Literature DB >> 25601281

Air exchange rates and migration of VOCs in basements and residences.

L Du1, S Batterman2, C Godwin2, Z Rowe3, J-Y Chin4.   

Abstract

UNLABELLED: Basements can influence indoor air quality by affecting air exchange rates (AERs) and by the presence of emission sources of volatile organic compounds (VOCs) and other pollutants. We characterized VOC levels, AERs, and interzonal flows between basements and occupied spaces in 74 residences in Detroit, Michigan. Flows were measured using a steady-state multitracer system, and 7-day VOC measurements were collected using passive samplers in both living areas and basements. A walk-through survey/inspection was conducted in each residence. AERs in residences and basements averaged 0.51 and 1.52/h, respectively, and had strong and opposite seasonal trends, for example, AERs were highest in residences during the summer, and highest in basements during the winter. Airflows from basements to occupied spaces also varied seasonally. VOC concentration distributions were right-skewed, for example, 90th percentile benzene, toluene, naphthalene, and limonene concentrations were 4.0, 19.1, 20.3, and 51.0 μg/m(3), respectively; maximum concentrations were 54, 888, 1117, and 134 μg/m(3). Identified VOC sources in basements included solvents, household cleaners, air fresheners, smoking, and gasoline-powered equipment. The number and type of potential VOC sources found in basements are significant and problematic, and may warrant advisories regarding the storage and use of potentially strong VOCs sources in basements. PRACTICAL IMPLICATIONS: Few IAQ studies have examined basements. A sizable volume of air can flow between the basement and living area, and AERs in these two zones can differ considerably. In many residences, the basement contains significant emission sources and contributes a large fraction of VOC concentrations found in the living area. Exposures can be lowered by removing VOC sources from the basement; other exposure management options, such as local ventilation or isolation, are unlikely to be practical.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Air exchange rate; Basement; Gasoline; Interzonal flows; Transport; Volatile organic compounds

Mesh:

Substances:

Year:  2015        PMID: 25601281      PMCID: PMC4490136          DOI: 10.1111/ina.12178

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  24 in total

1.  Continuous measurements of air change rates in an occupied house for 1 year: the effect of temperature, wind, fans, and windows.

Authors:  L A Wallace; S J Emmerich; C Howard-Reed
Journal:  J Expo Anal Environ Epidemiol       Date:  2002-07

Review 2.  Diffusive uptake in passive and active adsorbent sampling using thermal desorption tubes.

Authors:  Stuart Batterman; Tricia Metts; Pentti Kalliokoski
Journal:  J Environ Monit       Date:  2002-12

3.  Modeled infiltration rate distributions for U.S. housing.

Authors:  A Persily; A Musser; S J Emmerich
Journal:  Indoor Air       Date:  2010-12       Impact factor: 5.770

4.  Development and comparison of methods using MS scan and selective ion monitoring modes for a wide range of airborne VOCs.

Authors:  Chunrong Jia; Stuart Batterman; Sergei Chernyak
Journal:  J Environ Monit       Date:  2006-10

Review 5.  Organic compounds in office environments - sensory irritation, odor, measurements and the role of reactive chemistry.

Authors:  P Wolkoff; C K Wilkins; P A Clausen; G D Nielsen
Journal:  Indoor Air       Date:  2006-02       Impact factor: 5.770

6.  Differences in source emission rates of volatile organic compounds in inner-city residences of New York City and Los Angeles.

Authors:  Sonja N Sax; Deborah H Bennett; Steven N Chillrud; Patrick L Kinney; John D Spengler
Journal:  J Expo Anal Environ Epidemiol       Date:  2004

7.  The cytotoxic effect of volatile organic compounds of the gas phase of cigarette smoke on lung epithelial cells.

Authors:  Aristea E Pouli; Dimitris G Hatzinikolaou; Christina Piperi; Anastasia Stavridou; Miltiades C Psallidopoulos; John C Stavrides
Journal:  Free Radic Biol Med       Date:  2003-02-01       Impact factor: 7.376

8.  Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles.

Authors:  Stuart Batterman; Chunrong Jia; Gina Hatzivasilis; Chris Godwin
Journal:  J Environ Monit       Date:  2006-01-18

9.  Air change rates and interzonal flows in residences, and the need for multi-zone models for exposure and health analyses.

Authors:  Liuliu Du; Stuart Batterman; Christopher Godwin; Jo-Yu Chin; Edith Parker; Michael Breen; Wilma Brakefield; Thomas Robins; Toby Lewis
Journal:  Int J Environ Res Public Health       Date:  2012-12-12       Impact factor: 3.390

10.  Estimation of bias with the single-zone assumption in measurement of residential air exchange using the perfluorocarbon tracer gas method.

Authors:  K Van Ryswyk; L Wallace; D Fugler; M MacNeill; M È Héroux; M D Gibson; J R Guernsey; W Kindzierski; A J Wheeler
Journal:  Indoor Air       Date:  2014-12-31       Impact factor: 5.770

View more
  5 in total

1.  Factors determining dry deposition of total mercury and organic carbon in house dust of residents of the Tri-city and the surrounding area (Baltic Sea coast).

Authors:  Kinga Wiśniewska; Anita Urszula Lewandowska; Agnieszka Witkowska
Journal:  Air Qual Atmos Health       Date:  2017-04-01       Impact factor: 3.763

2.  SBS symptoms in relation to dampness and ventilation in inspected single-family houses in Sweden.

Authors:  Greta Smedje; Juan Wang; Dan Norbäck; Håkan Nilsson; Karin Engvall
Journal:  Int Arch Occup Environ Health       Date:  2017-06-17       Impact factor: 3.015

Review 3.  Indoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review.

Authors:  Sotiris Vardoulakis; Evanthia Giagloglou; Susanne Steinle; Alice Davis; Anne Sleeuwenhoek; Karen S Galea; Ken Dixon; Joanne O Crawford
Journal:  Int J Environ Res Public Health       Date:  2020-12-02       Impact factor: 3.390

Review 4.  Indoor air quality of everyday use spaces dedicated to specific purposes-a review.

Authors:  Mariusz Marć; Monika Śmiełowska; Jacek Namieśnik; Bożena Zabiegała
Journal:  Environ Sci Pollut Res Int       Date:  2017-11-30       Impact factor: 4.223

Review 5.  A Review of Volatile Organic Compound Contamination in Post-Industrial Urban Centers: Reproductive Health Implications Using a Detroit Lens.

Authors:  Carol J Miller; Melissa Runge-Morris; Andrea E Cassidy-Bushrow; Jennifer K Straughen; Timothy M Dittrich; Tracie R Baker; Michael C Petriello; Gil Mor; Douglas M Ruden; Brendan F O'Leary; Sadaf Teimoori; Chandra M Tummala; Samantha Heldman; Manisha Agarwal; Katherine Roth; Zhao Yang; Bridget B Baker
Journal:  Int J Environ Res Public Health       Date:  2020-11-25       Impact factor: 4.614

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.