Literature DB >> 25612627

Validating the Accuracy of Reaction Time Assessment on Computer-Based Tablet Devices.

Philip Schatz1, Vincent Ybarra2, Donald Leitner2.   

Abstract

Computer-based assessment has evolved to tablet-based devices. Despite the availability of tablets and "apps," there is limited research validating their use. We documented timing delays between stimulus presentation and (simulated) touch response on iOS devices (3rd- and 4th-generation Apple iPads) and Android devices (Kindle Fire, Google Nexus, Samsung Galaxy) at response intervals of 100, 250, 500, and 1,000 milliseconds (ms). Results showed significantly greater timing error on Google Nexus and Samsung tablets (81-97 ms), than Kindle Fire and Apple iPads (27-33 ms). Within Apple devices, iOS 7 obtained significantly lower timing error than iOS 6. Simple reaction time (RT) trials (250 ms) on tablet devices represent 12% to 40% error (30-100 ms), depending on the device, which decreases considerably for choice RT trials (3-5% error at 1,000 ms). Results raise implications for using the same device for serial clinical assessment of RT using tablets, as well as the need for calibration of software and hardware.
© The Author(s) 2015.

Entities:  

Keywords:  computer-based assessment; reaction time; timing accuracy

Mesh:

Year:  2015        PMID: 25612627     DOI: 10.1177/1073191114566622

Source DB:  PubMed          Journal:  Assessment        ISSN: 1073-1911


  6 in total

1.  A COMPREHENSIVE INSTRUMENT FOR EVALUATING MILD TRAUMATIC BRAIN INJURY (MTBI)/CONCUSSION IN INDEPENDENT ADULTS: A PILOT STUDY.

Authors:  Amanda Borges; Scot Raab; Monica Lininger
Journal:  Int J Sports Phys Ther       Date:  2017-06

Review 2.  Central nervous system physiology.

Authors:  John Rothwell; Andrea Antal; David Burke; Antony Carlsen; Dejan Georgiev; Marjan Jahanshahi; Dagmar Sternad; Josep Valls-Solé; Ulf Ziemann
Journal:  Clin Neurophysiol       Date:  2021-10-14       Impact factor: 3.708

3.  Development of the Video Analysis Scale of Engagement (VASE) for people with advanced dementia.

Authors:  L L Daniel Lai; Sebastian J Crutch; Julian West; Emma Harding; Emilie V Brotherhood; Rohan Takhar; Nicholas Firth; Paul M Camic
Journal:  Wellcome Open Res       Date:  2021-06-18

4.  MILO Mobile: An iPad App to Measure Search Performance in Multi-Target Sequences.

Authors:  Ian M Thornton; Todd S Horowitz
Journal:  Iperception       Date:  2020-06-20

5.  Evaluating the efficacy of an iPad® app in determining a single bout of exercise benefit to executive function.

Authors:  Benjamin Tari; Matthew Heath
Journal:  Behav Res Methods       Date:  2021-12-16

6.  Mental chronometry in the pocket? Timing accuracy of web applications on touchscreen and keyboard devices.

Authors:  Thomas Pronk; Reinout W Wiers; Bert Molenkamp; Jaap Murre
Journal:  Behav Res Methods       Date:  2020-06
  6 in total