult BAV patients (age: 13.9 ± 4.4 (range: [3.4, 20.7]) years old, M:F = 17:13) as part of this Institutional Review Board-approved study. Nomogram-based aortic root Z-scores were calculated to assess aortic dilatation and degree of aortic stenosis (AS) severity was assessed on MRI. Data analysis included calculation of time-averaged systolic 3D wall shear stress (WSSsys ) along the entire aorta wall, and regional quantification of maximum and mean WSSsys and peak systolic velocity (velsys ) in the ascending aorta (AAo), arch, and descending aorta (DAo). The 4D flow MRI AAo velsys was also compared with echocardiography peak velocity measurements.
RESULTS: There was a positive correlation with both mean and max AAo WSSsys and peak AAo velsys (mean: r = 0.84, P < 0.001, max: r = 0.94, P < 0.001) and AS (mean: rS  = 0.43, P = 0.02, max: rS  = 0.70, P < 0.001). AAo peak velocity was significantly higher when measured with echo compared with 4D flow MRI (2.1 ± 0.98 m/s versus 1.27 ± 0.49 m/s, P < 0.001).
CONCLUSION: In pediatric and young adult patients with BAV, AS and peak ascending aorta velocity are associated with increased AAo WSS, while aortic dilation, age, and body surface area do not significantly impact AAo hemodynamics. Prospective studies are required to establish the role of WSS as a risk-stratification tool in these patients.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  4D flow MRI; bicuspid aortic valve; pediatrics; wall shear stress

Mesh:

Year:  2015        PMID: 25644073      PMCID: PMC4511732          DOI: 10.1002/jmri.24847

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  43 in total

1.  Wall shear stress and flow patterns in the ascending aorta in patients with bicuspid aortic valves differ significantly from tricuspid aortic valves: a prospective study.

Authors:  Christian Meierhofer; Eike Philipp Schneider; Christine Lyko; Andrea Hutter; Stefan Martinoff; Michael Markl; Alfred Hager; John Hess; Heiko Stern; Sohrab Fratz
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-12-09       Impact factor: 6.875

Review 2.  4D flow MRI.

Authors:  Michael Markl; Alex Frydrychowicz; Sebastian Kozerke; Mike Hope; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-11       Impact factor: 4.813

3.  Comparison of blood flow velocity quantification by 4D flow MR imaging with ultrasound at the carotid bifurcation.

Authors:  A Harloff; T Zech; F Wegent; C Strecker; C Weiller; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2013-02-14       Impact factor: 3.825

4.  Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging.

Authors:  Pablo Bächler; Israel Valverde; Natalia Pinochet; Sarah Nordmeyer; Titus Kuehne; Gérard Crelier; Cristián Tejos; Pablo Irarrazaval; Philipp Beerbaum; Sergio Uribe
Journal:  Radiology       Date:  2013-01-07       Impact factor: 11.105

5.  Aortic aneurysms remain a significant source of morbidity and mortality after use of Dacron(®) patch aortoplasty to repair coarctation of the aorta: results from a single center.

Authors:  Jonathan W Cramer; Salil Ginde; Peter J Bartz; James S Tweddell; S Bert Litwin; Michael G Earing
Journal:  Pediatr Cardiol       Date:  2012-07-28       Impact factor: 1.655

6.  Comparison between proximal thoracic vascular measurements obtained by contrast-enhanced magnetic resonance angiography and by transthoracic echocardiography in infants and children with congenital heart disease.

Authors:  Nitin Madan; Jen Lie Yau; Shubhika Srivastava; James C Nielsen
Journal:  Pediatr Cardiol       Date:  2012-08-25       Impact factor: 1.655

7.  Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve.

Authors:  Salvatore Pasta; Antonino Rinaudo; Angelo Luca; Michele Pilato; Cesare Scardulla; Thomas G Gleason; David A Vorp
Journal:  J Biomech       Date:  2013-05-08       Impact factor: 2.712

8.  Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition.

Authors:  Israel Valverde; Sarah Nordmeyer; Sergio Uribe; Gerald Greil; Felix Berger; Titus Kuehne; Philipp Beerbaum
Journal:  J Cardiovasc Magn Reson       Date:  2012-04-27       Impact factor: 5.364

9.  Evaluation of 3D blood flow patterns and wall shear stress in the normal and dilated thoracic aorta using flow-sensitive 4D CMR.

Authors:  Jonas Bürk; Philipp Blanke; Zoran Stankovic; Alex Barker; Maximilian Russe; Julia Geiger; Alex Frydrychowicz; Mathias Langer; Michael Markl
Journal:  J Cardiovasc Magn Reson       Date:  2012-12-13       Impact factor: 5.364

10.  Aortic dilation in bicuspid aortic valve disease: flow pattern is a major contributor and differs with valve fusion type.

Authors:  Malenka M Bissell; Aaron T Hess; Luca Biasiolli; Steffan J Glaze; Margaret Loudon; Alex Pitcher; Anne Davis; Bernard Prendergast; Michael Markl; Alex J Barker; Stefan Neubauer; Saul G Myerson
Journal:  Circ Cardiovasc Imaging       Date:  2013-06-14       Impact factor: 7.792

View more
  14 in total

1.  Abnormal aortic flow conduction is associated with increased viscous energy loss in patients with repaired tetralogy of Fallot.

Authors:  Michal Schäfer; Alex J Barker; James Jaggers; Gareth J Morgan; Matthew L Stone; Uyen Truong; Lorna P Browne; Ladonna Malone; D Dunbar Ivy; Max B Mitchell
Journal:  Eur J Cardiothorac Surg       Date:  2020-03-01       Impact factor: 4.191

2.  Altered 4-D magnetic resonance imaging flow characteristics in complex congenital aortic arch repair.

Authors:  Lajja P Desai; Haben Berhane; Nazia Husain; Joshua D Robinson; Cynthia K Rigsby; Michael Markl
Journal:  Pediatr Radiol       Date:  2019-08-31

3.  Comprehensive MR Analysis of Cardiac Function, Aortic Hemodynamics and Left Ventricular Strain in Pediatric Cohort with Isolated Bicuspid Aortic Valve.

Authors:  Heather A Stefek; Haben Berhane; Joshua D Robinson; Brian Reilly; Alexander Ruh; Michael Markl; Cynthia K Rigsby
Journal:  Pediatr Cardiol       Date:  2019-07-24       Impact factor: 1.655

4.  Impact of different coarctation therapies on aortic stiffness: phase-contrast MRI study.

Authors:  Michal Schäfer; Gareth J Morgan; Max B Mitchell; Michael Ross; Alex J Barker; Kendall S Hunter; Brian Fonseca; Michael DiMaria; Daniel Vargas; D Dunbar Ivy; Neil Wilson; Lorna P Browne
Journal:  Int J Cardiovasc Imaging       Date:  2018-04-17       Impact factor: 2.357

5.  Enhanced 4D Flow MRI-Based CFD with Adaptive Mesh Refinement for Flow Dynamics Assessment in Coarctation of the Aorta.

Authors:  Labib Shahid; James Rice; Haben Berhane; Cynthia Rigsby; Joshua Robinson; Lindsay Griffin; Michael Markl; Alejandro Roldán-Alzate
Journal:  Ann Biomed Eng       Date:  2022-05-27       Impact factor: 3.934

6.  Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome.

Authors:  Raoul Arnold; Marie Neu; Daniel Hirtler; Charlotte Gimpel; Michael Markl; Julia Geiger
Journal:  Pediatr Radiol       Date:  2017-02-09

Review 7.  4D flow MRI applications in congenital heart disease.

Authors:  Judy Rizk
Journal:  Eur Radiol       Date:  2020-09-01       Impact factor: 5.315

8.  4-D flow MRI aortic 3-D hemodynamics and wall shear stress remain stable over short-term follow-up in pediatric and young adult patients with bicuspid aortic valve.

Authors:  Michael J Rose; Cynthia K Rigsby; Haben Berhane; Emilie Bollache; Kelly Jarvis; Alex J Barker; Susanne Schnell; Bradley D Allen; Joshua D Robinson; Michael Markl
Journal:  Pediatr Radiol       Date:  2018-09-10

Review 9.  Additional value and new insights by four-dimensional flow magnetic resonance imaging in congenital heart disease: application in neonates and young children.

Authors:  Julia Geiger; Fraser M Callaghan; Barbara E U Burkhardt; Emanuela R Valsangiacomo Buechel; Christian J Kellenberger
Journal:  Pediatr Radiol       Date:  2020-12-11

10.  Four-Dimensional flow Magnetic Resonance Imaging for Assessment of Pediatric Coarctation of the Aorta.

Authors:  Lajja Desai; Heather Stefek; Haben Berhane; Joshua Robinson; Cynthia Rigsby; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2021-06-26       Impact factor: 5.119

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.