Literature DB >> 22923009

Comparison between proximal thoracic vascular measurements obtained by contrast-enhanced magnetic resonance angiography and by transthoracic echocardiography in infants and children with congenital heart disease.

Nitin Madan1, Jen Lie Yau, Shubhika Srivastava, James C Nielsen.   

Abstract

Accurate assessment of the proximal thoracic vasculature in infants and children with congenital heart disease (CHD) is vital for deciding the appropriate surgical or interventional procedure and predicting outcomes. This information usually is obtained by transthoracic echocardiography (TTE). Contrast-enhanced magnetic resonance angiography (CE-MRA) frequently is used to obtain diagnostic data when the image quality by TTE is limited. Calculation of z-scores for measurements obtained by CE-MRA in this population currently is not possible due to the lack of normative data. A reasonable agreement between vessel dimensions by CE-MRA and TTE will allow the use of TTE-based z-scores on measurements from CE-MRA. This study examines the accuracy and agreement of proximal thoracic vascular measurements obtained by CE-MRA versus TTE. Infants and children younger than 3 years with CHD who had a CE-MRA between August 2006 and May 2011 were retrospectively identified. Main and branch pulmonary arteries, ascending aorta, distal transverse arch, and aortic isthmus were measured from CE-MRA and TTE in analogous imaging planes and locations by two investigators blinded to each other. The study enrolled 35 subjects with CHD. The median age was 129 days (range, 0-1077 days), and the median weight was 5.8 kg (range, 2.16-17 kg). The median interval between the two imaging methods was 9 days (range, 0-60 days). Data analysis was performed with 129 of the 210 possible paired measurements. The remaining 81 paired measurements could not be performed due to inaccurate visualization of vessel borders or an unavailable imaging plane from TTE, CE-MRA, or both. The range of vessel sizes measured from 2.8 to 23.4 mm. There was excellent correlation between CE-MRA and TTE (r = 0.94, p < 0.001). The mean difference between the measurements was -0.1 ± 1.2 mm, and the limits of agreement were -2.5 to 2.3 mm. Proximal thoracic vascular measurements obtained by CE-MRA and TTE in infants and children with CHD have a strong correlation. The agreement between these two imaging methods is adequate. Until normative data for vessel size measurements obtained from CE-MRA are available for this population, TTE-based z-scores can be applied to the measurements obtained by CE-MRA.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22923009     DOI: 10.1007/s00246-012-0480-8

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  21 in total

Review 1.  Assessment of cardiovascular anatomy in patients with congenital heart disease by magnetic resonance imaging.

Authors:  T Chung
Journal:  Pediatr Cardiol       Date:  2000 Jan-Feb       Impact factor: 1.655

Review 2.  Morphologic and functional evaluation of congenital heart disease by magnetic resonance imaging.

Authors:  D Didier; O Ratib; M Beghetti; I Oberhaensli; B Friedli
Journal:  J Magn Reson Imaging       Date:  1999-11       Impact factor: 4.813

3.  Operator-independent isotropic three-dimensional magnetic resonance imaging for morphology in congenital heart disease: a validation study.

Authors:  Thomas Sangild Sørensen; Hermann Körperich; Gerald F Greil; Joachim Eichhorn; Peter Barth; Hans Meyer; Erik Morre Pedersen; Philipp Beerbaum
Journal:  Circulation       Date:  2004-06-21       Impact factor: 29.690

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Relationship of the dimension of cardiac structures to body size: an echocardiographic study in normal infants and children.

Authors:  P E Daubeney; E H Blackstone; R G Weintraub; Z Slavik; J Scanlon; S A Webber
Journal:  Cardiol Young       Date:  1999-07       Impact factor: 1.093

6.  Early and intermediate outcomes after repair of pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries: experience with 85 patients.

Authors:  V M Reddy; D B McElhinney; Z Amin; P Moore; A J Parry; D F Teitel; F L Hanley
Journal:  Circulation       Date:  2000-04-18       Impact factor: 29.690

7.  Gadolinium-enhanced 3-dimensional magnetic resonance angiography of pulmonary blood supply in patients with complex pulmonary stenosis or atresia: comparison with x-ray angiography.

Authors:  Tal Geva; Gerald F Greil; Audrey C Marshall; Michael Landzberg; Andrew J Powell
Journal:  Circulation       Date:  2002-07-23       Impact factor: 29.690

8.  Surgical management of neonatal coarctation.

Authors:  S Conte; F Lacour-Gayet; A Serraf; M Sousa-Uva; J Bruniaux; A Touchot; C Planché
Journal:  J Thorac Cardiovasc Surg       Date:  1995-04       Impact factor: 5.209

9.  Regression equations for calculation of z scores of cardiac structures in a large cohort of healthy infants, children, and adolescents: an echocardiographic study.

Authors:  Michael D Pettersen; Wei Du; Mary Ellen Skeens; Richard A Humes
Journal:  J Am Soc Echocardiogr       Date:  2008-04-11       Impact factor: 5.251

10.  Noncontrast 3D steady-state free-precession magnetic resonance angiography of the whole chest using nonselective radiofrequency excitation over a large field of view: comparison with single-phase 3D contrast-enhanced magnetic resonance angiography.

Authors:  Mayil S Krishnam; Anderanik Tomasian; Vibhas Deshpande; Lien Tran; Gerhard Laub; J Paul Finn; Stefan G Ruehm
Journal:  Invest Radiol       Date:  2008-06       Impact factor: 6.016

View more
  2 in total

1.  Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve.

Authors:  Bradley D Allen; Pim van Ooij; Alex J Barker; Maria Carr; Maya Gabbour; Susanne Schnell; Kelly B Jarvis; James C Carr; Michael Markl; Cynthia Rigsby; Joshua D Robinson
Journal:  J Magn Reson Imaging       Date:  2015-01-22       Impact factor: 4.813

2.  Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging.

Authors:  Joyce T Johnson; Joshua D Robinson; Jie Deng; Cynthia K Rigsby
Journal:  Pediatr Radiol       Date:  2016-08-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.