Literature DB >> 25642151

Self-Registration Methods for Increasing Membrane Utilization within Compression-Sealed Microchannel Hemodialysers.

Brian K Paul1, Spencer D Porter1.   

Abstract

More than 1.2 million people worldwide require regular hemodialysis therapy to treat end stage renal failure. Current hemodialysis systems are too expensive to support at-home hemodialysis where more frequent and longer duration treatment can lead to better patient outcomes. The key cost driver for hemodialysers is the cost of the hemodialysis membrane. Microchannel hemodialysers are smaller providing the potential to use significantly less membrane. Prior work has demonstrated the use of sealing bosses to form compression seals in microchannel hemodialysers. In this paper, estimates show that the percentage of the membrane utilized for mass transfer is highly dependent on the design and registration accuracy of adjacent blood and dialysate laminae. Efforts here focus on the development of a self-registration method to align polycarbonate laminae compatible with compression sealing schemes for membrane separation applications. Self-nesting registration methods were demonstrated with average registration accuracies of 11.4 ± 7.2 μm measured over a 50 mm scale. Analysis shows that the registration accuracy is constrained by tolerances in the embossing process. A dialysis test article was produced using the self-nesting registration method showing a measured average one-dimensional misregistration of 18.5 μm allowing a potential 41.4% of the membrane to be utilized for mass transfer when considering both microchannel and header regions. Mass transfer results provide evidence of a twofold to threefold increase in membrane utilization over other designs in the existing literature.

Entities:  

Keywords:  Compression Sealing; Hemodialysis; Membrane; Microchannel; Self-Registration

Year:  2014        PMID: 25642151      PMCID: PMC4307849          DOI: 10.1016/j.jmapro.2014.08.001

Source DB:  PubMed          Journal:  J Manuf Process        ISSN: 1526-6125            Impact factor:   5.010


  11 in total

1.  Nightly home hemodialysis: improvement in nutrition and quality of life.

Authors:  L L McPhatter; R S Lockridge; J Albert; H Anderson; V Craft; F M Jennings; M Spencer; A Swafford; T Barger; L Coffey
Journal:  Adv Ren Replace Ther       Date:  1999-10

2.  New Colorimetric reaction for end-point, continuous-flow, and kinetic measurement of urea.

Authors:  D Jung; H Biggs; J Erikson; P U Ledyard
Journal:  Clin Chem       Date:  1975-07       Impact factor: 8.327

3.  Analysis of pressure-driven air bubble elimination in a microfluidic device.

Authors:  Joo H Kang; Yu Chang Kim; Je-Kyun Park
Journal:  Lab Chip       Date:  2007-10-25       Impact factor: 6.799

4.  Hemodialysis treatment time: a fresh perspective.

Authors:  Eduardo Lacson; Steven M Brunelli
Journal:  Clin J Am Soc Nephrol       Date:  2011-09-01       Impact factor: 8.237

5.  ESRD patients in 2004: global overview of patient numbers, treatment modalities and associated trends.

Authors:  Aileen Grassmann; Simona Gioberge; Stefan Moeller; Gail Brown
Journal:  Nephrol Dial Transplant       Date:  2005-10-04       Impact factor: 5.992

6.  Urea separation in flat-plate microchannel hemodialyzer; experiment and modeling.

Authors:  Alana R Tuhy; Eric K Anderson; Goran N Jovanovic
Journal:  Biomed Microdevices       Date:  2012-06       Impact factor: 2.838

Review 7.  Uremic toxicity: urea and beyond.

Authors:  T A Depner
Journal:  Semin Dial       Date:  2001 Jul-Aug       Impact factor: 3.455

8.  Calcium and phosphate balance with quotidian hemodialysis.

Authors:  Robert M Lindsay; Fayez Alhejaili; Gihad Nesrallah; Rosemary Leitch; Laurie Clement; A Paul Heidenheim; Claude Kortas
Journal:  Am J Kidney Dis       Date:  2003-07       Impact factor: 8.860

9.  Quantitative determination of urea concentrations in cell culture medium.

Authors:  Robert J X Zawada; Peggy Kwan; Kellen L Olszewski; Manuel Llinas; Shu-Gui Huang
Journal:  Biochem Cell Biol       Date:  2009-06       Impact factor: 3.626

Review 10.  What is new in uremic toxicity?

Authors:  Raymond Vanholder; Steven Van Laecke; Griet Glorieux
Journal:  Pediatr Nephrol       Date:  2008-03-07       Impact factor: 3.714

View more
  1 in total

1.  Continuous removal of glycerol from frozen-thawed red blood cells in a microfluidic membrane device.

Authors:  Ratih E Lusianti; Adam Z Higgins
Journal:  Biomicrofluidics       Date:  2014-10-28       Impact factor: 2.800

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.